Agilent Technologies 6634B Performance Test Record Forms, Verification and Performance Tests

Models: 6632B 6633B 66332A 6634B

1 82
Download 82 pages 25.5 Kb
Page 20
Image 20
Performance Test Record Forms

2 - Verification and Performance Tests

Performance Test Record Forms

Model Agilent 66332A OR

Report No _______________

Date __________________

Agilent6632B

 

 

 

 

 

 

 

 

 

 

 

Test Description

Minimum

Results*

Maximum

Measurement

 

Specs.

 

 

Specs.

 

Uncertainty

Constant Voltage Tests

 

 

 

 

 

 

 

 

 

 

 

Voltage Programming and Readback

 

 

 

 

 

 

 

 

 

 

 

Low Voltage (0V) Vout

− 10 mV

 

__________

+ 10 mV

 

1.6 ∝V

Front Panel Display Readback

Vout

3 mV

__________

Vout + 3 mV

1.6

 

 

 

 

 

 

V

High Voltage (Full Scale) Vout

19.980 V

 

__________

20.020 V

335

 

 

 

 

 

 

V

Front Panel Display Readback

Vout

9 mV

__________

Vout + 9 mV

335

 

 

 

 

 

 

V

Load Effect

− 2 mV

 

__________

+ 2 mV

 

20 ∝V

Source Effect

− 0.5 mV

__________

+ 0.5 mV

20 ∝V

PARD (Ripple and Noise)

 

 

 

 

 

 

 

 

 

 

 

Peak-to-Peak

 

0 mV

 

__________

+ 3 mV

 

872 ∝V

RMS

 

0 mV

 

__________

+ 0.3 mV

50

 

 

 

 

 

 

 

 

 

 

V

Transient Response

 

 

 

 

 

 

 

 

 

 

 

Voltage in 100 ∝s

 

0 mV

 

__________

+ 20 mV

 

3 mV

Constant Current Tests

 

 

 

 

 

 

 

 

 

 

 

Current Programming and Readback

 

 

 

 

 

 

 

 

 

 

 

Low current (0A) Iout

− 2.0 mA

__________

+ 2.0 mA

15.2 ∝A

Readback Accuracy @ Iout

Iout

0.5 mA

__________

Iout + 0.5 mA

15.2

 

 

 

 

 

A

High Current (Full Scale) Iout

4.9955 A

__________

5.0045 A

818.7

 

 

 

 

A

Readback Accuracy @ Iout

Iout

10.5 mA

__________

Iout + 10.5 mA

818.7

 

 

 

 

 

A

Current Sink Readback

Isink − 11.1mA

__________

Isink + 11.1mA

818.7 ∝A

20 mA Range Current Readback

 

 

 

 

 

 

 

 

 

 

 

Readback Accuracy @ 0 A

− 2.5 ∝A

__________

+ 2.5 ∝A

0.1 ∝A

Readback Accuracy @ + 20 mA

Iout

22.5

__________

Iout + 22.5

1.7

 

 

A

 

A

 

A

Readback Accuracy @ − 20 mA

Iout

22.5

__________

Iout + 22.5

1.7

 

 

A

 

A

 

A

PARD (Current Ripple and Noise)

 

 

 

 

 

 

 

 

 

 

 

RMS

 

0 mA

 

__________

+ 2.0 mA

250 ∝A

Load Effect

− 1.0 mA

__________

+ 1.0 mA

2.5 ∝A

Source Effect

− 0.5 mA

__________

+ 0.5 mA

2.5 ∝A

* Enter your test results in this column

 

 

 

 

 

 

 

 

 

 

 