Hearth and Home Technologies 6000GBV-LP, 6000GBV-IPILP owner manual Negative Pressure

Page 18

E. Negative Pressure

WARNING! Asphyxiation Risk! Negative pressure can cause spillage of combustion fumes and soot. Fireplace needs to draft properly for safety.

Draft is the pressure difference needed to vent fireplaces successfully. Considerations for successful draft include:

Preventing negative pressure

Location of fireplace and chimney

Negative pressure results from the imbalance of air available for the fireplace to operate properly. Causes for this imbalance include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air to furnace or air conditioning

Imbalances of the HVAC air handling system

Upper level air leaks (recessed lighting, attic hatch opening, duct leaks)

To minimize the effects of negative air pressure, the fol- lowing must be considered:

Install the fresh air kit. Install the intake on the side of the house towards prevailing winds during the heating season.

Ensure adequate outdoor air is supplied for combustion appliances and exhaust equipment.

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace.

Avoid installing the fireplace near doors, walkways or small isolated spaces.

Recessed lighting should be of “sealed can” design; attic hatches weather stripped or sealed; and attic mounted ductwork and air handler joints and seams taped or sealed.

Basement installations should be avoided due to stack effect. Stack effect creates negative pressure in lower levels. Hearth & Home Technologies recommends the use of direct vent fireplaces in basements.

Location of the fireplace and chimney will affect perfor- mance. As shown in Figure 4.2, the chimney should:

Be installed through the warm space enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fire.

Penetrate the highest part of the roof. This minimizes the effects of wind turbulence.

Be located away from trees, adjacent structures, uneven roof lines and other obstructions.

Offsets can restrict draft so their use should be minimized. Consider the fireplace location relative to floor and ceiling and attic joists.

Recommended Recommended

Location Location

Marginal

Location

Location

Not

Recommended

Location NOT

Recommended

Windward

Leeward

Multi-level Roofs

Figure 4.2

18

Heat & Glo • 6000GBV, 6000GBV-IPI2104-900 Rev. H • 11/08

Image 18
Contents Models 6000GBV 6000GBV-IPI 6000GBV-LP 6000GBV-IPILP What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions After Fireplace is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsIPI Pilot Flame Patterns Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Combustible MantelsCombustible Mantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesVent System Configuration Vent Information and DiagramsVent Guidelines Model Pipe SizeWall and Ceiling Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Vertical Penetration FramingAppliance Preparation Installing Outside Air Kit Damper Assem- blyInstalling the Non-combustible Board Gas and Electrical ConnectionsSecuring and Leveling the Appliance Proper Positioning, Leveling And Securing Of AnInstall Attic Insulation Shield Installing Vent PipeAssembly of Vent Sections Attaching Vent to FireboxGas Pressure Gas InformationFuel Conversion Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Install the Log Assembly Log #1 SRV2103-10712 Front View Install Trim and/or Surround Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLog Set Assembly Service PartsStanding Pilot Service Parts List 6000GBVAt Depot IPI Ignition6000GBV-IPI Standing Pilot Ignition Contact Information

6000GBV-IPI, 6000GBV-IPILP, 6000GBV-LP specifications

Hearth and Home Technologies (HHT) offers a range of innovative gas fireplaces, including the models 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI. Each of these fireplaces is designed to meet the evolving needs of modern homeowners while ensuring optimal performance, safety, and energy efficiency.

The 6000GBV-LP is a versatile propane-fueled gas fireplace that provides an appealing aesthetic combined with functionality. This model features an impressive viewing area that allows for maximum visibility of the flames, creating a warm and inviting ambiance. With its advanced burner technology, the 6000GBV-LP offers a realistic flame pattern and a variety of flame heights, giving users the ability to customize their experience. This model is also equipped with a variable speed blower, which enhances heat distribution and ensures an evenly warmed space.

Similarly, the 6000GBV-IPILP model stands out for its unique indirect venting system. This feature allows for flexible installation, accommodating different home layouts and preferences. The indirect venting system enables efficient heat transfer and venting without sacrificing aesthetics. Homeowners can choose from a range of stylish faceplates and decorative options, ensuring that the fireplace complements any interior design.

On the other hand, the 6000GBV-IPI model employs an innovative intermittent pilot ignition system, which significantly improves energy efficiency. This technology allows the pilot flame to be turned off when the fireplace is not in use, reducing gas consumption and minimizing environmental impact. The 6000GBV-IPI is also equipped with a thermostat control option, providing users with added convenience in regulating heat levels according to their comfort.

All three models are equipped with HHT's Heat Management technology, which ensures that heat is distributed effectively while keeping the fireplace's exterior cool to the touch. This feature enhances safety, making these fireplaces suitable for homes with children or pets.

Overall, the Hearth and Home Technologies 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI are exemplary models that combine modern design with advanced technology. These gas fireplaces cater to diverse homeowner needs, offering flexibility, efficiency, and elegance, making them a perfect choice for anyone looking to add warmth and style to their living space.