Hearth and Home Technologies 6000GBV-IPI Vent Information and Diagrams, Vent Guidelines

Page 23

7 Vent Information and Diagrams

A. Vent Guidelines

WARNING! Fire Risk/Asphyxiation! This appliance requires the specified pipe for operation. Incorrect pipe may cause spill- age, condensation and overheating.

These models require the following size B-vent double wall, or single wall rigid or flex vent pipe.

Model

Pipe Size

6000GBV

6 inch

 

 

6000GBV-IPI

6 inch

Follow pipe manufacturer’s installation guidelines when installing the appliance.

WARNING! Fire Risk/Explosion/Asphyxiation! DO NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance.

Vent this appliance directly outside.

Use separate vent system for this appliance.

May impair safe operation of this appliance or other appli- ances connected to the flue.

B. Vent System Configuration

CAUTION! Risk of Fire! ALL vent configuration specifi- cations MUST be followed. This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.

Rise to Run Ratio = 2:1

Maximum Total Horizontal Run = 15 Feet Minimum Total Vertical Rise = 9 Feet Maximum Total Vertical Rise = 30 Feet Maximum Number of Elbows: Two 90º or Four 45º

 

MINIMUM CLEARANCES

 

ARE PER VENT

 

MANUFACTURER’S

 

SPECIFICATIONS

 

METAL

9 FEET

PLUMBER’S

STRAP

MINIMUM

 

VENT SUPPORTS ARE PER

VENT MANUFACTURER’S

SPECIFICATIONS

Figure 7.1

Note: Horizontal runs must have minimum rise in accordance with mechanical codes.

VENT SUPPORTS

 

ARE PER VENT

METAL

MANUFACTURER'S

SPECIFICATIONS.

PLUMBERS' STRAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM HORIZONTAL RUN IS 50%

OF VERTICAL. HORIZONTAL RUN

CANNOT BE MORE THAN 15 FT.

Figure 7.2

WARNING! Risk of Fire or Explosion! Insulation and oth- er combustibles must not infringe on clearances.

ALWAYS maintain specified clearances around venting and firestop systems.

Install firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

MINIMUM VERTICAL 9 FEET

45DEGREES ELBOW

90DEGREES ELBOW

Figure 7.3

MAXIMUM HORIZONTAL

15 FEET

OFFSETS EXCEEDING 45 DEGREES ADAPT HORIZONTAL LIMITATIONS

Note: Maximum horizontal distance is 50% vertical vent height.

Heat & Glo • 6000GBV, 6000GBV-IPI2104-900 Rev. H • 11/08

23

Image 23
Contents What to do if you smell gas Models 6000GBV 6000GBV-IPI 6000GBV-LP 6000GBV-IPILPHomeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalFinal inspection by Lighting Instructions IPILighting Instructions Standing Pilot For Your Safety Read Before Lighting Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Typical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Negative Pressure Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseCombustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Vent Termination Minimum Clearances Termination LocationsModel Pipe Size Vent Information and DiagramsVent Guidelines Vent System ConfigurationVertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingGas and Electrical Connections Installing Outside Air Kit Damper Assem- blyInstalling the Non-combustible Board Appliance PreparationProper Positioning, Leveling And Securing Of An Securing and Leveling the ApplianceAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Intellifire Ignition System WiringIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Log #1 SRV2103-107 Install the Log Assembly12 Front View Air Shutter Settings Install Trim and/or SurroundAir Shutter Setting Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramService Parts Log Set AssemblyIPI Ignition Service Parts List 6000GBVAt Depot Standing Pilot6000GBV-IPI Standing Pilot Ignition Contact Information

6000GBV-IPI, 6000GBV-IPILP, 6000GBV-LP specifications

Hearth and Home Technologies (HHT) offers a range of innovative gas fireplaces, including the models 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI. Each of these fireplaces is designed to meet the evolving needs of modern homeowners while ensuring optimal performance, safety, and energy efficiency.

The 6000GBV-LP is a versatile propane-fueled gas fireplace that provides an appealing aesthetic combined with functionality. This model features an impressive viewing area that allows for maximum visibility of the flames, creating a warm and inviting ambiance. With its advanced burner technology, the 6000GBV-LP offers a realistic flame pattern and a variety of flame heights, giving users the ability to customize their experience. This model is also equipped with a variable speed blower, which enhances heat distribution and ensures an evenly warmed space.

Similarly, the 6000GBV-IPILP model stands out for its unique indirect venting system. This feature allows for flexible installation, accommodating different home layouts and preferences. The indirect venting system enables efficient heat transfer and venting without sacrificing aesthetics. Homeowners can choose from a range of stylish faceplates and decorative options, ensuring that the fireplace complements any interior design.

On the other hand, the 6000GBV-IPI model employs an innovative intermittent pilot ignition system, which significantly improves energy efficiency. This technology allows the pilot flame to be turned off when the fireplace is not in use, reducing gas consumption and minimizing environmental impact. The 6000GBV-IPI is also equipped with a thermostat control option, providing users with added convenience in regulating heat levels according to their comfort.

All three models are equipped with HHT's Heat Management technology, which ensures that heat is distributed effectively while keeping the fireplace's exterior cool to the touch. This feature enhances safety, making these fireplaces suitable for homes with children or pets.

Overall, the Hearth and Home Technologies 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI are exemplary models that combine modern design with advanced technology. These gas fireplaces cater to diverse homeowner needs, offering flexibility, efficiency, and elegance, making them a perfect choice for anyone looking to add warmth and style to their living space.