B. Intellifire Ignition System

Symptom

Possible Cause

Corrective Action

 

 

 

1. Pilot won’t light.

A. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are

The ignitor/module

 

connected to correct terminals on module and pilot assembly.

makes noise, but no

 

 

B. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from mod-

spark.

 

shorts in the wiring.

ule to pilot assembly. Verify connections underneath pilot assembly

 

 

are tight; also verify connections are not grounding out to metal

 

 

chassis, pilot burner, pilot enclosure, mesh screen if present, or any

 

 

other metal object.

 

 

 

 

C. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 in. or 1/8 in. (3 mm).

 

 

 

 

D. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place a grounded wire about 3/16 in. (5

 

 

mm) away from “I” terminal on module. Place ON/OFF rocker switch

 

 

or wall switch in ON position. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode. Replace pilot if necessary.

 

 

 

2. Pilot won’t light,

A. No power or transformer installed

Verify that transformer is installed and plugged into module. Check

there is no noise or

incorrectly.

voltage of transformer under load at spade connection on module

spark.

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

B. A shorted or loose connection in

Remove and reinstall the wiring harness that plugs into module.

 

wiring configuration or wiring har-

Verify there is a tight fit. Verify pilot assembly wiring to module. Re-

 

ness.

move and verify continuity of each wire in wiring harness. Replace

 

 

any damaged components.

 

 

 

 

C. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

D. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

 

 

switch in ON position. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

3. Pilot sparks, but

A. Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet

Pilot will not light.

 

pressure reading is within acceptable limits, inlet pressure must not

 

 

exceed 14 in. W.C.

 

 

 

 

B. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 in. or 1/8 in. (3 mm).

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

 

 

D. Module voltage output / Valve/Pilot

Verify battery voltage is at least 2.7 volts. Replace batteries if volt-

 

solenoid ohms readings.

age is below 2.7.

 

 

 

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI2058-900 Rev. N • 11/08

39

Image 39
Contents What to do if you smell gas Models 8000TV-OAK 8000TV-OAK-IPI 8000TVLP-OAKIPIHomeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Before Lighting Fireplace Fan Kit optionalClear Space Outside Air optionalFinal inspection by Lighting Instructions IPILighting Instructions Standing Pilot For Your Safety Read Before Lighting Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseMantel and Wall Projections Combustible MantelsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsVent Information and Diagrams Vent GuidelinesVent System Configuration Vertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingSecuring and Leveling the Appliance Installing Outside Air Kit Damper Assem- blyAppliance Preparation Gas and Electrical ConnectionsChecking Pilot Plate Completing Grate Set-upAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Intellifire Ignition System WiringIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Install the Log Assembly Log Assembly LOGS-8OAKPage Install Hood Fixed Glass AssemblyInstall the Mesh Install Trim and/or SurroundTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramService Parts Log Set AssemblyAt Depot Service Parts List 8000TV-OAK, 8000TV-OAK-IPIStocked 8000TV-OAK-IPI8000TV-OAK Contact Information

8000TV-OAK, 8000TVLP-OAKIPI, 8000TV-OAK-IPI specifications

Hearth and Home Technologies has carved a notable niche in the world of home heating solutions, and their 8000TV-OAK-IPI, 8000TVLP-OAKIPI, and 8000TV-OAK models exemplify innovation, efficiency, and aesthetic appeal. Each model boasts unique features, yet they share a commitment to enhancing ambiance while ensuring effective warmth.

The 8000TV-OAK-IPI is designed with versatility in mind. It operates using an innovative IntelliFire® ignition system, which allows for easy startup and reliable performance. The model is compatible with natural gas and propane, giving homeowners the flexibility to choose based on their preferences. One of its key features includes the stunning oak finish, which complements a variety of interior designs, transforming any room into a cozy retreat. Its heat output is efficient, reaching up to 42,000 BTUs, which makes it perfect for larger spaces, ensuring consistent warmth throughout the area.

Similarly, the 8000TVLP-OAKIPI is tailored for those who prefer a liquid propane fuel source. It shares compatibility with advanced technology, featuring the IntelliFire® system that improves energy efficiency while minimizing the environmental impact. The design mirrors the oak aesthetics of its counterpart but adds functionality with customizable flame settings that allow homeowners to adjust the ambiance to their liking. This model also highlights a large viewing area, enabling a clear view of the vibrant flames while maximizing heat output.

The 8000TV-OAK model, while maintaining the traditional oak finish, sets itself apart with optional accessories such as decorative glass media, enabling personalization that caters to individual tastes. This model also benefits from advanced safety features, including an automatic shut-off system to ensure peace of mind during operation. The combination of practicality and style makes this option a popular choice.

All three models are equipped with exceptional insulation, resulting in lower energy costs. Their design encourages ease of maintenance; ash pans and glass cleanings have been simplified, ensuring that the upkeep of your hearth remains minimal. The integration of modern heating technology in these models illustrates Hearth and Home Technologies' dedication to combining craftsmanship with cutting-edge performance.

In conclusion, Hearth and Home Technologies' 8000TV-OAK-IPI, 8000TVLP-OAKIPI, and 8000TV-OAK models are perfect examples of how traditional aesthetics and modern technology can coalesce to create high-quality heating solutions. Designed with efficiency, safety, and ambiance in mind, these fireplaces are a worthy investment for anyone looking to enhance their living space with both warmth and style.