Hearth and Home Technologies SL-750TRS-E, SL-550TRS-E Electrical Information, Wiring Requirements

Page 52

12 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (Intellifire ignition).

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

Determine if the appliance uses an Intellifire ignition sys- tem or standing pilot ignition system:

Open the control access panel or remove the decorative front.

A red or black ignitor button (as shown in Figure 12.1) indicates this appliance is standing pilot ignition.

 

RED OR

 

BLACK

 

BUTTON

Figure 12.1

Ignitor Button

B. Intellifire Ignition System Wiring

Wire the appliance junction box to 110 VAC for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figures 12.2 and 12.3, Intellifire Pilot Ignition (IPI) Wiring Diagram.

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

Plug the 3-volt AC transformer into the appliance junction box to supply power to the unit OR install two D cell batteries (not included) into the battery pack before use.

NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur.

C. Standing Pilot Ignition System Wiring

The standing pilot ignition system wiring does not require a 110 VAC supply to operate. See Figure 12.4.

A 110 VAC junction box MUST be installed for use with a fan or remote control. See Figure 12.5 for junction box wiring. Keep wire lengths short as possible.

NOTICE: DO NOT wire 110 VAC to the millivolt valve! This will damage the valve.

If using a thermostat use one compatible with a millivolt gas valve system:

-Install the thermostat in the location as indicated in the thermostat instructions to ensure proper operation of appliance.

-Use low resistance thermostat wire for wiring from ignition system to the wall switch and thermostat.

-Keep wire lengths short as possible.

D. Optional Accessories Requirements

This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.

52

Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI2120-901 Rev. G • 11/08

Image 52
Contents HOT Surfaces What to do if you smell gasHot glass will cause burns Homeowner Reference Information CongratulationsXxxxxxxx Table of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty High Altitude Installations Listing and Code ApprovalsAppliance Certification Tempered Glass SpecificationsNon-Combustible Materials Specification Combustible Materials SpecificationElectrical Codes C22.1Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Final inspection byWhat to do if YOU Smell GAS GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections TOP ViewTermination Locations Vent Termination Minimum Clearances= Area Where Terminal is not Permitted = Vent Terminal = AIR Supply InletVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsUse of Flex Vent In. ClearanceMinimum H1 Maximum SL-350TRS-IPITop Vent Horizontal Termination Two Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows V1 Minimum H1 Maximum H1 + H2 Maximum V1 + V2 MinimumTop Vent Vertical Termination No Elbow = 60 ft. Max .3 m Exhaust restrictor InstructionsTop Vent Vertical Termination Two 90º Elbows Minimum Maximum + V 2 MinimumALL Models Top Vent Vertical Termination Three 90º ElbowsH1+ H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Four 90º Elbows V1 Min H1 Max V2 Min H2 Max V3 MinH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Vertical Termination One Elbow Rear Vent Horizontal Termination Three ElbowsH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Maximum H1+ H2 Maximum V1 Minimum Rear Vent Vertical Termination Two ElbowsH1 Maximum V1 Minimum H1 + H2 Vent Clearances and Framing Pipe Clearances to Combustibles Wall Penetration FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance 13 Proper Positioning and Securing of an ApplianceInstalling Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSInstall Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Ansi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination Cap DVP and SLP PipeRefer to of this manual Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Intellifire Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsIntellifire Ignition Wiring Diagram with Remote Receiver Electrical Service and Repair Standing Pilot Ignition Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing To install the Splatter GuardSplatter Guard To Close the Lower Access Panel To Remove the Splatter Guard14 Wall Projection Acceptable on one side of opening Facing Material 16 Facing MaterialsDoors TemplateElevated Hearth Systems Appliance Setup Step Install RefractoryStep Install the Log Assembly Model SL-350TRS-D,SL-350TRS-IPIPage Model SL-550TRS-IPI-E Log Set Assembly LOGS-SL550TRS-D Step Model SL-750TRS-IPI-E Log Set Assembly LOGS-SL750TRS- D LOG NotchesNotch Install Trim and/or Surround Air Shutter SettingShutter Settings SL-550TRS-IPI and SL-750TRS-IPI onlySymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsVent Components Diagrams P 4 5 4 5 E lb o wDVP-TRAP Horizontal Termination CapRF6M RF12M BEK DVP-BEK2COOL-ADD DVP-TRAPFLDVP-TV SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAPDVP-TB1 Elbow Extended Heat ShieldRF4-8 Roof Flashing Ceiling FirestopWall Thimble-Black Snorkel Black Support Box-BlackAdapter Log Set Assembly Service PartsService Parts List At DepotIPI Valve Assembly StockedSL-550TRS-E, SL-550TRS-IPI-E Standing Pilot Conversion Kits Description Comments Part NumberIPI Conversion Kits SL-750TRS-E, SL-750TRS-IPI-E SL-750TRS-E, SL-750TRS-IPI-E Service Parts SL-550TRS-IPI-E, SL-750TRS-IPI-E SL-550TRS-E, SL-750TRS-E Contact Information

SL-550TRS-E, SL-750TRS-E specifications

Hearth and Home Technologies has established a strong reputation in the hearth industry, and their SL-750TRS-E and SL-550TRS-E models are outstanding examples of their commitment to innovation, quality, and performance. These elegant linear gas fireplaces are designed to elevate any living space while providing warmth and comfort.

At the core of both models are advanced heating technologies that utilize efficient gas burners. The SL-750TRS-E features a high BTU output, maximizing heat transfer while minimizing energy costs. The SL-550TRS-E, while slightly smaller, still delivers impressive heating capabilities, making it ideal for a range of room sizes.

Both fireplaces boast unique design elements that enhance aesthetics. Large viewing areas with clean lines create a contemporary look that complements various interior styles. The sleek glass front allows for an unobstructed view of the flames, creating a focal point that captivates and warms a room simultaneously.

The electronic ignition system is another highlight of these models. It offers convenience and reliability, ensuring that users can easily start their fireplace with the simple push of a button. Integrated safety features, such as a flame sensor and battery backup, ensure worry-free operation even during power outages.

Customization options abound with the SL-750TRS-E and SL-550TRS-E. Users can select from a variety of decorative media, including glass crystals or river rocks, to personalize the appearance of their fireplace. Additionally, an included remote control or optional smart home integration allows for effortless temperature adjustments from anywhere in the room.

Installation versatility is a significant advantage of these models. They can be direct vented through the wall or roof, offering flexibility to homeowners and installers alike. The compact design also allows for installation in both new constructions and retrofitting into existing spaces.

In summary, Hearth and Home Technologies' SL-750TRS-E and SL-550TRS-E gas fireplaces combine efficiency with style. Featuring advanced heating technology, customizable aesthetics, and easy-to-use controls, these models are perfect for homeowners looking to enhance their living spaces with a blend of modern design and comfort. Whether for a cozy living room or a sophisticated lounge, these fireplaces exemplify quality craftsmanship and innovation in the hearth industry.