Agilent Technologies 6632B, 6634B, 66332A, 6633B 1Sheet 11. Unit Does Not OV, Troubleshooting

Models: 6632B 6633B 66332A 6634B

1 82
Download 82 pages 25.5 Kb
Page 35
Image 35
Figure 3-1 Sheet 11. Unit Does Not OV

Program the output voltage and current to the full scale value and the OV to 1/2.

OV_prog ~+2V @

 

 

 

 

A2 Interface Board or

 

 

No

 

 

 

 

 

 

cable W7 defective

 

R350

 

 

 

 

 

 

 

 

 

 

 

 

 

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U306B-8

 

 

 

 

Check R350, C335 and

 

 

No

 

 

 

 

 

 

U306B

 

~+2V

 

 

 

 

 

 

 

 

 

 

 

 

 

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

U306B-7

 

 

 

 

 

 

 

 

 

 

 

 

Check R349, R351,

 

 

No

 

 

 

~+4V

 

 

 

R356, C336 and U306

 

 

 

 

 

 

 

 

 

?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

U306B-2,

 

 

 

 

 

 

 

 

 

 

 

 

Check U306B

 

 

OV_DETECT*,

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

See note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Troubleshooting - 3

Reset the OV (Shift, Prot Clr) and observe the OV_SCR* signal. Each time OV is reset Manual background the unit will generate another OV signal. The OV pulse (OV_SCR*)

is approximately 5us long.

OV_SCR* pulse @

R438 low 5us

?

Yes

Q318D Collector pulses high 5us

?

NoManual background

NoManual background

Check Q318B, R441, A2 Interface Board

Check Q318A, B and D and associated circuits

Yes

Check A1CR342

Figure 3-1 Sheet 11. Unit Does Not OV

35

Page 35
Image 35
Agilent Technologies 6632B, 6634B, 66332A, 6633B service manual 1Sheet 11. Unit Does Not OV, Troubleshooting