Hearth and Home Technologies SL-750TRS-E, SL-550TRS-E Getting Started, Typical Appliance System

Page 18

4

Getting Started

Installer Guide

 

 

 

A. Typical Appliance System

NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual

Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally.

NON-COMBUSTIBLE ROOF FLASHING

MAINTAINS MINIMUM CLEARANCE

AROUND PIPE (SECTION 10.G)

VENT PIPE (SECTIONS 7 and 8)

CEILING FIRESTOP ON FLOOR OF ATTIC (SECTION 8.C)

FRAMING/HEADER (SECTION 5.B)

VERTICAL TERMINATION CAP (SECTION 10.J)

STORM COLLAR (SECTION 10.H)

VENT PIPE PENETRATES ROOF PREFERABLY WITHOUT AFFECTING ROOF RAFTERS (SECTION 8.C)

ATTIC INSULATION SHIELD (NOT SHOWN) MUST BE USED HERE TO KEEP INSULATION AWAY FROM VENT PIPE IF ATTIC IS INSULATED (SECTION 8.D)

HORIZONTAL

TERMINATION CAP (SECTION 10.M)

GAS LINE (SECTION 11)

FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C)

OPTIONAL

WALL SWITCH

MANTEL AND MANTEL LEG (SECTION 5.D)

SURROUND

HEARTH EXTENSION

Figure 4.1 Typical System

18

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI2120-901 Rev. G • 11/08

Image 18
Contents What to do if you smell gas HOT SurfacesHot glass will cause burns Congratulations Homeowner Reference InformationXxxxxxxx Table of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Appliance Certification High Altitude InstallationsListing and Code Approvals Tempered Glass SpecificationsElectrical Codes Non-Combustible Materials SpecificationCombustible Materials Specification C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions Issue SolutionsAfter Fireplace is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsEither cobrahead or SIT Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Any such action may cause a fire hazardFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections TOP ViewTermination Locations Vent Termination Minimum Clearances= Area Where Terminal is not Permitted = Vent Terminal = AIR Supply InletVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsUse of Flex Vent In. ClearanceMinimum H1 Maximum SL-350TRS-IPITop Vent Horizontal Termination Two Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 Maximum H1 + H2 Maximum V1 + V2 MinimumTop Vent Vertical Termination No Elbow = 60 ft. Max .3 m Exhaust restrictor InstructionsTop Vent Vertical Termination Two 90º Elbows Minimum Maximum + V 2 MinimumTop Vent Vertical Termination Three 90º Elbows ALL ModelsH1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Four 90º Elbows V1 Min H1 Max V2 Min H2 Max V3 MinH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination Three Elbows Rear Vent Vertical Termination One ElbowH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum Rear Vent Vertical Termination Two Elbows H1+ H2 Maximum V1 MinimumH1 Maximum V1 Minimum H1 + H2 Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Non-Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance 13 Proper Positioning and Securing of an ApplianceAssemble Vent Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Gas Pressure Gas InformationFuel Conversion Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsIntellifire Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Electrical Service and Repair Standing Pilot Ignition Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalTo install the Splatter Guard FinishingSplatter Guard To Close the Lower Access Panel To Remove the Splatter Guard14 Wall Projection Acceptable on one side of opening Facing Material 16 Facing MaterialsDoors TemplateElevated Hearth Systems Appliance Setup Install Refractory StepStep Install the Log Assembly Model SL-350TRS-D,SL-350TRS-IPIPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Step Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D LOG NotchesNotch Shutter Settings Install Trim and/or SurroundAir Shutter Setting SL-550TRS-IPI and SL-750TRS-IPI onlyTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsVent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP Horizontal Termination CapCOOL-ADD RF6M RF12MBEK DVP-BEK2 DVP-TRAPFLDVP-TV DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPDVP-TB1 RF4-8 ElbowExtended Heat Shield Roof Flashing Ceiling FirestopSnorkel Black Support Box-Black Wall Thimble-BlackAdapter Log Set Assembly Service PartsService Parts List At DepotIPI Valve Assembly StockedSL-550TRS-E, SL-550TRS-IPI-E Description Comments Part Number Standing Pilot Conversion KitsIPI Conversion Kits SL-750TRS-E, SL-750TRS-IPI-E SL-750TRS-E, SL-750TRS-IPI-E Service Parts SL-550TRS-IPI-E, SL-750TRS-IPI-E SL-550TRS-E, SL-750TRS-E Contact Information

SL-550TRS-E, SL-750TRS-E specifications

Hearth and Home Technologies has established a strong reputation in the hearth industry, and their SL-750TRS-E and SL-550TRS-E models are outstanding examples of their commitment to innovation, quality, and performance. These elegant linear gas fireplaces are designed to elevate any living space while providing warmth and comfort.

At the core of both models are advanced heating technologies that utilize efficient gas burners. The SL-750TRS-E features a high BTU output, maximizing heat transfer while minimizing energy costs. The SL-550TRS-E, while slightly smaller, still delivers impressive heating capabilities, making it ideal for a range of room sizes.

Both fireplaces boast unique design elements that enhance aesthetics. Large viewing areas with clean lines create a contemporary look that complements various interior styles. The sleek glass front allows for an unobstructed view of the flames, creating a focal point that captivates and warms a room simultaneously.

The electronic ignition system is another highlight of these models. It offers convenience and reliability, ensuring that users can easily start their fireplace with the simple push of a button. Integrated safety features, such as a flame sensor and battery backup, ensure worry-free operation even during power outages.

Customization options abound with the SL-750TRS-E and SL-550TRS-E. Users can select from a variety of decorative media, including glass crystals or river rocks, to personalize the appearance of their fireplace. Additionally, an included remote control or optional smart home integration allows for effortless temperature adjustments from anywhere in the room.

Installation versatility is a significant advantage of these models. They can be direct vented through the wall or roof, offering flexibility to homeowners and installers alike. The compact design also allows for installation in both new constructions and retrofitting into existing spaces.

In summary, Hearth and Home Technologies' SL-750TRS-E and SL-550TRS-E gas fireplaces combine efficiency with style. Featuring advanced heating technology, customizable aesthetics, and easy-to-use controls, these models are perfect for homeowners looking to enhance their living spaces with a blend of modern design and comfort. Whether for a cozy living room or a sophisticated lounge, these fireplaces exemplify quality craftsmanship and innovation in the hearth industry.