Sinclair ASH-13AK, ASH-09AK service manual Other controls

Page 12

3.Other controls

1. Memory function

Memory contents: Mode, up and down swing, Light, Setting temp., Setting fan speed, Ordinary setting Fahrenheit/Centigrade, after powered off, and powered on, it will run at the memory contents.

If no timer setting function in last remote control order, the system will memorize the last remote control order, the system will memorize the last remote control order and work with last remote control setting.

In the last remote control order, there is ordinary timer function, if power off happen beffore the timer arrived, the system will memorize the last remote control timer function, and will recalculate.

If there is timer function in last remote control order, but timer has arrive, system will run at timer on or timer offand power off, after repowered on, the system will run at the mode before power off.

Timer function

1.Ordinary Timer setting:

Timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs.

Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is 0.5-24hrs.

Timer setting for hour:

Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, when timer on has arrived, the system will run at pressetting mode.

Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on, to set up timer off, when the timer off arrived, the system will stop to work.

Timer setting change:

Whensystem is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run at last setting status.

When system is running, at the same time to set up Timer on and Timer off, the system will keep the present setting status, when time arrived, system will stop to work.

When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start to work.

Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop.

(3) Auto button

After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off.

(4) Buzzer

The controller is powered on and detect the signal received, the buzzer will beep.

(5) Sleep function

Under cooling or dehumidifying mode, the preset temperature will automatically rise by 1, ine hour after setting of sleep program and rise by 1after 2hours.

Under heating mode, the preset temperature will automatically decrease by 1 one hour after setting of sleep program and decrease by another 1after 2hours.

Image 12
Contents ASH-09AK, ASH-13AK Page 1Ph 220~240V 50Hz R410aTechnical specifications Highly Indoor unit Outdoor unitOutline and installation dimension Outline and installation dimensions of outdoor unit Electrical circuit diagram 2Basic Functions Protection Other controls Page Manual 2 of functions of remote controller RunStop Noise Silencing Protection Turbo function Disassemble the front panel, filter Disassemble the guide louverDisassemble the front case Disassemble the electric cover Disassemble the electric boxDisassemble water tray Disassembling the evaporator Disassembling motor and cross flow fanDisassemble the front panel, filter Support Disassembling the evaporator Conventional 09 Disassembly procedures for indoor unit Disassemble the electric box cover Disassembling the evaporator Conventional 12 Disassembly procedures for indoor unit Disassemble the Light Board and electric cover Disassembling the evaporator Disassemble Big Handle Disassemble Top CoverDisassemble Rear Grill Disassemble Front Panel Disassemble Right Side PlateDisassemble Electric Box Disassemble Axial Flow Fan Disassemble Motor and Motor SupportDisassemble Four-way Valve Disassemble Capillary Disassemble Gas and Liquid ValvesDisassemble Compressor Failure and analysis Is good. Heat insulation must also be provided for Wrong connection Re-wrap and make it tight Page King Series Page Contents ASH-09AK ASH-09AK Indoor Unit ASH-13AK ASH-13AK Indoor Unit Explosive view and spare parts list of outdoor unit ASH-09AK Outdoor Unit ASH-13AK ASH-13AK Outdoor Unit