RHW-41/RHW-47 INSTALLATION INSTRUCTIONS

4. Assemble Chimney Sections

Attach either a straight chimney section or an offset to the top of the fireplace (depending on your installation requirement). Chimney sections are locked together by pushing downward until the top section meets the stop bead on the lower section.

The inner flue is placed to the inside of the flue section below it. The outer casing is placed outside the outer casing of the chimney section below it. See Figure 10.

WARNING!

Carefully follow the instructions for assembly of the pipe and other parts needed to install this fireplace system. Failure to do so may result in a fire, especially if combustibles are too close to the fireplace or chimney and air spaces are blocked, preventing the free movement of cool- ing air.

5. Install Firestop Spacers

Mark and cut out an opening in the ceiling for the firestop spacer being utilized (14-1/2 in. x 14-1/2 in. for an FS338, 14-1/2 in. x 18-3/8 in. for an FS339 and 14-1/2 in. x 23 in. for an FS340). Frame the opening with the same dimension lumber used in the ceiling joists.

Install the firestop spacer.

These firestop spacers are designed to provide the minimum 2 in. air space required around the chimney. In all situations, the firestop spacers are to be nailed to the ceiling joists from the bottom or fireplace side, EXCEPT when the space above is an insulated ceiling or attic space. In this situation, the firestop spacer must be nailed from the top side to prevent loose insulation from falling into the required 2 in. air space around the chimney. See Figure 11.

CAUTION:

Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.

Figure 10

Assembling Chimney

Sections

Figure 11

Installing the Firestop Spacer

16

26022 Rev i

08/04

Image 16
Contents Installation & Operating Instructions Table of Contents Design and Installation Considerations Listings and Code Approvals Description of the Fireplace SystemSystem Components Fireplace ComponentsOutside AIR KIT Chimney Components CAK4AAS8 CAK4A PRE-INSTALLATION Preparation Fireplace Locations and Space RequirementsFraming the Fireplace Framing the FireplaceChimney Requirements Sidewalls/Surrounds Using Offsets and Returns Offset ChartChimney Height Requirements above roof line Number of Sections RequiredInstallation of Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceInstall Firestop Spacers Assemble Chimney SectionsAttic Insulation Shield Double-check the Chimney AssemblySecure the Chimney System Install the Roof Flashing Install the Outside Air KitInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofComplete the Enclosure Gas Log/Lighter ProvisionsHearth Extension Field Constructed Hearth ExtensionPosition the Hearth Extension Finishing MaterialMantel Glass DoorsConstructing a Chase MaterialsChase Top Termination CapInstalling an ST375 Square Termination Cap General Information Outside Air Operating InstructionsFlue Damper Firescreen GrateWood Fuel Draft Problems Starting a FireRHW-41/RHW-47 Installation Instructions Maintenance Instructions Chimney CleaningDisposal of Ashes Creosote and SootHOMEOWNER’S Notes Index Warranty For HEAT-N-GLO Fireplaces