3 - Troubleshooting

3 - Troubleshooting

Test Equipment Required

Table 3-1 lists the test equipment required to troubleshoot the power supply. Recommended models are listed.

Table 3-1. Test Equipment Required for Troubleshooting

Type

Purpose

Recommended Model

GPIB Controller

To communicate with the supply via the

HP Series 300

 

GPIB interface

 

Digital Voltmeter

To check various voltage levels

Agilent 3458A

Oscilloscope

To check waveforms and signal levels

Agilent 54504A/54111A

Electronic Load

To test operation of current circuit

Agilent 6060B

IC Test Clips

To access IC pins

AP Products No. LTC

Ammeter/Current

To measure output current

Guildline 9230/15

Shunt

 

 

Overall Troubleshooting

Overall troubleshooting procedures for the power supply are given in the Figure 3-1. The procedures first check that neither an AC input, nor a bias supply failure is causing the problem and that the supply passes the turn-on self test (error annunciator stays off). The normal turn-on, self-test indications are described in the "Checkout Procedure" in Chapter 3 of the User's Guide.

If the supply passes the self test and there are no obvious faults, you should perform the verification procedures in Chapter 2 from the front panel to determine if any functions are not calibrated or are not operating properly. Then program and read back a voltage via the GPIB to see if the supply responds properly to bus commands. If the supply fails any of the tests, you will be directed to the applicable flow chart or troubleshooting procedure.

Flow Charts

Troubleshooting flow charts are given in Figure 3-1 sheets 1-10. Several flow charts make reference to the test points listed in Chapter 6. The circuit locations of the test points are shown on the schematics and on the component location diagrams in Chapter 6.

24

Page 24
Image 24
Agilent Technologies 6634B, 66332A, 6633B, 6632B service manual Overall Troubleshooting, Flow Charts, Test Equipment Required