Sinclair ASH-13AK, ASH-09AK service manual Noise Silencing Protection

Page 16

If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temperature resumes to normal,the outdoor fan will be restarted.

Noise Silencing Protection

If the unit is stopped by pressing ON/OFF, the reversal valve will be stopped after 2-minute lag; or 2 minutes wil l be delayed upon mode switching.

Over current product

Theovercurrent protection is the same with the the over current protection under cool mode.

Fan mode

Under FA N mode, only the indoor fan runs at setting speed.The RUN indicator will be bright. Double 8 module indicator will display the setting temperature. When stand by, the power indicator is bright but the unit does not run.

Auto Mode

Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temperature. For protection function, same as under cooling and heating mode.

Other controls

Timer function

Ordinary Timer setting:

timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs.

Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs.

Timer setting for hour:

Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, When timer on has arrived, the system will run at pressetting mode.

Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on, to set up timer off, when the timer off arrived, the system will stop to work.

Timer setting change:

When system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run at last setting status.

When system is running, at the same time to set up Timer on and Timer off, the system will keep the present setting status, when time arrived, system will stop to work.

When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start to work.

Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop.

Auto button

After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off. Buzzer

The controller is powered on and detect the signal received, the buzzer will beep.

Sleep function

Under cooling or dehumidifying mode, the preset temperature will automatically rise by 1, ine hour after setting of sleep program and rise by 1after 2hours.

Tpreset

Preset temp. Tpreset

 

Tpreset

Tpreset 1hour

2hours

2hours above

Under heating mode, the preset temperature will automatically decrease by 1 one hour after setting of sleep program and decrease by another 1after 2hours.

Image 16
Contents ASH-09AK, ASH-13AK Page 1Ph 220~240V 50Hz R410aTechnical specifications Highly Indoor unit Outdoor unitOutline and installation dimension Outline and installation dimensions of outdoor unit Electrical circuit diagram 2Basic Functions Protection Other controls Page Manual 2 of functions of remote controller RunStop Noise Silencing Protection Turbo function Disassemble the guide louver Disassemble the front panel, filterDisassemble the front case Disassemble the electric box Disassemble the electric coverDisassemble water tray Disassembling the evaporator Disassembling motor and cross flow fanDisassemble the front panel, filter Support Disassembling the evaporator Conventional 09 Disassembly procedures for indoor unit Disassemble the electric box cover Disassembling the evaporator Conventional 12 Disassembly procedures for indoor unit Disassemble the Light Board and electric cover Disassembling the evaporator Disassemble Top Cover Disassemble Big HandleDisassemble Rear Grill Disassemble Right Side Plate Disassemble Front PanelDisassemble Electric Box Disassemble Motor and Motor Support Disassemble Axial Flow FanDisassemble Four-way Valve Disassemble Gas and Liquid Valves Disassemble CapillaryDisassemble Compressor Failure and analysis Is good. Heat insulation must also be provided for Wrong connection Re-wrap and make it tight Page King Series Page Contents ASH-09AK ASH-09AK Indoor Unit ASH-13AK ASH-13AK Indoor Unit Explosive view and spare parts list of outdoor unit ASH-09AK Outdoor Unit ASH-13AK ASH-13AK Outdoor Unit