SVA-SERIES—TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

TABLE 5. TROUBLESHOOTING

 

 

 

 

 

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

 

 

No power to motor.

Verify unit is plugged in to proper outlet. Verify extension

 

 

 

cords are properly plugged in and are not cut or pinched.

 

 

 

Verify power is available at outlet. (check main switch or

 

Motor does not start.

 

breaker.)

 

 

Burnt out switch (rare). One or more

Replace or complete connections as needed.

 

 

internal connections open.

 

 

 

 

 

 

 

Pinched wire.

Use screw driver to adjust wires. MAKE CERTAIN not to

 

 

 

damage the insulation on the wires.

 

Housing halves do not seat

Switch Plate or Filter Cover not seated

Seat Switch Plate properly in Housing slot.

 

together properly

 

properly.

 

 

 

 

 

 

Power Cord Grommet not seated properly.

Seat grommet in Housing slot.

 

 

 

 

 

Rattlling/growling noise from

Rear bearing failure.

Replace bearing.

 

rear of housing area.

 

 

 

 

 

 

 

 

 

Worn coupler.

Disconnect coupler and turn motor on. If noise goes away

 

Rattling/growling noise from

 

replace coupler. If noise remains, check forward bearing.

 

forward housing area.

Forward bearing failure.

Replace bearing.

 

 

 

 

 

 

 

SVA-SERIES • VIBRATOR MOTOR — PARTS AND OPERATION MANUAL — REV. #1 (06/13/07) — PAGE 17