Monessen Hearth 7000 Series operating instructions General Troubleshooting

Models: 7000 Series

1 36
Download 36 pages 12.05 Kb
Page 35
Image 35
GENERAL TROUBLESHOOTING:

GENERAL TROUBLESHOOTING:

1.

Glass Soots

A.

Flame impingement

Install log set per the instructions

 

 

 

 

on logs

Inspect the injector and air intake area. Make sure this area

 

 

 

 

 

 

 

 

 

 

does not have any blockage from debris and clean.

 

 

 

 

 

Check gas supply

 

2. Poor draft due to

A.

Too much offset.

Reduce offset and/or raise termination.

 

 

venting

 

 

 

 

 

 

 

B.

Too many elbows

Reduce number of elbows

 

 

 

 

 

 

 

 

 

C. Vent height too short

Raise vent

 

 

 

 

 

 

 

 

 

D. Vent too close to

Raise vent

 

 

 

 

roof line

 

 

 

 

 

E.

Blockage is

Remove blockage

 

 

 

 

restricting venting

 

 

 

 

 

 

capacity

 

 

 

 

 

F.

Incorrect vent type

Replace with proper B-Vent

 

 

 

 

 

 

 

 

 

 

G.

Venting has been

Replace with proper size

 

 

 

 

constructed with too

 

 

 

 

 

 

large or too small

 

 

 

 

 

 

vent.

 

 

 

 

 

H.

More than one

Construct a single venting system for each appliance

 

 

 

 

appliance is using

 

 

 

 

 

 

one venting system.

 

 

 

3. Poor draft due to

A.

Cap obstructed by a

Remove or open enclosure or raise cap above it.

 

 

termination cap.

 

decorative enclosure.

 

 

 

 

 

B.

Cap is crushed,

Replace cap

 

 

 

 

damaged or missing.

 

 

 

4. Poor draft due to

A.

Buildings, trees, roof

Maintain proper clearances and heights to external

 

 

ext. environment.

 

lines interfering with

obstructions; Beware of overhangs.

 

 

 

 

venting.

 

 

 

 

 

B.

Wind

Use cap designed for high winds; raise venting height.

 

 

 

 

 

 

 

 

 

C. Vent exposed to cold

Insulate chase.

 

 

 

 

chase.

 

 

 

 

 

D. Vent exposed to cold

Enclose vent within home.

 

 

 

 

weather.

 

 

 

5. Poor draft due to

A.

Negative air pressure.

To test for negative air pressure, open a window in the room

 

 

internal

 

 

with the fireplace to see if the unit starts drafting correctly.

 

 

environment.

 

 

 

 

 

 

 

 

 

Make sure the damper system is in the open position.

 

 

 

 

 

 

 

6.

Unit shuts down

A.

Blockage or

Check for and remove blockage and light pilot following

 

 

prematurely.

 

restriction in venting.

lighting instructions.

 

 

 

 

 

 

 

 

 

B. Damper system

Open damper system and light pilot following lighting

 

 

 

 

closed.

instructions.

 

 

 

 

 

 

 

 

 

 

 

 

If damper system will not operate, call contractor.

 

 

 

 

 

 

 

 

 

 

 

 

34

 

Page 35
Image 35
Monessen Hearth 7000 Series operating instructions General Troubleshooting