Hearth and Home Technologies 6000GBV-IPILP, 6000GBV-LP owner manual Listing and Code Approvals

Page 7

1 Listing and Code Approvals

A. Appliance Certification

MODELS: 6000GBV, 6000GBV-IPI, 6000GBV-LP, 6000GBV-IPILP

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: B-Vent Gas Appliance

STANDARD: ANSI Z21.50-2002•CGA2.2

This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Altitudes”.

May be installed in a sleeping room when the provisions for combustion, ventilation and dilution air are met per the requirements of ANSI 223.1/NFPA 54 National Fuel Gas Code. In Canada, installation in a sleeping room requires installation with a thermostat certified for use with this prod- uct. Consult your local authorities having jurisdiction.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Tempered Glass Specifications

Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as defined by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectur- al Testing, Inc. Reports 02-31919.01and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.

C. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Size

U.S. (0-2000 ft.) or Canada (2000-4500 ft.)

Input BTUH

Input BTUH

(DMS)

 

 

 

 

6000GBV

US

27,000

18,000

#40

6000GBV-IPI

CAN

24,300

16,200

#41

 

 

 

 

 

6000GBV-LP

US

27,000

18,000

#53

 

 

 

 

6000GBV-IPILP

CAN

24,300

16,200

#54

 

 

 

 

 

 

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA

C22.1.

A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Heat & Glo • 6000GBV, 6000GBV-IPI2104-900 Rev. H • 11/08

7

Image 7
Contents What to do if you smell gas Models 6000GBV 6000GBV-IPI 6000GBV-LP 6000GBV-IPILPHomeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalFinal inspection by Lighting Instructions IPILighting Instructions Standing Pilot For Your Safety Read Before Lighting Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Negative Pressure Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseCombustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsModel Pipe Size Vent Information and DiagramsVent Guidelines Vent System ConfigurationVertical Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Wall and Ceiling Penetration FramingGas and Electrical Connections Installing Outside Air Kit Damper Assem- blyInstalling the Non-combustible Board Appliance PreparationProper Positioning, Leveling And Securing Of An Securing and Leveling the ApplianceAttaching Vent to Firebox Installing Vent PipeAssembly of Vent Sections Install Attic Insulation ShieldGas Connection Gas InformationFuel Conversion Gas PressureOptional Accessories Requirements Wiring RequirementsStanding Pilot Ignition System Wiring Intellifire Ignition System WiringIntellifire Pilot Ignition IPI Wiring Diagram Electrical Service and RepairWall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingAppliance Setup Log #1 SRV2103-107 Install the Log Assembly12 Front View Air Shutter Setting Install Trim and/or SurroundAir Shutter Settings Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramService Parts Log Set AssemblyIPI Ignition Service Parts List 6000GBVAt Depot Standing Pilot6000GBV-IPI Standing Pilot Ignition Contact Information

6000GBV-IPI, 6000GBV-IPILP, 6000GBV-LP specifications

Hearth and Home Technologies (HHT) offers a range of innovative gas fireplaces, including the models 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI. Each of these fireplaces is designed to meet the evolving needs of modern homeowners while ensuring optimal performance, safety, and energy efficiency.

The 6000GBV-LP is a versatile propane-fueled gas fireplace that provides an appealing aesthetic combined with functionality. This model features an impressive viewing area that allows for maximum visibility of the flames, creating a warm and inviting ambiance. With its advanced burner technology, the 6000GBV-LP offers a realistic flame pattern and a variety of flame heights, giving users the ability to customize their experience. This model is also equipped with a variable speed blower, which enhances heat distribution and ensures an evenly warmed space.

Similarly, the 6000GBV-IPILP model stands out for its unique indirect venting system. This feature allows for flexible installation, accommodating different home layouts and preferences. The indirect venting system enables efficient heat transfer and venting without sacrificing aesthetics. Homeowners can choose from a range of stylish faceplates and decorative options, ensuring that the fireplace complements any interior design.

On the other hand, the 6000GBV-IPI model employs an innovative intermittent pilot ignition system, which significantly improves energy efficiency. This technology allows the pilot flame to be turned off when the fireplace is not in use, reducing gas consumption and minimizing environmental impact. The 6000GBV-IPI is also equipped with a thermostat control option, providing users with added convenience in regulating heat levels according to their comfort.

All three models are equipped with HHT's Heat Management technology, which ensures that heat is distributed effectively while keeping the fireplace's exterior cool to the touch. This feature enhances safety, making these fireplaces suitable for homes with children or pets.

Overall, the Hearth and Home Technologies 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI are exemplary models that combine modern design with advanced technology. These gas fireplaces cater to diverse homeowner needs, offering flexibility, efficiency, and elegance, making them a perfect choice for anyone looking to add warmth and style to their living space.