PRODUCT SPECIFICATIONS/LISTING & CODE APPROVAL

PRODUCT SPECIFICATIONS:

 

 

 

 

Gas Pressure (Inches W.C.)

Models Number

Gas Type

Control Type

Max Btu

Max

Min

Manifold

 

 

 

 

 

 

 

724BV4536NV

Natural Gas

Milli-volt

50000

10.5

4.0

3.5

724BV4536PV

Propane/LPG

Milli-volt

50000

13.0

11.0

10.0

724BV5142NV

Natural Gas

Milli-volt

50000

10.5

4.0

3.5

724BV5142PV

Propane/LPG

Milli-volt

50000

13.0

11.0

10.0

724BV4536NE

Natural Gas

Electronic

50000

10.5

4.0

3.5

724BV4536PE

Propane/LPG

Electronic

50000

13.0

11.0

10.0

724BV5142NE

Natural Gas

Electronic

50000

10.5

4.0

3.5

724BV5142PE

Propane/LPG

Electronic

50000

13.0

11.0

10.0

 

 

 

 

 

 

 

High Altitude Installations

Gas rate shown above is for altitudes up to 2000 ft. When installing this fireplace at an elevation above 2000 ft, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1000 ft above sea level, unless the heating value of the gas has been reduced. Consult your local dealer or gas authority for assistance in determining the proper orifice at your location.

LISTING & CODE APPROVAL:

The above models have been tested and certified by the applicable laboratories to the standards listed below.

MODEL

LAB.

TYPE

CERTIFICATION STANDARD

724BV4536 Series

CSA

Decorative Vented Gas Fireplace

ANSI Z21.50-2000•CSA 2.22-2000

724BV5142 Series

CSA

Decorative Vented Gas Fireplace

ANSI Z21.50-2000•CSA 2.22-2000

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is convertible for use with other gases, when a certified kit is used.