Hearth and Home Technologies Bravo, Aztec owner manual Alcove Applications, Appliance

Page 10

M

N

P

R

Q

(See Note 2)

V

T

VS Electrical Service

D*

V

S

V

V

= VENT TERMINAL

X = AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

A

=

12 inches

clearances above grade, veranda,

K

=

3 ft. (U.S.A.)

...........

clearance to a mechanical

 

 

(See Note 1)

porch, deck or balcony

 

 

 

6 ft. (Canada)

 

 

 

 

 

 

 

 

 

 

 

 

 

(powered) air supply inlet

B

=

12 inches

clearances to window or door

 

 

 

 

 

 

 

 

L**

=

7 ft

 

clearance above paved

 

 

 

that may be opened, or to perma-

 

 

 

 

 

 

 

 

(See Note 1)

 

sidewalk or a paved driveway

 

 

 

nently closed window. (Glass)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

located on public property

D*

=

18 inches

vertical clearance to unventilated

 

 

 

 

 

 

 

 

M*** =

18 inches

 

clearance under veranda, porch,

 

 

 

soffit or to ventilated soffit located

 

 

 

 

 

 

 

 

deck, balcony or overhang

 

 

 

above the terminal

 

 

 

42 inches

 

vinyl

 

 

*30 inches

for vinyl clad soffits and below

 

 

 

 

 

 

S

=

6 inches

 

clearance from sides of elec-

 

 

 

electrical service

 

 

 

 

 

 

 

 

(See Note 5)

 

 

trical service

F

=

9 inches

clearance to outside corner

 

 

 

 

 

 

T

=

12 inches

 

clearance above electrical

G

=

6 inches

clearance to inside corner

 

 

 

 

 

(See Note 5)

 

 

service

H

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

meter/regulator assembly within 3

 

Alcove Applications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

feet (90cm) horizontally from the

 

N

 

=

6 inches

 

 

non-vinyl sidewalls

 

 

 

 

center-line of the regulator

 

 

 

 

12 inches

 

 

vinyl sidewalls

 

I

=

3 ft. (U.S.A.)

 

 

P

 

=

8 ft.

 

 

 

 

 

 

 

 

 

6 ft. (Canada)

clearance to gas service regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

 

RMAX

 

 

 

 

 

vent outlet

 

 

 

 

 

 

 

 

 

 

J

=

9 inches (U.S.A.)

 

 

 

1 cap

 

 

3 feet

 

2 x Q ACTUAL

 

 

 

 

12 inches (Canada) clearance to non-mechanical

 

 

2 caps

 

 

6 feet

 

1 x Q ACTUAL

 

 

 

 

 

air supply inlet to building or the

 

 

3 caps

 

 

9 feet

 

2/3 x Q ACTUAL

 

 

 

 

 

combustion air inlet to any other

 

 

4 caps

 

12 feet

 

1/2 x Q ACTUAL

 

 

 

 

 

appliance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)

NOTE 2: Termination in an alcove space (spaces open only on one side

and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

Figure 4.4 Minimum Clearances for Termination

NOTE 3: Local codes or regulations may require different clearances.

NOTE 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere with access to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permitted in

screened porches. You must follow side wall, overhang and ground

clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.

