Electronic Pilot Ignition Wiring:

GAS LINE AND ELECTRICAL INSTALLATION

Pilot must be lit and the valve control knob turned to the “ON” position. Meter leads must be connected to the TP and the TH/TP terminals on the control valve.

Turn RS-ON-OFF switch to the “ON” position.

9 If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve.

9 If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading.

Turn RS-ON-OFF switch to the “RS ” position and wall switch to “ON”

9 If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve.

9 If meter is reading less than 175 millivolt, then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading.

Electronic Pilot Ignition Wiring:

WARNINGDo not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or be destroyed.

Do not connect 110-120 VAC to the Remote Wall Switch. The appliance will malfunction or be destroyed.

Figure 14: Wiring Diagram for Electronic Ignition System

Remote Wall Switch

Position the wall switch. Refer to Figure 14: Wiring Diagram for Electronic Ignition System. Do not extend beyond the 15 feet of wire.

18