Operating Humidifier Controls
The operating controls of your Kenmore Quiet Comfort Whole House humidifier are located on the top center of the humidifier. The controls are found under the smoked cover, located between the air circulating fans. Lift the control cover by placing your finger in the round cutout and lifting. The cover will stay open. Now you can clearly see the control area. Familiarize yourself with the controls and reference the dia- gram of the control area for the correct naming used in this manual.
To Operate the Controls
Humidity Control:
Adjust the amount of humidity depending on your needs. The humidifier will turn on and off as required to maintain level of humidity selected. MEDIUM setting is rec- ommended, but there are times when low or high amount of humidity may be pre- ferred. For constant operation of humidi- tier, MAX allows for the maximum amount of humidity to be evaporated into the air continuously.
IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity Control setting should be lowered until condensation no longer forms.
Fan Control
Your Kenmore Quiet Comfort Whole
House humidifier allows a choice to be
made for single or dual fan control. The slide switch allows one or two fans to be
used. Slide the switch to the "1" position to operate one fan and the "2° position to operate both fans.
The benefits of two fans and two control
settings to the customer are summed up in the name, "QUIET COMFORT WHOLE HOUSE HUMIDIFIER". The "FAN" slide
switch, positioned in the #1 position will operate the humidifier with one fan only in any speed position and provides reduced output at a lower noise level. The "FAN" slide switch positioned in the #2 setting will operate the humidifier with both fans and provides greater output than the sin- gle fan settings. Maximum output is pro- vided by the humidifier in the #2 position with the speed control set at high. This allows an infinite number of fan/speed set- tings, to determine the noise level and out _ut level that best suits you.
QuietComfort13
HUMIDITYM_
Power Light
When the unit is turned on, the power light will come on. It will stay on until the unit is turned off or unplugged.
Fill 't:i lht
When the unit has a small amount of water left in it, the fill light will come on and the unit will automatically shut off.
MAX
OFF
SPEED
LOW
Speed Control
The unit is adjusted from "OFF" to high to low with a variable speed control.
The higher the air flow speed, the more water is evaporated and released into the air. Low speed is the quietest and is pro- vided for conditions that may not require as.l_jh an evaporation rate.
POWER
FANS
7