TECHNICAL SPECIFICATIONS
Model | PR5000LCDRTXL5U |
| PR6000LCDRTXL5U | |
Configuration |
|
|
| |
| Capacity (VA) | 5000VA |
| 6000VA |
| Capacity (Watts) | 4000W |
| 4500W |
| GreenPower | UPS™ Bypass | ||
Input |
|
|
| |
| Nominal Input Voltage |
| 208V | |
| Input Voltage Range |
| ||
| Input Adjustable Voltage Range |
| ||
| Frequency Range | 50/60Hz +/- 3Hz | ||
| Input Plug Type |
| NEMA | |
| Cold Start |
| Yes | |
| Output |
|
|
|
| UPS Outlets | (3) NEMA | ||
| On Battery Output Voltage | Pure Sinewave, 208V +- 5% | ||
| On Battery Output Frequency |
| ||
| Transfer Time (Typically) |
| 4ms | |
| Overload Protection | On Utility: Circuit Breaker; On Battery: Internal Current Limiting | ||
Data line Protection |
|
|
| |
| Surge Protection | 2430J |
| 2430J |
| Phone / Network Protection | RJ11/RJ45 (One In/One Out) | ||
Battery |
|
|
| |
| Specifications |
| (16) 12V/9.0AH | |
| Sealed, Maintenance Free |
| Yes | |
| User Replaceable |
| Yes | |
| Recharge Time (Typically) |
| 4 hours | |
Status Indicators |
|
|
| |
| Indicator LEDs | Power On, LCD Display (Using Battery, AVR, Load Level, Battery Level) | ||
| Audible Alarms | On Battery, Low Battery, Overload | ||
| Environment |
|
|
|
| Operating Temperature | 32℉ to 104℉ ( 0℃ to 40℃) | ||
| Operating Relative Humidity | 0 to 95% | ||
Management |
|
|
| |
| Self Test, | |||
| Connectivity Ports | (1) USB, (2) Serial | ||
| SNMP/HTTP Capable |
| Yes | |
Software |
|
|
| |
| Power Management Software | PowerPanel® Business Edition | ||
Physical |
|
|
| |
| Dimensions (LxWxH) (in) | 25.25" x 17" x 8.75" | ||
| Weight (lbs) | 222 |
| 226 |
Safety |
|
|
| |
| Conformance Approvals | FCC Class A certified, UL 1778,CSA C22.2 No. | ||
Warranty |
|
|
| |
| Product Warranty |
| 3 years Limited | |
| Connected Equipment Guarantee |
| 300,000 |
9