Hearth and Home Technologies Aztec, Bravo After Appliance is Lit, Frequently Asked Questions

Page 45

C. After Appliance is Lit

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

NOTE: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

Combustible materials may ignite.

D. Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation of the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance is al-

lowed to burn for 20 to 40 minutes.

 

 

 

 

When first operated, this appliance may release an odor for the first several hours. This is

Odor from appliance

caused by the curing of the paint and the burning off of any oils remaining from manufactur-

ing. Odor may also be released from finishing materials and adhesives used around the

 

 

appliance.

 

 

Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned

within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing

 

process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See

 

your dealer.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

Metallic noise

the sound produced by a furnace or heating duct. This noise does not affect the operation or

 

longevity of the appliance.

 

 

Is it normal to see the pilot flame burn

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when

continually?

ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

 

 

Hearth & Home Technologies, Inc. • Bravo, Aztec • InD • 703-900 Rev. N • 8/06

45

Image 45
Contents Models Aztec Bravo Homeowner Reference Information CongratulationsTable of Contents 1Listing and Code Approvals High Altitude InstallationsAppliance Certification Glass SpecificationsGetting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesConstructing the Appliance Chase ClearancesClearance to Combustibles Mantel Projections Termination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Appliance Alcove ApplicationsVent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsMinimum Maximum V1 Minimum H1 + H2 MaximumV1 + V2 Minimum H1 + H2 Maximum Í Top Vent Horizontal Termination Three ElbowsFlue Outlet Top Vent Vertical Termination No Elbow V1 = 46 ft. Max .0 mV1 Minimum H1 Maximum H1 + H2 Top Vent Vertical TerminationPipe Clearances to Combustibles Wall Penetration Framing Vent Clearances and FramingCombustible Wall Penetration Non-Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination 13 Minimum Height from Roof to Lowest Discharge Opening Installing Roof Flashing and Vertical Termination Cap16 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Wall Switch RequiredIntellifire Pilot Ignition IPI Wiring Diagram Wall Switch Installation for Fan Optional Junction Box InstallationFacing Material 11FinishingFinishing Styles Option a Flush Wall FinishOption B Kiva-style Arch Option C Southwestern kiva-style Option D Flush Wall Finish with Luxor Surround Flush wall installation with Luxor SurroundClean the Appliance Appliance SetupAccessories Lava Rock and Ember PlacementPositioning the Logs Log Assembly LOGS-AZTECGrooves For LOG #4 Grooves For LOG #7 Log Assembly LOGS-BRAVO Right Grate Tine LOG #6 Removing Glass Assembly Glass AssemblyReplacing Glass Assembly Shutter SettingsBefore Lighting Appliance Operating InstructionsLighting Appliance Turn off all electric power to the appliIntellifire Ignition AnceFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Recommend addition of screen if one is not present Inspect Mantenance TasksReference Materials Appliance Dimension DiagramDVP45 45 Elbow Vent Components DiagramsDVP-TRAPK2 RF6M DVP and SL Series ComponentsService Parts List Log Set Assembly14 12 16 Aztec Additional service part numbers may appear on the followingLog Set Assembly Service PartsBravo Intermittent Pilot Ignition AZTEC, BravoBravo GAS Appliance Products Limited Lifetime WarrantyYear Limited Warranty Limited Lifetime WarrantyHow to Obtain Service Conditions, Exclusions, & Limitations of LiabilityContact Information For safe installation Operation

Bravo, Aztec specifications

Hearth and Home Technologies, a leader in the fireplace and heating industry, offers a remarkable range of products designed to meet the diverse needs of homeowners. Among their distinguished offerings are the Aztec and Bravo series of gas fireplaces, known for their blend of aesthetic appeal, efficiency, and innovative technologies.

The Aztec series stands out with its sophisticated design and versatile installation options. Available in multiple sizes, the Aztec fireplaces are adaptable to different spaces, allowing homeowners to choose a model that complements their interior design. A notable feature of the Aztec series is its captivating flame presentation, which is enhanced by state-of-the-art flame control technology. This technology allows users to adjust the intensity of the flames, creating the perfect ambiance for any occasion.

In addition to its striking visuals, the Aztec series is engineered for energy efficiency. Utilizing a highly efficient gas burner, these fireplaces provide substantial heat output while minimizing energy consumption. The inclusion of advanced ceramic glass helps improve heat retention, allowing more warmth to stay within the room and reducing overall energy costs. Moreover, the integrated fan system ensures optimal airflow, enhancing heat distribution throughout the living space.

The Bravo series, on the other hand, introduces an equally impressive set of features that appeal to both style and functionality. Bravo fireplaces are designed with a contemporary aesthetic in mind, featuring sleek lines and modern finishes. They come equipped with customizable options, allowing homeowners to personalize their fireplace with various door styles and frame finishes.

One of the standout characteristics of the Bravo series is its powerful heating capabilities. These fireplaces are built with advanced burner technology that delivers impressive heat output, making them suitable for larger areas. Furthermore, the Bravo series incorporates a user-friendly control system, granting users the convenience of adjusting settings via a remote control or smartphone app, enhancing the overall experience.

Both the Aztec and Bravo series are constructed with high-quality materials, ensuring durability and long-lasting performance. Hearth and Home Technologies prioritize safety and ease of use, and both series include safety features such as automatic shut-off mechanisms and child safety locks.

In conclusion, Hearth and Home Technologies’ Aztec and Bravo series offer exceptional choices for homeowners seeking stylish and efficient gas fireplaces. Their combination of advanced technologies, aesthetic versatility, and user-friendly features make them noteworthy contenders in the market, elevating the experience of warmth and comfort in any home setting.