Bryant T6-PHP, T6-PAC, T6-NAC, T6-NHP Single−stage Furnace with Air Conditioner and Split Power

Page 59

WIRING DIAGRAMS(cont.)

Thermostat

 

 

 

 

 

 

RVS/Heat Stage 2

O/B W2

 

Heat Stage 1

 

 

W/W1

 

Compressor Low

 

 

Y1

 

Compressor High

 

 

Y/Y2

 

Fan

 

 

G

 

24VAC Hot Heating

 

 

Rh

 

24VAC Hot Cooling

 

 

Rc

 

 

 

 

 

 

 

Dry Contact 1

 

 

D1

 

 

 

 

 

 

 

Dry Contact 2

 

 

D2

 

24VAC Common

 

 

C

 

Outdoor Air Temp

 

 

OAT

 

Remote Room Sensor

 

 

RRS

 

OAT/RRS Com

 

 

OAT/RRS

 

 

 

 

 

 

 

Single-Stage

Furnace

W/W1

Y/Y2

G

R

COM

Outdoor Sensor *

Remote Room

Sensor *

Single-Stage

Air Conditioner

Y

R*

COM

* Indicates connection may not be required/available.

NOTE: Rc/Rh jumper is cut on the Equipment Control Module.

A09160

Fig. 25 − Single−stage Furnace with Air Conditioner and Split Power

57

Image 59
Contents Installation Instructions Page Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsModels Outdoor Temperature SensorTwo−Piece Thermostat Configuration Remote Indoor Temperature SensorWiring InstallationAC/HP Control Location − T6−NAC / T6−NHP Carton ContentsElectrical Operation Hazard Install AC/HP ControlUnit Damage Hazard − Press Tabs to Remove Backplate Two−Piece Installation− Take Apart − Backplate Mounting Relays − Secure Wires to Terminal Strip − Attach Display to Backplate − Equipment Control Module on Equipment − Standoff − Cover on Equipment Control Module Single−Piece Installation − Equipment Control Module − Reattach Display Module Set AC/HP Control ConfigurationPage To Enter Configuration Mode Option 01 Equipment Type Configuration Options -SelectionOption 04 Fan G On With W/W1 Option 02 Clean Filter TimerOption 03 Fahrenheit/Centigrade Option 06 Cooling Lockout Below 55F − Remote Room Sensor − Parallel WiringOption 10 Reversing Valve Option 08 Auxiliary Heat Lockout TemperatureOption 07 Zoning Option 15 Enable Auto Mode Option 11 Deadband Setting Between Heat & CoolOption 12 Smart Recovery Option 13 Room Air Temperature Offset AdjustOption 17 Time Between Equipment Stages Option 18 Backlight ConfigurationOption 16 Maximum Cycles Per Hour Option 21 Keypad Lockout programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout non−programmable models only Page Option 26 Minimum Cooling Setpoint Option 24 Programmable/Non−ProgrammableOption 25 Number of Programmable Periods Option 30 Programmable Fan programmable models only Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Page Option 44 Super Comfort Heat Option 33 Single or Two−Piece InstallationOption 41 Variable Speed Blower Option 99 Reset to Factory Defaults System START−UP and Checkout Energy Star Default Schedule Final SettingsPage Vacation programmable models only TimersOperational Information Defrost Cycle TimerTen−Minute Staging Timer Auto Changeover Equipment On IndicatorsHeat/Cool Setpoints Desired Temperature Three−Minute Minimum on TimeDry Contact Emergency Heat ModeProgrammable Fan programmable models only Relays TroubleshootingError Codes Temperature Offset After Power CyclePage Equipment Configuration Outputs − Equipment Configuration Outputs − Display to Equipment Control Module Connection Wiring DiagramsWiring DIAGRAMScont − Fan Coil shown with Auxiliary Connection #1 − Fan Coil with Air Conditioner Indicates connection may not be required/available − Furnace with Air Conditioner − Thermostat with Dry Contact Control for Run Time Outdoor Sensor Remote Room Air Conditioner − Single−stage Furnace with Air Conditioner and Split Power Mode Settings Thermostat Configuration RecordConfiguration Options Option Keypad Lockout Page Catalog No IIT6-PAC-03