Agilent Technologies 6633B, 6634B, 66332A, 6632B 1Sheet 10. No Current Limit, Troubleshooting

Models: 6632B 6633B 66332A 6634B

1 82
Download 82 pages 25.5 Kb
Page 34
Image 34
Figure 3-1 Sheet 10. No Current Limit

3 - Troubleshooting

Continued from sheet 2

CC_Prog, R360,

 

 

 

Check A2 Interface

 

 

 

 

 

No

 

 

 

 

 

 

 

Board

 

 

 

 

-4.8V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Imon_H, U309A-6

 

 

 

Drop across R473

 

 

 

Check R473

 

No

 

No

 

 

~+3.5V

 

 

 

~0.25V

 

 

 

?

 

 

 

 

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

Yes

 

 

 

 

 

Check Positive Current

Control Circuit

Check High Range

Current Monitor

Amplifier

Figure 3-1 Sheet 10. No Current Limit

34

Page 34
Image 34
Agilent Technologies 6633B, 6634B, 66332A, 6632B service manual 1Sheet 10. No Current Limit, Troubleshooting