Hearth and Home Technologies Cyclone-BC Gas Information, Fuel Conversions, Gas Pressures

Page 28

9 Gas Information

A. Fuel Conversions

No fuel conversions allowed.

B. Gas Pressures

Proper input pressures are required for optimum appli- ance performance. Gas line sizing requirements need to be made following NFPA54.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

C. Gas Connection

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Refer to Reference Section 16 for location of gas line access in appliance.

Note: Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2-1/2 inches in diameter and does not penetrate the firebox.

WARNING

Verify inlet pressures.

• High pressure may cause overfire condition.

• Low pressure may cause explosion.

Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other household gas appliances are operating.

Pressure

Natural Gas

Minimum inlet pressure

5.0 inches w.c.

Maximum inlet gas pressure

14.0 inches w.c.

Manifold pressure

3.5 inches w.c.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

Note: The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

28

Heat & Glo • Cyclone-BN, Cyclone-BC2073-900 Rev. N • 10/08

Image 28
Contents What to do if you smell gas Model Cyclone-BN Cyclone-BCHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsDesign and Installation Considerations Getting StartedInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesModel Constructing the Appliance Chase ClearancesMantel Projections Clearances to Mantels or other Combustibles above ApplianceVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Min MaxTop Vent Horizontal Termination Three Elbows Top Vent Vertical Termination No Elbow Flex VentTop Vent Vertical Termination Two Elbows Three Elbows Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Pipe SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Installing Exhaust BaffleSecuring and Leveling the Appliance Installing Vent Pipe Assemble Vent SectionsAssemble Slip Sections Secure the Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 Apply Sealant TOP & Partial SidesInstall Decorative Wall Components Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 22 Venting through the wallGas Information Fuel ConversionsGas Pressures Gas ConnectionHigh Altitude Installations Connecting to the Appliance Recommendation for WireElectrical Information Hot Surface Ignition Wiring Optional Accessories RequirementsFinishing Facing MaterialAppliance Setup Remove Shipping Materials Glass Assembly InstallationClean the Appliance AccessoriesRemote Control Service Operating Instructions Before Lighting ApplianceLighting Instructions IPI Turn off all electric power to the applianceFinal inspection by Initial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Fan Motor Service Maintaining and Servicing ApplianceSide Reflector Panel Installation Maintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeter Vent Components Diagrams ElbowRF4-8 Roof Flashing Ceiling FirestopAdapter Support Box-BlackBlack Stocked Service PartsAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-BN, Cyclone-BC specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its Cyclone series, which includes the Cyclone-BC and Cyclone-BN models. These wood-burning fireplaces are engineered with cutting-edge technologies that ensure efficient and environmentally friendly heating, making them popular choices for homeowners seeking both functionality and aesthetics.

One of the standout features of the Cyclone series is its innovative air wash system. This technology works to keep the glass panel clean by directing a stream of pre-heated air along the inside surface, effectively reducing the accumulation of soot and ash. As a result, users can enjoy a clear view of the mesmerizing flames without the hassle of constant cleaning.

In terms of efficiency, the Cyclone-BC and Cyclone-BN models boast an exceptional thermal efficiency rating. Thanks to their advanced combustion technology, these fireplaces burn wood more completely, resulting in less smoke and harmful emissions. The high-efficiency design not only benefits the environment but also ensures that heat is maximized, helping to lower heating costs for homeowners.

The construction of the Cyclone fireplaces is another highlight. Built with high-quality materials, these units are designed to withstand the rigors of daily use and maintain their performance over time. Their robust firebox is engineered to accommodate larger logs, offering longer burn times and fewer reloads.

Both models are highly versatile in their aesthetic appeal. The Cyclone-BC features a classic, traditional design that fits seamlessly into a variety of home decors, while the Cyclone-BN leans toward a more contemporary style. Homeowners can customize the look even further with different finishing options, allowing for a personalized touch that complements their unique interior settings.

Safety is paramount in the design of the Cyclone series. These fireplaces come equipped with advanced safety features, including a protective screen and secure door latch, providing peace of mind for families. Additionally, the heat output can be easily controlled, allowing users to adjust the flame and temperature to their desired comfort level.

In conclusion, Hearth and Home Technologies’ Cyclone-BC and Cyclone-BN fireplaces deliver on both performance and style. With efficient heating capabilities, innovative technologies, and a range of design options, these wood-burning units are an exceptional choice for those looking to enhance their living space while enjoying the warmth and ambiance that only a real fire can provide.