Hearth & Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

10

Hearth & Home Technologies • Bravo, Aztec • InD • 703-900 Rev. N • 8/06

Image 10
Contents Models Aztec Bravo Congratulations Homeowner Reference InformationTable of Contents Appliance Certification High Altitude Installations1Listing and Code Approvals Glass SpecificationsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationClearances Constructing the Appliance ChaseClearance to Combustibles Mantel Projections Vent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications ApplianceUse of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsMinimum Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows V1 + V2 Minimum H1 + H2 Maximum ÍTop Vent Vertical Termination No Elbow V1 = 46 ft. Max .0 m Flue OutletV1 Minimum H1 Maximum Top Vent Vertical Termination H1 + H2Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration Framing Non-Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Securing and Leveling the ApplianceAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Termination Cap 13 Minimum Height from Roof to Lowest Discharge OpeningAssembling and Installing Storm Collar 16 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Wall Switch RequiredIntellifire Pilot Ignition IPI Wiring Diagram Junction Box Installation Wall Switch Installation for Fan Optional11Finishing Facing MaterialOption a Flush Wall Finish Finishing StylesOption B Kiva-style Arch Option C Southwestern kiva-style Flush wall installation with Luxor Surround Option D Flush Wall Finish with Luxor SurroundAccessories Appliance SetupClean the Appliance Lava Rock and Ember PlacementLog Assembly LOGS-AZTEC Positioning the LogsGrooves For LOG #4 Grooves For LOG #7 Log Assembly LOGS-BRAVO Right Grate Tine LOG #6 Replacing Glass Assembly Glass AssemblyRemoving Glass Assembly Shutter SettingsOperating Instructions Before Lighting ApplianceIntellifire Ignition Turn off all electric power to the appliLighting Appliance AnceInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Inspect Mantenance Tasks Recommend addition of screen if one is not presentAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45 45 ElbowDVP-TRAPK2 DVP and SL Series Components RF6MLog Set Assembly Service Parts List14 12 16 Additional service part numbers may appear on the following AztecService Parts Log Set AssemblyBravo AZTEC, Bravo Intermittent Pilot IgnitionLimited Lifetime Warranty Bravo GAS Appliance ProductsHow to Obtain Service Limited Lifetime WarrantyYear Limited Warranty Conditions, Exclusions, & Limitations of LiabilityFor safe installation Operation Contact Information

Bravo, Aztec specifications

Hearth and Home Technologies, a leader in the fireplace and heating industry, offers a remarkable range of products designed to meet the diverse needs of homeowners. Among their distinguished offerings are the Aztec and Bravo series of gas fireplaces, known for their blend of aesthetic appeal, efficiency, and innovative technologies.

The Aztec series stands out with its sophisticated design and versatile installation options. Available in multiple sizes, the Aztec fireplaces are adaptable to different spaces, allowing homeowners to choose a model that complements their interior design. A notable feature of the Aztec series is its captivating flame presentation, which is enhanced by state-of-the-art flame control technology. This technology allows users to adjust the intensity of the flames, creating the perfect ambiance for any occasion.

In addition to its striking visuals, the Aztec series is engineered for energy efficiency. Utilizing a highly efficient gas burner, these fireplaces provide substantial heat output while minimizing energy consumption. The inclusion of advanced ceramic glass helps improve heat retention, allowing more warmth to stay within the room and reducing overall energy costs. Moreover, the integrated fan system ensures optimal airflow, enhancing heat distribution throughout the living space.

The Bravo series, on the other hand, introduces an equally impressive set of features that appeal to both style and functionality. Bravo fireplaces are designed with a contemporary aesthetic in mind, featuring sleek lines and modern finishes. They come equipped with customizable options, allowing homeowners to personalize their fireplace with various door styles and frame finishes.

One of the standout characteristics of the Bravo series is its powerful heating capabilities. These fireplaces are built with advanced burner technology that delivers impressive heat output, making them suitable for larger areas. Furthermore, the Bravo series incorporates a user-friendly control system, granting users the convenience of adjusting settings via a remote control or smartphone app, enhancing the overall experience.

Both the Aztec and Bravo series are constructed with high-quality materials, ensuring durability and long-lasting performance. Hearth and Home Technologies prioritize safety and ease of use, and both series include safety features such as automatic shut-off mechanisms and child safety locks.

In conclusion, Hearth and Home Technologies’ Aztec and Bravo series offer exceptional choices for homeowners seeking stylish and efficient gas fireplaces. Their combination of advanced technologies, aesthetic versatility, and user-friendly features make them noteworthy contenders in the market, elevating the experience of warmth and comfort in any home setting.