Hearth and Home Technologies 8000TV-OAK-IPI, 8000TVLP-OAKIPI owner manual Troubleshooting

Page 38

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. (Continued)

C. Back drafting may be tripping the spill switch.

Negative pressure, wind or flue blockage may be

 

 

causing spillage. Perform negative pressure diagnos-

 

 

tics and inspect venting.

 

 

 

 

D. Valve.

Turn the valve knob to the ON position. Place the ON/

 

 

OFF switch in the ON position. Take a reading with a

 

 

millivolt meter at the thermopile terminals. The millivolt

 

 

meter should read greater than 125mV. If the reading

 

 

is acceptable, and if the burner does not come on, re-

 

 

place the gas valve.

 

 

 

 

E. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stop-

 

 

page.

 

 

 

 

F. Wall switch or wires.

Check the wall switch and wires for proper connec-

 

 

tions. Place the jumper wires across the terminals at

 

 

the wall switch. If the burner comes on, replace the

 

 

wall switch. If the wall switch is OK, place the jumper

 

 

wires across the wall switch wires at the gas valve. If

 

 

the burner comes on, the wires are faulty or connec-

 

 

tions are bad.

 

 

 

4. Frequent pilot outage

A. Pilot flame may be too high or too low, or blow-

Clean thermocouple and adjust the pilot flame for

problem.

ing out (high pressure), causing pilot safety to

proper flame impingement. Follow lighting instructions

 

drop out.

carefully.

 

 

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish

 

 

B. Improper gas inlet pressure.

Natural gas should be 5-14 in. w.c. LP should be 10-

while in operation.

 

14 in. w.c. Verify pressure with manometer.

 

 

 

 

 

 

C. Inner vent pipe leaking exhaust gases back

Check venting system for damage. Replace/repair im-

 

into the system.

properly assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace

 

 

fixed glass panel assembly.

 

 

 

 

E. Thermopile or thermocouple.

Replace pilot if necessary.

 

 

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris

 

 

or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the flame does not exces-

 

 

sively impinge on it. Refer to log instructions.

 

 

 

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set

 

 

point is correct for appliance/gas type. If unit has ad-

 

 

justable shutter, it may be necessary to increase shut-

 

 

ter opening.

 

 

 

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MA-

 

 

TERIAL SHOULD BE PLACED IN THIS OPENING.

 

 

 

7. Flame burns blue

A. Insufficient oxygen being supplied.

Ensure that the vent cap is installed properly and free

and lifts off burner.

 

of debris. Ensure that the vent system joints are tight

 

 

and have no leaks.

 

 

Ensure that no debris has been placed at the base of,

 

 

or in the area of the air holes in the center of the base

 

 

pan beneath the burner.

 

 

Ensure that the glass is tightened properly on the unit,

 

 

particularly on top corners.

 

 

 

38

Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI2058-900 Rev. N • 11/08

Image 38
Contents Models 8000TV-OAK 8000TV-OAK-IPI 8000TVLP-OAKIPI What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Outside Air optional Fan Kit optionalClear Space Before Lighting FireplaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions After Fireplace is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsEither cobrahead or SIT Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesCombustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Termination Locations Vent Termination Minimum ClearancesVent System Configuration Vent Information and DiagramsVent Guidelines Wall and Ceiling Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Vertical Penetration FramingGas and Electrical Connections Installing Outside Air Kit Damper Assem- blyAppliance Preparation Securing and Leveling the ApplianceCompleting Grate Set-up Checking Pilot PlateInstall Attic Insulation Shield Installing Vent PipeAssembly of Vent Sections Attaching Vent to FireboxGas Pressure Gas InformationFuel Conversion Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Log Assembly LOGS-8OAK Install the Log AssemblyPage Install Trim and/or Surround Fixed Glass AssemblyInstall the Mesh Install HoodStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLog Set Assembly Service PartsService Parts List 8000TV-OAK, 8000TV-OAK-IPI At Depot8000TV-OAK-IPI Stocked8000TV-OAK Contact Information

8000TV-OAK, 8000TVLP-OAKIPI, 8000TV-OAK-IPI specifications

Hearth and Home Technologies has carved a notable niche in the world of home heating solutions, and their 8000TV-OAK-IPI, 8000TVLP-OAKIPI, and 8000TV-OAK models exemplify innovation, efficiency, and aesthetic appeal. Each model boasts unique features, yet they share a commitment to enhancing ambiance while ensuring effective warmth.

The 8000TV-OAK-IPI is designed with versatility in mind. It operates using an innovative IntelliFire® ignition system, which allows for easy startup and reliable performance. The model is compatible with natural gas and propane, giving homeowners the flexibility to choose based on their preferences. One of its key features includes the stunning oak finish, which complements a variety of interior designs, transforming any room into a cozy retreat. Its heat output is efficient, reaching up to 42,000 BTUs, which makes it perfect for larger spaces, ensuring consistent warmth throughout the area.

Similarly, the 8000TVLP-OAKIPI is tailored for those who prefer a liquid propane fuel source. It shares compatibility with advanced technology, featuring the IntelliFire® system that improves energy efficiency while minimizing the environmental impact. The design mirrors the oak aesthetics of its counterpart but adds functionality with customizable flame settings that allow homeowners to adjust the ambiance to their liking. This model also highlights a large viewing area, enabling a clear view of the vibrant flames while maximizing heat output.

The 8000TV-OAK model, while maintaining the traditional oak finish, sets itself apart with optional accessories such as decorative glass media, enabling personalization that caters to individual tastes. This model also benefits from advanced safety features, including an automatic shut-off system to ensure peace of mind during operation. The combination of practicality and style makes this option a popular choice.

All three models are equipped with exceptional insulation, resulting in lower energy costs. Their design encourages ease of maintenance; ash pans and glass cleanings have been simplified, ensuring that the upkeep of your hearth remains minimal. The integration of modern heating technology in these models illustrates Hearth and Home Technologies' dedication to combining craftsmanship with cutting-edge performance.

In conclusion, Hearth and Home Technologies' 8000TV-OAK-IPI, 8000TVLP-OAKIPI, and 8000TV-OAK models are perfect examples of how traditional aesthetics and modern technology can coalesce to create high-quality heating solutions. Designed with efficiency, safety, and ambiance in mind, these fireplaces are a worthy investment for anyone looking to enhance their living space with both warmth and style.