Sears 153.326362, 153.326363 owner manual Water Piping

Page 9

Before making the conversion to 5500 watts, check the (1) power supply . . . must be 240 volts, (2) wiring . . . 10 gauge AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers or fusing . . .capable of 30 amp loading. Also, the installation must conform with this manual, local codes and electric utility rules. Failure to comply can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation” section in this manual.

See Figure 7 (below) for mixing valve usage.

FIGURE 6.

NOTE: Whether or not the element conversion is made the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel.

Water Piping

FIGURE 7.

Figure 8 shows the attachment of the water piping to the water heater. The water heater is equipped with 3/4” water connections.

If a water heater is installed in a closed water supply system; such as one having a back-flow preventer, check valve, water meter with a check valve, etc... in the cold water supply; means must be provided to control thermal expansion. Contact the local utility or Sears Service Center on how to control this situation.

NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the water inlet connection. Do not solder the water supply lines directly to the cold water inlet. It will harm the dip tube and damage the tank.

9

Image 9
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser Electric Water HeaterSafe INSTALLATION, USE and Service General Safety Table of Contents Introduction Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsRemoving the Old Water Heater Installation InstructionsFacts to Consider About the Location Insulation BlanketsFacts to Consider About Convertible Lower Element Water Piping Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Converting the Lower Element Page Wiring Page Wiring Diagrams Temperature Regulation Service and AdjustmentTemperature Settings Upper and Lower Thermostat Adjustments ThermostatsTemperature-Pressure Relief Valve Operation Anode Rod InspectionDraining Element Cleaning/Replacement Thermostat Removal/ReplacementPage Page Service Drain Valve Washer ReplacementTroubleshooting Start Up ConditionsOperational Conditions AIR in HOT Water Faucets Water is TOO HOT Leakage Checkpoints Model Numbers Repair Parts ListBuss Bar Kit 9001591 153.326862 Gallon Short 153.326863 Page Page MY-HOME