Bryant T6-PHP, T6-PAC, T6-NAC Wiring Diagrams, Display to Equipment Control Module Connection

Page 51

WIRING DIAGRAMS

Display module

Display module wall mount

 

 

 

 

 

 

 

 

 

 

 

 

 

V+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vg

 

 

 

 

 

 

 

 

 

 

V+

 

 

 

V+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vg

 

 

 

Vg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equipment Control Module

Fan Coil

 

 

 

V+

 

 

Vg

O

RVS/Heat Stage 2

O/B W2

W3

Heat Stage 1

W/W1

W2

Compressor

Y/Y2

Y

Not Used

Y1

 

Fan

G

G

24VAC Hot Heating

Rh

R

24VAC Hot Cooling

Rc

 

Dry Contact 1

D1

 

Dry Contact 2

D2

 

24VAC Common

C

COM

Outdoor Air Temp

OAT

 

Remote Room Sensor

RRS

Outdoor Sensor *

OAT/RRS Com

OAT/RRS

Remote Room

 

 

Sensor *

Heat Pump

O

W2

Y

R

COM

* Indicates connection may not be required/available.

A09174

Fig. 17 − Display to Equipment Control Module Connection

49

Image 51
Contents Installation Instructions Page Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsModels Outdoor Temperature SensorTwo−Piece Thermostat Configuration Remote Indoor Temperature SensorWiring InstallationAC/HP Control Location − T6−NAC / T6−NHP Carton ContentsElectrical Operation Hazard Install AC/HP ControlUnit Damage Hazard − Press Tabs to Remove Backplate Two−Piece Installation− Take Apart − Backplate Mounting Relays − Secure Wires to Terminal Strip − Attach Display to Backplate − Equipment Control Module on Equipment − Standoff − Cover on Equipment Control Module Single−Piece Installation − Equipment Control Module − Reattach Display Module Set AC/HP Control ConfigurationPage To Enter Configuration Mode Option 01 Equipment Type Configuration Options -SelectionOption 02 Clean Filter Timer Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 Option 06 Cooling Lockout Below 55F − Remote Room Sensor − Parallel WiringOption 08 Auxiliary Heat Lockout Temperature Option 07 ZoningOption 10 Reversing Valve Option 15 Enable Auto Mode Option 11 Deadband Setting Between Heat & CoolOption 12 Smart Recovery Option 13 Room Air Temperature Offset AdjustOption 18 Backlight Configuration Option 16 Maximum Cycles Per HourOption 17 Time Between Equipment Stages Option 21 Keypad Lockout programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout non−programmable models only Page Option 24 Programmable/Non−Programmable Option 25 Number of Programmable PeriodsOption 26 Minimum Cooling Setpoint Option 27 Maximum Heating Setpoint Option 28 UV Light ReminderOption 30 Programmable Fan programmable models only Page Option 33 Single or Two−Piece Installation Option 41 Variable Speed BlowerOption 44 Super Comfort Heat Option 99 Reset to Factory Defaults System START−UP and Checkout Energy Star Default Schedule Final SettingsPage Timers Operational InformationVacation programmable models only Cycle Timer Ten−Minute Staging TimerDefrost Auto Changeover Equipment On IndicatorsHeat/Cool Setpoints Desired Temperature Three−Minute Minimum on TimeEmergency Heat Mode Programmable Fan programmable models onlyDry Contact Relays TroubleshootingError Codes Temperature Offset After Power CyclePage Equipment Configuration Outputs − Equipment Configuration Outputs − Display to Equipment Control Module Connection Wiring DiagramsWiring DIAGRAMScont − Fan Coil shown with Auxiliary Connection #1 − Fan Coil with Air Conditioner Indicates connection may not be required/available − Furnace with Air Conditioner − Thermostat with Dry Contact Control for Run Time Outdoor Sensor Remote Room Air Conditioner − Single−stage Furnace with Air Conditioner and Split Power Mode Settings Thermostat Configuration RecordConfiguration Options Option Keypad Lockout Page Catalog No IIT6-PAC-03