Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.

Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.

WARNING

Fire or Explosion Hazard

Gas buildup during line purge may ignite.

Purge should be performed by qualified technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non-corrosive leak check solution. Be sure

to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

WARNING

Fire hazard.

Do NOT change the valve settings.

• This valve has been preset at the factory.

• Changing valve settings may result in fire hazard or bodily injury.

HIGH ALTITUDE INSTALLATIONS

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A., or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

Heat & Glo • Cyclone-BN, Cyclone-BC2073-900 Rev. N • 10/08

29

Image 29
Contents Hot glass will cause burns Model Cyclone-BN Cyclone-BCWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededModel Framing and ClearancesSelecting Appliance Location Clearances Constructing the Appliance ChaseClearances to Mantels or other Combustibles above Appliance Mantel ProjectionsSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Min MaxTop Vent Horizontal Termination Three Elbows Flex Vent Top Vent Vertical Termination No ElbowTop Vent Vertical Termination Two Elbows Three Elbows Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Vertical Penetration FramingVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Securing and Leveling the Appliance Installing Exhaust BaffleAppliance Preparation Assemble Vent Sections Installing Vent PipeSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingApply Sealant TOP & Partial Sides Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components 22 Venting through the wall Install Horizontal Termination CapFuel Conversions Gas InformationGas Pressures Gas ConnectionHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Optional Accessories Requirements Hot Surface Ignition WiringFacing Material FinishingRemove Shipping Materials Glass Assembly Installation Appliance SetupClean the Appliance AccessoriesRemote Control Service Before Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceLighting Instructions IPI After Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintaining and Servicing Appliance Fan Motor ServiceSide Reflector Panel Installation Inspect Maintenance Tasks Maintenance TasksLocation Inches Millimeter Appliance Dimension DiagramReference Materials Elbow Vent Components DiagramsRF4-8 Roof Flashing Ceiling FirestopBlack Support Box-BlackAdapter At Depot Service PartsStocked Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-BN, Cyclone-BC specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its Cyclone series, which includes the Cyclone-BC and Cyclone-BN models. These wood-burning fireplaces are engineered with cutting-edge technologies that ensure efficient and environmentally friendly heating, making them popular choices for homeowners seeking both functionality and aesthetics.

One of the standout features of the Cyclone series is its innovative air wash system. This technology works to keep the glass panel clean by directing a stream of pre-heated air along the inside surface, effectively reducing the accumulation of soot and ash. As a result, users can enjoy a clear view of the mesmerizing flames without the hassle of constant cleaning.

In terms of efficiency, the Cyclone-BC and Cyclone-BN models boast an exceptional thermal efficiency rating. Thanks to their advanced combustion technology, these fireplaces burn wood more completely, resulting in less smoke and harmful emissions. The high-efficiency design not only benefits the environment but also ensures that heat is maximized, helping to lower heating costs for homeowners.

The construction of the Cyclone fireplaces is another highlight. Built with high-quality materials, these units are designed to withstand the rigors of daily use and maintain their performance over time. Their robust firebox is engineered to accommodate larger logs, offering longer burn times and fewer reloads.

Both models are highly versatile in their aesthetic appeal. The Cyclone-BC features a classic, traditional design that fits seamlessly into a variety of home decors, while the Cyclone-BN leans toward a more contemporary style. Homeowners can customize the look even further with different finishing options, allowing for a personalized touch that complements their unique interior settings.

Safety is paramount in the design of the Cyclone series. These fireplaces come equipped with advanced safety features, including a protective screen and secure door latch, providing peace of mind for families. Additionally, the heat output can be easily controlled, allowing users to adjust the flame and temperature to their desired comfort level.

In conclusion, Hearth and Home Technologies’ Cyclone-BC and Cyclone-BN fireplaces deliver on both performance and style. With efficient heating capabilities, innovative technologies, and a range of design options, these wood-burning units are an exceptional choice for those looking to enhance their living space while enjoying the warmth and ambiance that only a real fire can provide.