TOGGLE SCREENS

DEFINITION FRO ILLUMINATED LCD INDICATORS

TOGGLE SCREENS

Input Voltage

The Input Voltage screen displays the AC voltage that the UPS system is receiving from the utility wall receptacle. This can be used as a diagnostic tool to identify poor quality input power. Units are listed in V (Volts).

Output Frequency

The Output Frequency screen displays the current frequency at which the UPS is operating. Units are listed in Hz (Hertz).

Load Capacity

Similar to the Load/Current Level screen, this displays the total load/current of the connected equipment expressed as a percentage (%).

Temperature

The Temperature screen displays the internal temperature of the UPS in degrees Centigrade. Normal ranges are 0-40. If the temperature exceeds 40, additional methods should be implemented to cool the UPS (i.e. air conditioning, additional ventilation, isolation from other heat producing equipment, etc.).

Output Voltage

The Output Voltage screen measures, the AC voltage that the UPS is providing to your connected equipment via the UPS outlets. Units are listed in V (Volts).

Estimated Runtime

The Estimated Runtime Screen displays how many minutes of runtime can be expected of the UPS if it were to experience a power outage. Note: The number displayed may be less than actual runtimes for low loads.

Battery Capacity

The Battery Capacity screen displays the battery’s current charge level and is expressed as a percentage (%) of the battery’s total capacity of 100%.

Temperature

The Temperature screen displays the internal temperature of the UPS in degrees Fahrenheit. Normal ranges are 32-104. If the temperature exceeds 104, additional methods should be implemented to cool the UPS (i.e. air conditioning, additional ventilation, isolation from other heat producing equipment, etc.)

7

Image 8
Contents K01-0000124-02 User’s ManualPR5000LCDRTXL5U/ PR6000LCDRTXL5U IMPORTANT SAFETY INSTRUCTIONS UNPACKINGINSTALLING YOUR UPS SYSTEM SYSTEM BLOCK DIAGRAMHARDWARE INSTALLATION GUIDE AUTOMATIC VOLTAGE REGULATORAVRBASIC OPERATION FRONT/REAR PANEL DESCRIPTIONHARDWARE INSTALLATION HARDWARE INSTALLATIONSAFETY PRECAUTIONS RACKMOUNT INSTALLATIONSAFETY PRECAUTIONS VERTICAZL/TOWER INSTALLATIONELECTRICAL INSTALLATION DEFINITION FRO ILLUMINATED LCD INDICATORS MAIN FEATURESMULTIFUNCTION LCD READOUT BASIC OPERATIONTOGGLE SCREENS MAINTENANCE Battery ReplacementSafety Precautions Replacement BatteriesTECHNICAL SPECIFICATIONS Product Registration PRODUCT REGISTRATION & WARRANTYLimited Warranty and Connected Equipment Guarantee NEED ADDITIONAL HELP? SERVICE INFORMATIONFREQUENTLY ASKED QUESTIONS FAQs