T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

Table 3. Thermostat Installer Setup Options. (Continued)

 

Installer Setup

Factory Setting

 

Other Choices

 

 

Number (Press

(Press ! or " key to change)

 

Select

Time key to

 

 

 

 

Actual

Display

Description

Display

Description

change)

Setting

Adaptive

13

0

Adaptive Intelligent

1

Conventional recovery

Intelligent

 

 

Recovery™

 

(system starts recovery at

 

Recovery™

 

 

control is activated

 

programmed time).

 

control.

 

 

(system starts

 

 

 

 

 

 

early so setpoint is

 

 

 

 

 

 

reached by start of

 

 

 

 

 

 

program period).

 

 

 

Degree

14

1

Temperature is

Temperature is displayed in

 

temperature

 

 

displayed in °C

 

°C

 

display

 

 

 

 

 

 

Not Used.

15

 

 

 

 

 

 

 

Clock format.

16

0

12-hour clock

1

24-hour clock format.

 

 

 

 

format.

 

 

 

Not Used.

17 thru 23

 

 

 

 

 

 

 

Outdoor

24

0

No outdoor

1

Outdoor temperature is

 

temperature

 

 

temperature is

 

displayed. Needs a

 

display (models

 

 

displayed.

 

C7089B1000 Outdoor

 

with OT

 

 

 

 

Temperature Sensor to

 

terminals).

 

 

 

 

operate.

 

Not Used.

25 thru 28

 

 

 

 

 

 

 

O/B terminal

29

0

O/B terminal

1

O/B terminal energized for

 

energized in

 

 

energized for

 

reversing valve in heating

 

heating or

 

 

reversing valve in

 

 

 

cooling.

 

 

cooling.

 

 

 

Deadband

30

3

Heating and

4 thru 10

Heating and cooling

 

 

 

 

cooling setpoints

 

setpoints can be set no

 

 

 

 

can be set no

 

closer than the chosen

 

 

 

 

closer than 3°F

 

value:

 

 

 

 

(1.5°C).

 

4—4°F (2°C)

 

 

 

 

 

 

5—5°F (2.5°C)

 

 

 

 

 

 

6—6°F (3°C)

 

 

 

 

 

 

7—7°F (3.5°C)

 

 

 

 

 

 

8—8°F (4°C)

 

 

 

 

 

 

9—9°F (4.5°C)

 

 

 

 

 

 

10—10°F (5°C)

 

Not Used.

31 and 32

 

 

 

 

 

 

 

Minimum off

33

5

5 minute minimum

0 thru 4

Minimum number of minutes

 

time for the

 

 

off time for the

 

(0 thru 5) the compressor

 

compressor.

 

 

compressor.

 

will be off between calls for

 

 

 

 

 

 

the compressor.

 

Temperature

34

90

Highest heating

40 thru 89

Temperature range (1°F

 

range stops in

 

 

setpoint setting.

 

increments) of heating

 

heating.

 

 

 

 

setpoint settings.

 

Temperature

35

45

Lowest cooling

46 thru 99

Temperature range (1°F

 

range stops in

 

 

setpoint setting.

 

increments) of cooling

 

cooling.

 

 

 

 

setpoint settings

 

Not Used.

36

 

 

 

 

 

 

 

5

69-1406—1

Image 5
Contents When Installing this Product InstallationWallplate Installation ApplicationLast WiringMounting Thermostat Using Thermostat Keys Fig SettingsSystem settings control the thermostat operation LED IndicationTemperature Settings Installer SetupProgrammed time Control System starts Display DescriptionAdaptive Ultraviolet UV Setting Current Day and Time Installer SYSTEM-TESTEmergency Heating Equipment System Test Time ∆ Installer System Test OptionsCooling Equipment System Test System Test Time ∆Press the Time ∆ key to access the thermostat information Outdoor Temperature Sensor Select ModelsThermostat Information CheckoutTroubleshooting Guide Symptom Possible Cause Action Troubleshooting GuideTemperature Incorrectly Between the thermostat and sensor Automation and Control Solutions