TROUBLESHOOTING

Start Up Conditions

THERMAL EXPANSION

NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.

Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc...to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater's temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected.

It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank to relieve the pressure built by thermal expansion in the water system. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations.

Thermal Expansion Tank Specifications

 

Tank

Dimensions

Pipe

Model

Capacity

in Inches

Fitting

Number

In Gallons

Diameter

Length

On Tank

153.331020

2

8 (203 mm)

12-3/4 (323 mm)

3/4” Male

153.331050

5

11 (279 mm)

14-3/4 (375 mm)

3/4” Male

Expansion Tank Sizing Chart

 

Inlet*

Water Heater Capacity (Gallons)

 

Water

 

 

 

 

 

Expansion

Pressure

30

40

50

66

82

40psi

2

2

2

5

5

Tank

50psi

2

2

2

5

5

Capacity

60psi

2

2

5

5

5

Needed

70psi

2

2

5

5

5

 

80psi

2

5

5

5

5

*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.

FIGURE 43.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.

Operational Conditions

SMELLY WATER

In each glass-lined water heater there is installed one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell”. This odor is derived from hydrogen sulfide gas dissolved in the water. The smell is the result of four factors which must all be present for the odor to develop:

A.A concentration of sulfate in the supply water.

B.Little or no dissolved oxygen in the water.

C.A sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)

23

Image 23
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser Electric Water HeaterSafe INSTALLATION, USE and Service General Safety Table of Contents Introduction Product SpecificationsBasic Tools Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Materials NeededRemoving the Old Water Heater Installation InstructionsFacts to Consider About Convertible Lower Element Facts to Consider About the LocationInsulation Blankets Water Piping Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Converting the Lower Element Page Wiring Page Wiring Diagrams Thermostats Service and AdjustmentTemperature Regulation Temperature Settings Upper and Lower Thermostat AdjustmentsDraining Temperature-Pressure Relief Valve OperationAnode Rod Inspection Element Cleaning/Replacement Thermostat Removal/ReplacementPage Page Service Drain Valve Washer ReplacementOperational Conditions TroubleshootingStart Up Conditions AIR in HOT Water Faucets Water is TOO HOT Leakage Checkpoints Model Numbers Repair Parts ListBuss Bar Kit 9001591 153.326862 Gallon Short 153.326863 Page Page MY-HOME