Sears 153.326362, 153.326363 owner manual Introduction, Product Specifications

Page 5

INTRODUCTION

Thank You for purchasing a Sears water heater. Properly installed and maintained, it should give you years of trouble free service. It is strongly suggested that this new water heater be professionally installed, contact the local Sears Service Center or any Sears store. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

UL – Underwriters Laboratories Inc.

NEC – National Electrical Code

ANSI – American National Standards Institute

Read the “General Safety” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of this electric water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THIS ENTIRE MANUALBEFOREATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this manual; electric company rules; and Local Codes, or in the absence of Local Codes, with the current edition of the NEC - National Electrical Code, NFPA 70. This publication is available from your local government or public library or electric company or by writing Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do not understand any portion of the instructions, call Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires.

Examine the location to ensure the water heater complies with the “Facts to Consider About the Location” section.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from the California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00; State Plumbing Code and 248-CMR 5.00. In the Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gasfitter.

PRODUCT SPECIFICATIONS

 

 

 

 

DIMENSIONS

 

ELEMENT

 

MAXIMUM FUSE

 

 

TANK

 

RECOVERY RATE

WATTAGE

MINIMUM

OR CIRCUIT

MODEL

 

CAPACITY

IN INCHES (mm)

GALS.PER HOUR

@ 240 VOLTS

WIRE SIZE*

BREAKER

NUMBER

 

IN GALLONS

DIA.

HEIGHT

@900F Rise

UPPER

LOWER

(GAUGE)

SIZE (AMPS)

153.326362

 

30

18.0

(457)

46.5

(1181)

 

17.3

3800

3800

12

20

 

 

30

18.0 (457)

46.5 (1181)

 

 

 

 

 

 

153.326363

 

25.0

3800

5500

10

30

 

30

18.0

(457)

46.5

(1181)

 

153.326462

 

40

18.0

(457)

59.5

(1511)

 

17.3

3800

3800

12

20

 

 

40

18.0 (457)

59.5 (1511)

 

 

 

 

 

 

153.326463

 

25.0

3800

5500

10

30

 

40

18.0

(457)

59.5

(1511)

 

153.326562

 

 

 

 

 

 

 

17.3

3800

3800

12

20

55

20.5

(521)

60.25 (1530)

 

 

55

20.5 (521)

60.25 (1530)

 

 

 

 

 

 

153.326563

 

25.0

3800

5500

10

30

 

55

20.5

(521)

60.25 (1530)

 

153.326662

 

50

23.0

(584)

49.0

(1245)

 

17.3

3800

3800

12

20

 

 

50

23.0 (584)

49.0 (1245)

 

 

 

 

 

 

153.326663

 

25.0

3800

5500

10

30

 

50

23.0

(584)

49.0

(1245)

 

153.326762

 

40

20.5

(521)

44.0 (1118)

 

17.3

3800

3800

12

20

 

 

40

20.5 (521)

44.0 (1118)

 

 

 

 

 

 

153.326763

 

25.0

3800

5500

10

30

 

40

20.5

(521)

44.0 (1118)

 

153.326862

 

47

26.5

(673)

34.0

(864)

 

17.3

3800

3800

12

20

 

 

50

26.5 (673)

34.0 (864)

 

 

 

 

 

 

153.326863

 

25.0

3800

5500

10

30

 

47

26.5

(673)

34.0

(864)

 

*Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.

5

Image 5
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser Electric Water Heater Safe INSTALLATION, USE and Service General Safety Table of Contents Introduction Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsRemoving the Old Water Heater Installation InstructionsFacts to Consider About Convertible Lower Element Facts to Consider About the LocationInsulation Blankets Water Piping Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Converting the Lower Element Page Wiring Page Wiring Diagrams Temperature Regulation Service and AdjustmentTemperature Settings Upper and Lower Thermostat Adjustments ThermostatsDraining Temperature-Pressure Relief Valve OperationAnode Rod Inspection Element Cleaning/Replacement Thermostat Removal/ReplacementPage Page Service Drain Valve Washer ReplacementOperational Conditions TroubleshootingStart Up Conditions AIR in HOT Water Faucets Water is TOO HOT Leakage Checkpoints Model Numbers Repair Parts ListBuss Bar Kit 9001591 153.326862 Gallon Short 153.326863 Page Page MY-HOME