T8611G CHRONOTHERM® IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
|
| Table 5. Installer System Test Options. |
Keys to | Test | Description |
Press | Number | |
Heating Equipment | ||
Time ∆ | 10 | Enter heating equipment System Test. |
! | 11 | |
|
|
|
! | 12 | |
|
|
|
" | 11 | |
|
|
|
" | 10 | |
|
|
|
Emergency | Heating Equipment System Test | |
Time ∆ | 20 | Change from heating to emergency heating equipment System Test. |
! | 21 | Emergency heat come on. |
|
|
|
" | 20 | Emergency heat turn off. |
|
|
|
Cooling Equipment System Test | ||
Time ∆ | 30 | Change from heating or emergency heating to cooling equipment System Test. |
! | 31 | Cool and system fan come on. |
|
|
|
" | 30 | Cool and system fan turn off. |
|
|
|
Fan Equipment | System- | Test |
Time ∆ | 40 | Change from cooling to fan equipment System Test. |
! | 41 | Fan comes on. |
|
|
|
" | 40 | Fan turns off. |
|
|
|
Key Operation |
| |
Time ∆ | 60 | Change from fan to key operation System Test. |
NOTE: Press any key and the displayed numbers will change. Press Time ∇ to go to the previous test and Time ∆ to go to the next test. The Run Program key will not exit this test. Press Time ∆ or Time ∇ and then the Run Program key to exit.