Hearth and Home Technologies 6000GBV-IPI, 6000GBV-LP Constructing the Appliance Chase, Clearances

Page 20

B. Constructing the Appliance Chase

A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.

NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps.

Chases should be constructed in the manner of all out- side walls of the home to prevent cold air drafting prob- lems. The chase should not break the outside building envelope in any manner.

Walls, ceiling, base plate and cantilever floor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infiltration may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling fire- stops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with high temp caulk or stuffed with unfaced in- sulation. If the appliance is being installed on a cement slab, a layer of plywood may be placed underneath to prevent conducting cold up into the room.

C. Clearances

NOTICE: Install appliance on hard metal or wood surfaces extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other than wood.

WARNING! Risk of Fire! Maintain specified air space clearances to appliance and vent pipe:

Insulation and other materials must be secured to prevent accidental contact.

The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney.

Failure to maintain airspace may cause overheating and a fire.

A

E

FJ

B

C

D

H

G

I

* MINIMUM FRAMING DIMENSIONS

 

A

B

C

D

E

F

G

H

I

J

 

Rough

Rough

Rough

Rough

Clearance

Combustible

Combustible

Behind

Sides of

Front of

 

Opening

Opening

Opening

Opening

 

to Ceiling

Floor

Flooring

Appliance

Appliance

Appliance

 

(Vent Pipe)

(Height)

(Depth)

(Width)

 

 

 

 

 

 

 

Inches

10

38-1/2

22

42

26-5/8

0

0

1/2

1/2

36

 

 

 

 

 

 

 

 

 

 

 

Millimeters

254

978

559

1067

676

0

0

13

13

915

 

 

 

 

 

 

 

 

 

 

 

* Adjust framing dimensions for interior sheathing (such as sheetrock)

Figure 5.2 Clearances to Combustibles

20

Heat & Glo • 6000GBV, 6000GBV-IPI2104-900 Rev. H • 11/08

Image 20
Contents Models 6000GBV 6000GBV-IPI 6000GBV-LP 6000GBV-IPILP What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsIPI Pilot Flame Patterns Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesCombustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Termination Locations Vent Termination Minimum ClearancesVent Information and Diagrams Vent GuidelinesVent System Configuration Model Pipe SizeVent Clearances and Framing Pipe Clearances to CombustiblesWall and Ceiling Penetration Framing Vertical Penetration FramingInstalling Outside Air Kit Damper Assem- bly Installing the Non-combustible BoardAppliance Preparation Gas and Electrical ConnectionsSecuring and Leveling the Appliance Proper Positioning, Leveling And Securing Of AnInstalling Vent Pipe Assembly of Vent SectionsInstall Attic Insulation Shield Attaching Vent to FireboxGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Install the Log Assembly Log #1 SRV2103-10712 Front View Air Shutter Settings Install Trim and/or SurroundAir Shutter Setting Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLog Set Assembly Service PartsService Parts List 6000GBV At DepotStanding Pilot IPI Ignition6000GBV-IPI Standing Pilot Ignition Contact Information

6000GBV-IPI, 6000GBV-IPILP, 6000GBV-LP specifications

Hearth and Home Technologies (HHT) offers a range of innovative gas fireplaces, including the models 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI. Each of these fireplaces is designed to meet the evolving needs of modern homeowners while ensuring optimal performance, safety, and energy efficiency.

The 6000GBV-LP is a versatile propane-fueled gas fireplace that provides an appealing aesthetic combined with functionality. This model features an impressive viewing area that allows for maximum visibility of the flames, creating a warm and inviting ambiance. With its advanced burner technology, the 6000GBV-LP offers a realistic flame pattern and a variety of flame heights, giving users the ability to customize their experience. This model is also equipped with a variable speed blower, which enhances heat distribution and ensures an evenly warmed space.

Similarly, the 6000GBV-IPILP model stands out for its unique indirect venting system. This feature allows for flexible installation, accommodating different home layouts and preferences. The indirect venting system enables efficient heat transfer and venting without sacrificing aesthetics. Homeowners can choose from a range of stylish faceplates and decorative options, ensuring that the fireplace complements any interior design.

On the other hand, the 6000GBV-IPI model employs an innovative intermittent pilot ignition system, which significantly improves energy efficiency. This technology allows the pilot flame to be turned off when the fireplace is not in use, reducing gas consumption and minimizing environmental impact. The 6000GBV-IPI is also equipped with a thermostat control option, providing users with added convenience in regulating heat levels according to their comfort.

All three models are equipped with HHT's Heat Management technology, which ensures that heat is distributed effectively while keeping the fireplace's exterior cool to the touch. This feature enhances safety, making these fireplaces suitable for homes with children or pets.

Overall, the Hearth and Home Technologies 6000GBV-LP, 6000GBV-IPILP, and 6000GBV-IPI are exemplary models that combine modern design with advanced technology. These gas fireplaces cater to diverse homeowner needs, offering flexibility, efficiency, and elegance, making them a perfect choice for anyone looking to add warmth and style to their living space.