Hearth and Home Technologies Cyclone-BC Assemble Slip Sections, Secure the Vent Sections

Page 22

B. Assemble Slip Sections

Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip section over the outer flue of the pipe section. See Figure 8.3.

Slide together to the desired length.

Pilot hole

Figure 8.3 Slip Section Pilot Holes

Maintain a 1-1/2 in. (38 mm) overlap between the slip section and the pipe section.

Secure the pipe and slip section with two screws no longer than 1/2 in. (13 mm), using the pilot holes in the slip section. See Figure 8.4.

Figure 8.4 Screws into Slip Section

Continue adding pipe as necessary following instructions in “Assembling Pipe Sections.”

NOTICE: If slip section is too long, the inner and outer flues of the slip section can be cut to the desired length.

NOTICE: When installing a vent system with an HRC termination cap, all pipe system joints shall be sealed using a high temperature silicone sealant.

Apply a bead of silicone sealant inside the female outer pipe joint prior to joining sections.

Only outer pipes are sealed, sealing the inner flue is not required.

All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed.

C. Secure the Vent Sections

Vertical runs of SLP pipe must be supported every 8 ft. (2.44 m).

Horizontal sections must be supported every 5 feet (1.52 m).

Vent supports or plumbers strap (spaced 120º apart) may be used to support. See Figures 8.5 and 8.6.

Wall shield firestops may be used to provide horizontal support.

SLP ceiling firestops have tabs that may be used to provide vertical support.

WARNING! Risk of Fire, Explosion or Asphyxiation! Improper support may allow vent to sag and separate. Use vent run supports and connect vent sections per in- stallation instructions. DO NOT allow vent to sag below connection point to appliance.

Figure 8.5 Securing Vertical Pipe Sections

Figure 8.6 Securing Horizontal Pipe Sections

22

Heat & Glo • Cyclone-BN, Cyclone-BC2073-900 Rev. N • 10/08

Image 22
Contents What to do if you smell gas Model Cyclone-BN Cyclone-BCHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesModel Constructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow Min MaxTop Vent Horizontal Termination Three Elbows Top Vent Vertical Termination No Elbow Flex VentTop Vent Vertical Termination Two Elbows Three Elbows Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationVertical Penetration Framing Pipe SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Installing Exhaust BaffleSecuring and Leveling the Appliance Installing Vent Pipe Assemble Vent SectionsAssemble Slip Sections Secure the Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 Apply Sealant TOP & Partial SidesInstall Decorative Wall Components Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 22 Venting through the wallGas Pressures Gas InformationFuel Conversions Gas ConnectionHigh Altitude Installations Connecting to the Appliance Recommendation for WireElectrical Information Hot Surface Ignition Wiring Optional Accessories RequirementsFinishing Facing MaterialClean the Appliance Appliance SetupRemove Shipping Materials Glass Assembly Installation AccessoriesRemote Control Service Operating Instructions Before Lighting ApplianceLighting Instructions IPI Turn off all electric power to the applianceFinal inspection by Initial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Fan Motor Service Maintaining and Servicing ApplianceSide Reflector Panel Installation Maintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeter RF4-8 Vent Components DiagramsElbow Roof Flashing Ceiling FirestopAdapter Support Box-BlackBlack Stocked Service PartsAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-BN, Cyclone-BC specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its Cyclone series, which includes the Cyclone-BC and Cyclone-BN models. These wood-burning fireplaces are engineered with cutting-edge technologies that ensure efficient and environmentally friendly heating, making them popular choices for homeowners seeking both functionality and aesthetics.

One of the standout features of the Cyclone series is its innovative air wash system. This technology works to keep the glass panel clean by directing a stream of pre-heated air along the inside surface, effectively reducing the accumulation of soot and ash. As a result, users can enjoy a clear view of the mesmerizing flames without the hassle of constant cleaning.

In terms of efficiency, the Cyclone-BC and Cyclone-BN models boast an exceptional thermal efficiency rating. Thanks to their advanced combustion technology, these fireplaces burn wood more completely, resulting in less smoke and harmful emissions. The high-efficiency design not only benefits the environment but also ensures that heat is maximized, helping to lower heating costs for homeowners.

The construction of the Cyclone fireplaces is another highlight. Built with high-quality materials, these units are designed to withstand the rigors of daily use and maintain their performance over time. Their robust firebox is engineered to accommodate larger logs, offering longer burn times and fewer reloads.

Both models are highly versatile in their aesthetic appeal. The Cyclone-BC features a classic, traditional design that fits seamlessly into a variety of home decors, while the Cyclone-BN leans toward a more contemporary style. Homeowners can customize the look even further with different finishing options, allowing for a personalized touch that complements their unique interior settings.

Safety is paramount in the design of the Cyclone series. These fireplaces come equipped with advanced safety features, including a protective screen and secure door latch, providing peace of mind for families. Additionally, the heat output can be easily controlled, allowing users to adjust the flame and temperature to their desired comfort level.

In conclusion, Hearth and Home Technologies’ Cyclone-BC and Cyclone-BN fireplaces deliver on both performance and style. With efficient heating capabilities, innovative technologies, and a range of design options, these wood-burning units are an exceptional choice for those looking to enhance their living space while enjoying the warmth and ambiance that only a real fire can provide.