RHW-41/RHW-47 INSTALLATION INSTRUCTIONS

c.For installations utilizing an ST375 square termination cap the last chimney section must not be more than 4-1/2 in. below the chase top. See Figure 24.

d.For installation utilizing a TS345/TS345P Square Termination Cap, the uppermost chimney section must not be more than 3 in. below the chase top. See Figure 25.

e.Attach the chase top (CT35) to the top of the chase.

f.Install the termination cap, following the instructions provided with it.

Figure 24 - Installing an ST375 Square

Termination Cap

Figure 25 - Installing a TS345/TS345P

Square Termination Cap

WARNING!

Never install a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.

WARNING!

Detailed instructions for installation of the chase top, storm collar and termination cap are packaged with these parts. To avoid danger of fire, all instructions must be strictly followed, including the provision of air space clearance between chimney system and enclosure. To protect against the effects of corrosion on those parts exposed to the weather, we recommend that the chase top and termination cap be painted with a rust- resistant paint.

24

26022 Rev i

08/04

Image 24
Contents Installation & Operating Instructions Table of Contents Design and Installation Considerations Listings and Code Approvals Description of the Fireplace SystemSystem Components Fireplace ComponentsOutside AIR KIT Chimney Components CAK4AAS8 CAK4A PRE-INSTALLATION Preparation Fireplace Locations and Space RequirementsFraming the Fireplace Framing the FireplaceChimney Requirements Sidewalls/SurroundsUsing Offsets and Returns Offset ChartChimney Height Requirements above roof line Number of Sections RequiredInstallation of Fireplace Position the FireplacePlace the Protective Metal Hearth Strips Level the FireplaceInstall Firestop Spacers Assemble Chimney SectionsDouble-check the Chimney Assembly Attic Insulation ShieldSecure the Chimney System Install the Roof Flashing Install the Outside Air KitInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofComplete the Enclosure Gas Log/Lighter ProvisionsHearth Extension Field Constructed Hearth ExtensionPosition the Hearth Extension Finishing MaterialMantel Glass DoorsConstructing a Chase MaterialsChase Top Termination CapInstalling an ST375 Square Termination Cap Operating Instructions General Information Outside AirFlue Damper Grate FirescreenWood Fuel Draft Problems Starting a FireRHW-41/RHW-47 Installation Instructions Maintenance Instructions Chimney CleaningDisposal of Ashes Creosote and SootHOMEOWNER’S Notes Index Warranty For HEAT-N-GLO Fireplaces