Hearth and Home Technologies SL-550TRS-E, SL-750TRS-E owner manual Facing Materials

Page 59

B. Facing Material

Metal front faces may be covered with non-combustible materials only.

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

Seal joints between the finished wall and appliance top and sides using a 300 °F minimum sealant. Refer to Figure 13.16.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

FACING MATERIAL UP TO 1/2 IN. THICK

MAY BE COMBUSTIBLE - TOP AND SIDES

NON-COMBUSTIBLE

0

IN.

BOARD (INCLUDED)

 

 

1 IN.

 

 

1 IN.

1 IN.

 

0 IN.

0 IN.

HIGH TEMPERATURE (300º F / 149º C MIN.)

TOP & SIDE SEAL JOINT

Figure 13.16 Facing Materials

Note: There are 3 metal tabs holding the non-combustible board in place for shipping. These tabs are to be cut off or bent back before finishing around the appliance front.

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI2120-901 Rev. G • 11/08

59

Image 59
Contents Hot glass will cause burns What to do if you smell gasHOT Surfaces Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Tempered Glass Specifications High Altitude InstallationsListing and Code Approvals Appliance CertificationC22.1 Non-Combustible Materials SpecificationCombustible Materials Specification Electrical CodesRequirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASLighting Instructions Standing Pilot For Your Safety Read Before Lighting Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsIssue Solutions Remote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingEither cobrahead or SIT Typical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseTOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination Locations= Vent Terminal = AIR Supply Inlet = Area Where Terminal is not PermittedUse of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyIn. Clearance Use of Flex VentSL-350TRS-IPI Minimum H1 MaximumMinimum Maximum Top Vent Horizontal Termination Two ElbowsV1 Minimum H1 Maximum H1 + H2 Maximum V1 + V2 Minimum Top Vent Horizontal Termination Three ElbowsExhaust restrictor Instructions Top Vent Vertical Termination No Elbow = 60 ft. Max .3 mMinimum Maximum + V 2 Minimum Top Vent Vertical Termination Two 90º ElbowsH1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Three 90º ElbowsALL Models V1 Min H1 Max V2 Min H2 Max V3 Min Top Vent Vertical Termination Four 90º ElbowsH1 Maximum V1 Minimum H1 + H2 Maximum H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum Rear Vent Horizontal Termination Three ElbowsRear Vent Vertical Termination One Elbow H1 Maximum V1 Minimum H1 + H2 Rear Vent Vertical Termination Two ElbowsH1+ H2 Maximum V1 Minimum Non-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationCut the metal retaining band and fold the sides out Rear Vent13 Proper Positioning and Securing of an Appliance Securing and Leveling the ApplianceAssemble Pipe Sections Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Refer to of this manual Install Horizontal Termination Cap DVP and SLP PipeAnsi Z223.1 and CAN/CGA-B149 installation codes Gas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsIntellifire Ignition System Wiring Standing Pilot Ignition System WiringIntellifire Ignition Wiring Diagram with Remote Receiver Standing Pilot Ignition Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationSplatter Guard To install the Splatter GuardFinishing To Remove the Splatter Guard To Close the Lower Access Panel14 Wall Projection Acceptable on one side of opening 16 Facing Materials Facing MaterialTemplate DoorsElevated Hearth Systems Appliance Setup Step Install RefractoryStep Model SL-350TRS-D,SL-350TRS-IPI Install the Log AssemblyPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Step LOG Notches Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- DNotch SL-550TRS-IPI and SL-750TRS-IPI only Install Trim and/or SurroundAir Shutter Setting Shutter SettingsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramP 4 5 4 5 E lb o w Vent Components DiagramsHorizontal Termination Cap DVP-TRAPDVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDDVP-TV DVP-TB1 DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAPSLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP Roof Flashing Ceiling Firestop ElbowExtended Heat Shield RF4-8Adapter Snorkel Black Support Box-BlackWall Thimble-Black Service Parts Log Set AssemblyAt Depot Service Parts ListStocked IPI Valve AssemblySL-550TRS-E, SL-550TRS-IPI-E IPI Conversion Kits Description Comments Part NumberStanding Pilot Conversion Kits SL-750TRS-E, SL-750TRS-IPI-E SL-750TRS-E, SL-750TRS-IPI-E Service Parts SL-550TRS-IPI-E, SL-750TRS-IPI-E SL-550TRS-E, SL-750TRS-E Contact Information

SL-550TRS-E, SL-750TRS-E specifications

Hearth and Home Technologies has established a strong reputation in the hearth industry, and their SL-750TRS-E and SL-550TRS-E models are outstanding examples of their commitment to innovation, quality, and performance. These elegant linear gas fireplaces are designed to elevate any living space while providing warmth and comfort.

At the core of both models are advanced heating technologies that utilize efficient gas burners. The SL-750TRS-E features a high BTU output, maximizing heat transfer while minimizing energy costs. The SL-550TRS-E, while slightly smaller, still delivers impressive heating capabilities, making it ideal for a range of room sizes.

Both fireplaces boast unique design elements that enhance aesthetics. Large viewing areas with clean lines create a contemporary look that complements various interior styles. The sleek glass front allows for an unobstructed view of the flames, creating a focal point that captivates and warms a room simultaneously.

The electronic ignition system is another highlight of these models. It offers convenience and reliability, ensuring that users can easily start their fireplace with the simple push of a button. Integrated safety features, such as a flame sensor and battery backup, ensure worry-free operation even during power outages.

Customization options abound with the SL-750TRS-E and SL-550TRS-E. Users can select from a variety of decorative media, including glass crystals or river rocks, to personalize the appearance of their fireplace. Additionally, an included remote control or optional smart home integration allows for effortless temperature adjustments from anywhere in the room.

Installation versatility is a significant advantage of these models. They can be direct vented through the wall or roof, offering flexibility to homeowners and installers alike. The compact design also allows for installation in both new constructions and retrofitting into existing spaces.

In summary, Hearth and Home Technologies' SL-750TRS-E and SL-550TRS-E gas fireplaces combine efficiency with style. Featuring advanced heating technology, customizable aesthetics, and easy-to-use controls, these models are perfect for homeowners looking to enhance their living spaces with a blend of modern design and comfort. Whether for a cozy living room or a sophisticated lounge, these fireplaces exemplify quality craftsmanship and innovation in the hearth industry.