Bryant T6-NAC, T6-PAC, T6-NHP, T6-PHP Final Settings, Energy Star Default Schedule

Page 41

TO TEST FAN

Fan button switches FAN icon between AUTO and On. While On is displayed, G output will be energized, turning fan on. On some fan coils, fan continues to operate for 90 sec after G signal is removed.

Final Settings

Be sure to press DONE to exit installer setup mode. If the system is to be left in operation after installation is complete, use MODE button to select between HEAT, COOL, or AUTO to provide desired operation of heating, cooling, or auto.

On the programmable models, the default setpoints and programmed schedule conform to the Energy Starr requirements of the U.S. Department of Energy for both heating and cooling. These provide energy saving temperature settings. Refer to Table 1.

Table 1 – Energy Star Default Schedule

SCHEDULE

HEAT

COOL

 

 

 

Wake 6:00 AM

68_F/20_C

78_F/26_C

 

 

 

Day 8:00 AM

60_F/16_C

85_F/29_C

 

 

 

Evening 5:00 PM

68_F/20_C

78_F/26_C

 

 

 

Sleep 10:00 PM

60_F/16_C

82_F/28_C

 

 

 

If the programmed schedule is to be used, make sure the triangle icon next to the FOLLOW SCHEDULE icon is turned on. Pressing the Schedule button will cycle the triangle icon through the FOLLOW SCHEDULE, HOLD and VACATION selections.

39

Image 41
Contents Installation Instructions Page Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsModels Outdoor Temperature SensorTwo−Piece Thermostat Configuration Remote Indoor Temperature SensorWiring InstallationAC/HP Control Location − T6−NAC / T6−NHP Carton ContentsElectrical Operation Hazard Install AC/HP ControlUnit Damage Hazard − Press Tabs to Remove Backplate Two−Piece Installation− Take Apart − Backplate Mounting Relays − Secure Wires to Terminal Strip − Attach Display to Backplate − Equipment Control Module on Equipment − Standoff − Cover on Equipment Control Module Single−Piece Installation − Equipment Control Module − Reattach Display Module Set AC/HP Control ConfigurationPage To Enter Configuration Mode Option 01 Equipment Type Configuration Options -SelectionOption 04 Fan G On With W/W1 Option 02 Clean Filter TimerOption 03 Fahrenheit/Centigrade Option 06 Cooling Lockout Below 55F − Remote Room Sensor − Parallel WiringOption 10 Reversing Valve Option 08 Auxiliary Heat Lockout TemperatureOption 07 Zoning Option 12 Smart Recovery Option 11 Deadband Setting Between Heat & CoolOption 13 Room Air Temperature Offset Adjust Option 15 Enable Auto ModeOption 17 Time Between Equipment Stages Option 18 Backlight ConfigurationOption 16 Maximum Cycles Per Hour Option 21 Keypad Lockout programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout non−programmable models only Page Option 26 Minimum Cooling Setpoint Option 24 Programmable/Non−ProgrammableOption 25 Number of Programmable Periods Option 30 Programmable Fan programmable models only Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Page Option 44 Super Comfort Heat Option 33 Single or Two−Piece InstallationOption 41 Variable Speed Blower Option 99 Reset to Factory Defaults System START−UP and Checkout Energy Star Default Schedule Final SettingsPage Vacation programmable models only TimersOperational Information Defrost Cycle TimerTen−Minute Staging Timer Heat/Cool Setpoints Desired Temperature Equipment On IndicatorsThree−Minute Minimum on Time Auto ChangeoverDry Contact Emergency Heat ModeProgrammable Fan programmable models only Error Codes TroubleshootingTemperature Offset After Power Cycle RelaysPage Equipment Configuration Outputs − Equipment Configuration Outputs − Display to Equipment Control Module Connection Wiring DiagramsWiring DIAGRAMScont − Fan Coil shown with Auxiliary Connection #1 − Fan Coil with Air Conditioner Indicates connection may not be required/available − Furnace with Air Conditioner − Thermostat with Dry Contact Control for Run Time Outdoor Sensor Remote Room Air Conditioner − Single−stage Furnace with Air Conditioner and Split Power Mode Settings Thermostat Configuration RecordConfiguration Options Option Keypad Lockout Page Catalog No IIT6-PAC-03

T6-PAC, T6-NAC, T6-NHP, T6-PHP specifications

The Bryant T6 series is a line of advanced heating and cooling systems designed to offer exceptional comfort, energy efficiency, and cutting-edge technology for residential and commercial applications. The series includes models such as T6-PHP, T6-NHP, T6-NAC, and T6-PAC, each tailored to meet specific heating, ventilation, and air conditioning (HVAC) needs.

The Bryant T6-PHP (Heat Pump) model stands out with its dual-fuel capability, providing both electric heat pump operation and backup gas heating. This versatility allows for optimal energy use depending on outdoor temperatures, ensuring lower utility bills and consistent comfort. It also features high-efficiency ratings, making it an environmentally friendly choice, while its variable-speed compressor allows for quiet operation and precise temperature control. The T6-PHP is equipped with smart technology that allows homeowners to monitor and adjust settings remotely through mobile applications.

Similarly, the T6-NHP (Natural Gas Heat Pump) variant is designed for regions where natural gas is readily available. This model combines the efficiency of heat pump technology with the reliability of natural gas heating. The T6-NHP features intelligent performance diagnostics that help to optimize operation and reduce maintenance costs, ensuring that the system runs smoothly throughout its lifespan.

The T6-NAC (Air Conditioner) model focuses on delivering exceptional cooling performance. With enhanced energy efficiency ratings, it utilizes environmentally friendly refrigerants and is designed to reduce electricity consumption while providing consistent indoor comfort. The T6-NAC features advanced airflow technology that allows for better distribution of cooled air, improving overall comfort levels in the home.

Lastly, the T6-PAC (Packaged Air Conditioner) is a self-contained system that combines cooling and heating in a single unit, making it ideal for homes with limited installation space. This all-in-one unit features a compact design while still delivering high efficiency and performance. With a programmable thermostat and integration with smart home technology, the T6-PAC ensures user-friendly operation and convenient control.

In summary, the Bryant T6 series leverages state-of-the-art technology, energy-efficient designs, and user-friendly features to provide superior HVAC solutions. Whether it's the versatile heating capabilities of the T6-PHP and T6-NHP or the efficient cooling of the T6-NAC and T6-PAC, these units are engineered to deliver unmatched comfort and reliability for today's homeowners.