CyberPower PR50000LCDRTXL5U Definition Fro Illuminated Lcd Indicators, Multifunction Lcd Readout

Page 7
DEFINITION FRO ILLUMINATED LCD INDICATORS

DEFINITION FRO ILLUMINATED LCD INDICATORS

MULTIFUNCTION LCD READOUT

The multifunction LCD readout provides ready access to power/battery condition vitals, such as: Runtime, Load, Temperature, and much more.

The screen is also rotatable so the UPS can be used in either rack mount or vertical/tower orientation.

BASIC OPERATION

Screen toggle – To toggle through the status screens press the Select button which is located directly next to the LCD.

Screen illumination– After 30 seconds of inactivity, the LCD backlight will automatically turn off to conserve energy. Keeping the LCD screen lit at all times is not an option on this UPS.

Select Button

If the LCD screen is not lit pressing the Select button once will turn the LCD on. If the LCD screen is lit, then pressing the Select button once will toggle through the status screens.

Pressing and holding the Select button for four (4) seconds while UPS is in Normal operation will initiate the Self Test.

Pressing and holding the Select button for four (4) seconds while UPS is in Battery/Offline mode will activate Silent Mode on the UPS.

Select Button

MAIN FEATURES

Load Level: The total load of the connected equipment shown in 20% increments.

Battery Capacity: The battery’s current charge level shown in 20% increments.

Normal Icon: This icon appears when the UPS is working under normal conditions.

Silent icon: This icon appears when the UPS is in silent mode. During Silent mode, the unit’s alarm does not sound until the Battery Capacity falls to < 20%.

Overload icon: This icon appears when the Battery/Surge outlets on the UPS are overloaded. The UPS will also sound an alarm at this point. To clear the overload, the total load of the connected equipment must be less than the unit’s maximum capability. The easiest way to correct this problem is to remove noncritical equipment from the Battery/Surge outlets.

Fault icon: This icon appears if there is an internal problem with the UPS. Please contact Technical Support if this icon is lit.

Battery Icon: This icon appears when the UPS is operating using battery power. The UPS will also sound alarms (two short beeps followed by a pause) when this icon is lit. When the Battery Icon is lit and the Battery Capacity falls to 20% the frequency of the alarms will increase indicating that the UPS batteries are nearly out of power. If this occurs, it is recommended that you either restore AC power, or manually power down your equipment that may be negatively affected by sudden power loss.

Automatic Voltage Regulation (AVR) icon: This icon appears when the UPS is automatically correcting AC input line voltage without using battery power. This is a normal, automatic operation of your UPS, and no action is required. The AVR in this UPS continuously conditions the power to a nominal 208V output to connected equipment. In the event of a complete power loss, severe brownout, or over voltage, the UPS relies on its internal battery back up to supply a consistent 208V output.

6

Image 7
Contents PR5000LCDRTXL5U/ PR6000LCDRTXL5U User’s ManualK01-0000124-02 UNPACKING IMPORTANT SAFETY INSTRUCTIONSAUTOMATIC VOLTAGE REGULATORAVR INSTALLING YOUR UPS SYSTEMSYSTEM BLOCK DIAGRAM HARDWARE INSTALLATION GUIDEFRONT/REAR PANEL DESCRIPTION BASIC OPERATIONRACKMOUNT INSTALLATION HARDWARE INSTALLATIONHARDWARE INSTALLATION SAFETY PRECAUTIONSELECTRICAL INSTALLATION VERTICAZL/TOWER INSTALLATIONSAFETY PRECAUTIONS BASIC OPERATION DEFINITION FRO ILLUMINATED LCD INDICATORSMAIN FEATURES MULTIFUNCTION LCD READOUTTOGGLE SCREENS Replacement Batteries MAINTENANCEBattery Replacement Safety PrecautionsTECHNICAL SPECIFICATIONS Limited Warranty and Connected Equipment Guarantee PRODUCT REGISTRATION & WARRANTYProduct Registration FREQUENTLY ASKED QUESTIONS FAQs SERVICE INFORMATIONNEED ADDITIONAL HELP?