Honeywell T8611G installation instructions Installer SYSTEM-TEST, Setting Current Day and Time

Page 7

T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

Setting Current Day and Time

1.Press Set Current Day/Time.

NOTE: On initial powerup or after an extended power loss, 1:00 pm flashes on the display until a key is pressed.

INSTALLER SYSTEM-TEST

Use the Installer System Test to check the thermostat operation. Refer to Table 4 for a list of the available system-tests.

 

 

 

Set Day/Time

Set Current

Time

Set Program

PM

 

 

 

Day/Time

 

 

Mon

M14619

2.Press Day until the current day is displayed.

NOTE: Sun=Sunday, Mon=Monday,

Tue=Tuesday, Wed=Wednesday,

Thu=Thursday, Fri=Friday, Sat=Saturday

.

 

 

Set Day/Time

Time

Set Program

PM

Day

 

Tue

M14620

3.Press Time or Time until the current time is displayed.

NOTE: Tapping the Set Current Day/Time changes the time in one-hour increments.

.

Time

Set Day/Time

AM

Time

Set Program

Tue

M14621

NOTE: If the current time is Daylight Savings Time, press Daylight Time until DST is displayed.

.

Set Day/Time

AM

Daylight

Time

Set Program

 

 

Time

 

Tue

DST

M14622

4.Press Run Program.

System

Heat

 

 

 

AM

 

Run

Time

Set Program

 

 

 

 

 

Fan

Program

 

 

 

 

Tue

 

Room

 

 

Wake

DST

Auto

M14623

CAUTION

Equipment Damage Hazard.

Minimum compressor off-time is bypassed during INstaller System Test.

Avoid cycling compressor quickly.

To start the sytem-test:

Press and hold the increase ! and decrease " keys at the same time until 10 appears. All segments of the display will be displayed before the 10 appears. See Fig. 11 and 12.

Table 4. Tests Available In Installer System Test.

Test Number

 

System Test Description

10-19

 

 

 

 

 

Heating equipment can be turned

 

 

 

 

 

 

 

on and off.

 

 

30-39

 

 

 

 

 

Cooling equipment can be turned on

 

 

 

 

 

 

 

and off.

 

 

40-49

 

 

 

 

 

Fan equipment can be turned on

 

 

 

 

 

 

 

and off.

 

 

60 0 to 60

19

 

 

Keyboard keys test.

 

70-79

 

 

 

 

 

Thermostat information including

 

 

 

 

 

 

 

date code and software versions are

 

 

 

 

 

 

 

displayed.

 

 

Wait

 

 

Setting

 

Set Program

 

Set Day/Time

Temporary

Em Heat

Recovery

 

 

 

 

AM

 

 

 

 

 

 

Off

Hold for

 

 

 

 

PM

 

Cool

 

 

 

 

 

 

 

 

Auto

Filter

 

 

 

 

 

 

 

 

 

Em Ht

 

Aux Ht

Days

 

 

 

 

 

 

 

Fan

Mon Tue Wed Thu Fri Sat Sun

Repl Batt Room

Outdoor

On

Wake Leave

 

Return

Sleep

DST Heat Cool

Auto

 

 

 

 

 

 

 

 

 

 

 

M14559

Fig. 11. Display of all LCD segments.

.

M14612

Fig. 12. Display of test number

Refer to Table 5 for the directions and results of the specific tests.

NOTE: Press Time to advance to the next test and Time to go back to the previous test. Press Run Program to exit the system test

7

69-1406—1

Image 7
Contents Application InstallationWhen Installing this Product Wallplate InstallationMounting Thermostat WiringLast LED Indication SettingsUsing Thermostat Keys Fig System settings control the thermostat operationTemperature Settings Installer SetupAdaptive Display DescriptionProgrammed time Control System starts Ultraviolet UV Setting Current Day and Time Installer SYSTEM-TESTSystem Test Time ∆ Installer System Test OptionsEmergency Heating Equipment System Test Time ∆ Cooling Equipment System TestCheckout Outdoor Temperature Sensor Select ModelsPress the Time ∆ key to access the thermostat information Thermostat InformationTroubleshooting Guide Symptom Possible Cause Action Troubleshooting GuideTemperature Incorrectly Between the thermostat and sensor Automation and Control Solutions