must be properly set by the installer. (Only those marked with an asterisk * below are available to the homeowner.) The homeowner configurations are described in the owner’s manual. A special procedure allows entry into the configuration mode. Description of each selection and how to use the configuration mode follows.

CONFIGURATION OPTIONS − SUMMARY Option 01 — Equipment Type

Option 02 — Clean Filter Timer Adjustment

Option 03* — Fahrenheit/Centigrade Selection Option 04 — Fan (G) on with W/W1 Selection

Option 05 — Room Air Temperature Sensing (programmable models only)

Option 06 — Cooling Lockout Below 55_F/13_C Selection (only available if outdoor air sensor is present)

Option 07 — Zoning

Option 08 — Auxiliary Heat Lockout Temperature Setting (only available when heat pump is used and when outdoor air temperature sensor is present)

Option 10 — Reversing Valve

Option 11 — Adjustable Setpoint Deadband

Option 12 — Smart Recovery (programmable models only) Option 13 — Room Temperature Offset Adjustment Option 15 — Enable Auto Mode

Option 16 — Cycles Per Hour Option 17 — Time Between Stages

22

Image 24
Contents Installation Instructions Page Table of Contents Safety ConsiderationsIntroduction Installation Considerations PowerOutdoor Temperature Sensor ModelsRemote Indoor Temperature Sensor Two−Piece Thermostat ConfigurationInstallation Wiring− T6−NAC / T6−NHP Carton Contents AC/HP Control LocationInstall AC/HP Control Electrical Operation HazardUnit Damage Hazard Two−Piece Installation − Press Tabs to Remove Backplate− Take Apart − Backplate Mounting Relays − Secure Wires to Terminal Strip − Attach Display to Backplate − Equipment Control Module on Equipment − Standoff − Cover on Equipment Control Module Single−Piece Installation − Equipment Control Module Set AC/HP Control Configuration − Reattach Display ModulePage To Enter Configuration Mode Configuration Options -Selection Option 01 Equipment TypeOption 02 Clean Filter Timer Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 − Remote Room Sensor − Parallel Wiring Option 06 Cooling Lockout Below 55FOption 08 Auxiliary Heat Lockout Temperature Option 07 ZoningOption 10 Reversing Valve Option 11 Deadband Setting Between Heat & Cool Option 12 Smart RecoveryOption 13 Room Air Temperature Offset Adjust Option 15 Enable Auto ModeOption 18 Backlight Configuration Option 16 Maximum Cycles Per HourOption 17 Time Between Equipment Stages Option 20 Outdoor Air Temperature Offset Adjustment Option 21 Keypad Lockout programmable models onlyOption 21 Keypad Lockout non−programmable models only Page Option 24 Programmable/Non−Programmable Option 25 Number of Programmable PeriodsOption 26 Minimum Cooling Setpoint Option 27 Maximum Heating Setpoint Option 28 UV Light ReminderOption 30 Programmable Fan programmable models only Page Option 33 Single or Two−Piece Installation Option 41 Variable Speed BlowerOption 44 Super Comfort Heat Option 99 Reset to Factory Defaults System START−UP and Checkout Final Settings Energy Star Default SchedulePage Timers Operational InformationVacation programmable models only Cycle Timer Ten−Minute Staging TimerDefrost Equipment On Indicators Heat/Cool Setpoints Desired TemperatureThree−Minute Minimum on Time Auto ChangeoverEmergency Heat Mode Programmable Fan programmable models onlyDry Contact Troubleshooting Error CodesTemperature Offset After Power Cycle RelaysPage Equipment Configuration Outputs − Equipment Configuration Outputs Wiring Diagrams − Display to Equipment Control Module ConnectionWiring DIAGRAMScont − Fan Coil shown with Auxiliary Connection #1 − Fan Coil with Air Conditioner Indicates connection may not be required/available − Furnace with Air Conditioner − Thermostat with Dry Contact Control for Run Time Outdoor Sensor Remote Room Air Conditioner − Single−stage Furnace with Air Conditioner and Split Power Thermostat Configuration Record Mode SettingsConfiguration Options Option Keypad Lockout Page Catalog No IIT6-PAC-03

T6-PAC, T6-NAC, T6-NHP, T6-PHP specifications

The Bryant T6 series is a line of advanced heating and cooling systems designed to offer exceptional comfort, energy efficiency, and cutting-edge technology for residential and commercial applications. The series includes models such as T6-PHP, T6-NHP, T6-NAC, and T6-PAC, each tailored to meet specific heating, ventilation, and air conditioning (HVAC) needs.

The Bryant T6-PHP (Heat Pump) model stands out with its dual-fuel capability, providing both electric heat pump operation and backup gas heating. This versatility allows for optimal energy use depending on outdoor temperatures, ensuring lower utility bills and consistent comfort. It also features high-efficiency ratings, making it an environmentally friendly choice, while its variable-speed compressor allows for quiet operation and precise temperature control. The T6-PHP is equipped with smart technology that allows homeowners to monitor and adjust settings remotely through mobile applications.

Similarly, the T6-NHP (Natural Gas Heat Pump) variant is designed for regions where natural gas is readily available. This model combines the efficiency of heat pump technology with the reliability of natural gas heating. The T6-NHP features intelligent performance diagnostics that help to optimize operation and reduce maintenance costs, ensuring that the system runs smoothly throughout its lifespan.

The T6-NAC (Air Conditioner) model focuses on delivering exceptional cooling performance. With enhanced energy efficiency ratings, it utilizes environmentally friendly refrigerants and is designed to reduce electricity consumption while providing consistent indoor comfort. The T6-NAC features advanced airflow technology that allows for better distribution of cooled air, improving overall comfort levels in the home.

Lastly, the T6-PAC (Packaged Air Conditioner) is a self-contained system that combines cooling and heating in a single unit, making it ideal for homes with limited installation space. This all-in-one unit features a compact design while still delivering high efficiency and performance. With a programmable thermostat and integration with smart home technology, the T6-PAC ensures user-friendly operation and convenient control.

In summary, the Bryant T6 series leverages state-of-the-art technology, energy-efficient designs, and user-friendly features to provide superior HVAC solutions. Whether it's the versatile heating capabilities of the T6-PHP and T6-NHP or the efficient cooling of the T6-NAC and T6-PAC, these units are engineered to deliver unmatched comfort and reliability for today's homeowners.