18. Position the Hearth Extension

Position and secure the hearth extension over the protective metal strips that have been placed partially under the fireplace front. These strips should be protruding approximately 2 in. from under the fireplace front and 2 in. on both sides of the fireplace opening. Seal the crack between the hearth extension and fireplace with a bead of noncombustible sealant. See Figure 19. Apply a noncombustible finishing material of your choice to the hearth extension.

Figure 19 - Position the Hearth Extension

19. Finishing Material

Do not install combustible materials over the black face of the fireplace! This poses a safety hazard and may start a fire. You may only use noncombustible material over the black face of the fireplace.

a.Combustible Material

Material which is made of or surfaced with wood, compressed paper, plant fibers, plastics, or any material capable of igniting and burning, whether flame proofed or not, plastered or unplastered.

b.Noncombustible Material

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

c.Noncombustible Sealant Material

Sealants which will not ignite and burn; General Electric RTV103 Black (or equivalent), Rutland, Inc. Fireplace Mortar #63 (or equivalent).

After completing the framing and applying the facing material (dry wall) over the framing, a 1/2 in. wide (maximum) bead of noncombustible sealant must be used to close off any gaps at the top and sides between the fireplace and facing to prevent cold air leaks.

Only noncombustible materials may be used to cover the black metal fireplace front.

20.Mantel

A combustible mantel may be positioned no lower than 12 in. above the top of the fireplace opening. The combustible mantel may have a maximum depth of 12 in. Combustible trim pieces that project no more than 1-1/2 in. from the face of the fireplace can be placed no closer than 6 in. from the top of the fireplace opening. Combustible trim must not cover the black metal surfaces of the fireplace. This mantel clearance is in accordance with Section 7-3.3.3 of ANSI/ NFPA211.

21. Glass Doors

This fireplace has been tested and listed for use with doors as specified in Section C, “System Components”. Please refer to the manual packed with each set of doors for installation instructions.

08/04

26022 Rev i

21

Image 21
Contents Installation & Operating Instructions Table of Contents Design and Installation Considerations Description of the Fireplace System Listings and Code ApprovalsFireplace Components System ComponentsOutside AIR KIT CAK4A Chimney ComponentsAS8 CAK4A Fireplace Locations and Space Requirements PRE-INSTALLATION PreparationFraming the Fireplace Framing the FireplaceSidewalls/Surrounds Chimney RequirementsOffset Chart Using Offsets and ReturnsNumber of Sections Required Chimney Height Requirements above roof linePosition the Fireplace Installation of FireplacePlace the Protective Metal Hearth Strips Level the FireplaceAssemble Chimney Sections Install Firestop SpacersDouble-check the Chimney Assembly Attic Insulation ShieldSecure the Chimney System Install the Outside Air Kit Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofGas Log/Lighter Provisions Complete the EnclosureField Constructed Hearth Extension Hearth ExtensionFinishing Material Position the Hearth ExtensionMantel Glass DoorsMaterials Constructing a ChaseTermination Cap Chase TopInstalling an ST375 Square Termination Cap Operating Instructions General Information Outside AirFlue Damper Grate FirescreenWood Fuel Starting a Fire Draft ProblemsRHW-41/RHW-47 Installation Instructions Chimney Cleaning Maintenance InstructionsDisposal of Ashes Creosote and SootHOMEOWNER’S Notes Index Warranty For HEAT-N-GLO Fireplaces