Hearth and Home Technologies 8000TVLP-OAKIPI, 8000TV-OAK-IPI owner manual Ues to spark, and main

Page 40

Intellifire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

 

A. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

4. Pilot lights but contin-

sensing rod.

connections underneath pilot assembly are tight. Verify con-

ues to spark, and main

 

nections are not grounding out to metal chassis, pilot burn-

burner will not ignite.

 

er, pilot enclosure or screen if present, or any other metal

(If the pilot continues

 

object.

to spark after the

 

 

B. Poor flame rectification or contaminated

With fixed glass assembly in place, verify that flame is en-

pilot flame has been lit,

flame sensing rod.

gulfing flame sensing rod on left side of pilot hood. Flame

flame rectification has

 

sensing rod should glow shortly after ignition. Verify cor-

not occurred.)

 

 

rect pilot orifice is installed and gas inlet is set to pressure

 

 

 

 

specifications. Clean flame sensing rod with emery cloth to

 

 

remove any contaminants that may have accumulated on

 

 

flame sensing rod.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

 

 

pliance. Verify that wire harness is firmly connected to the

 

 

module.

 

 

 

 

D. Damaged pilot assembly or contami-

Verify that ceramic insulator around the flame sensing rod

 

nated flame sensing rod.

is not cracked, damaged, or loose. Verify connection from

 

 

flame sensing rod to white sensor wire. Clean flame sensing

 

 

rod with emery cloth to remove any contaminants that may

 

 

have accumulated on flame sensing rod. Verify continuity

 

 

with a multimeter with ohms set at lowest range. Replace

 

 

pilot if any damage is detected.

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position.

 

 

Remove ignitor wire “I” from module. Place ON/OFF rocker

 

 

switch or wall switch in ON position. If there is no spark at “I”

 

 

terminal module must be replaced. If there is a spark at “I”

 

 

terminal, module is fine.

 

 

 

40

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI2058-900 Rev. N • 11/08

Image 40
Contents Models 8000TV-OAK 8000TV-OAK-IPI 8000TVLP-OAKIPI What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Fan Kit optional Clear SpaceOutside Air optional Before Lighting FireplaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesCombustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesVent Guidelines Vent Information and DiagramsVent System Configuration Vent Clearances and Framing Pipe Clearances to CombustiblesWall and Ceiling Penetration Framing Vertical Penetration FramingInstalling Outside Air Kit Damper Assem- bly Appliance PreparationGas and Electrical Connections Securing and Leveling the ApplianceCompleting Grate Set-up Checking Pilot PlateInstalling Vent Pipe Assembly of Vent SectionsInstall Attic Insulation Shield Attaching Vent to FireboxGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Log Assembly LOGS-8OAK Install the Log AssemblyPage Fixed Glass Assembly Install the MeshInstall Trim and/or Surround Install HoodSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLog Set Assembly Service PartsService Parts List 8000TV-OAK, 8000TV-OAK-IPI At Depot8000TV-OAK-IPI Stocked8000TV-OAK Contact Information

8000TV-OAK, 8000TVLP-OAKIPI, 8000TV-OAK-IPI specifications

Hearth and Home Technologies has carved a notable niche in the world of home heating solutions, and their 8000TV-OAK-IPI, 8000TVLP-OAKIPI, and 8000TV-OAK models exemplify innovation, efficiency, and aesthetic appeal. Each model boasts unique features, yet they share a commitment to enhancing ambiance while ensuring effective warmth.

The 8000TV-OAK-IPI is designed with versatility in mind. It operates using an innovative IntelliFire® ignition system, which allows for easy startup and reliable performance. The model is compatible with natural gas and propane, giving homeowners the flexibility to choose based on their preferences. One of its key features includes the stunning oak finish, which complements a variety of interior designs, transforming any room into a cozy retreat. Its heat output is efficient, reaching up to 42,000 BTUs, which makes it perfect for larger spaces, ensuring consistent warmth throughout the area.

Similarly, the 8000TVLP-OAKIPI is tailored for those who prefer a liquid propane fuel source. It shares compatibility with advanced technology, featuring the IntelliFire® system that improves energy efficiency while minimizing the environmental impact. The design mirrors the oak aesthetics of its counterpart but adds functionality with customizable flame settings that allow homeowners to adjust the ambiance to their liking. This model also highlights a large viewing area, enabling a clear view of the vibrant flames while maximizing heat output.

The 8000TV-OAK model, while maintaining the traditional oak finish, sets itself apart with optional accessories such as decorative glass media, enabling personalization that caters to individual tastes. This model also benefits from advanced safety features, including an automatic shut-off system to ensure peace of mind during operation. The combination of practicality and style makes this option a popular choice.

All three models are equipped with exceptional insulation, resulting in lower energy costs. Their design encourages ease of maintenance; ash pans and glass cleanings have been simplified, ensuring that the upkeep of your hearth remains minimal. The integration of modern heating technology in these models illustrates Hearth and Home Technologies' dedication to combining craftsmanship with cutting-edge performance.

In conclusion, Hearth and Home Technologies' 8000TV-OAK-IPI, 8000TVLP-OAKIPI, and 8000TV-OAK models are perfect examples of how traditional aesthetics and modern technology can coalesce to create high-quality heating solutions. Designed with efficiency, safety, and ambiance in mind, these fireplaces are a worthy investment for anyone looking to enhance their living space with both warmth and style.