LG Electronics LSN180HE, LSN090CE, LSU120CE, LSU090HE Remote Control Operations, Operation Mode

Page 40

Operation

RemoteControlOperations

The controls will look like the following.

Signal transmitter

5

 

 

1

6

 

 

 

 

 

 

3

4

 

 

 

2

 

 

10

 

CANCEL

 

 

 

9

7

OFF

SET

ON

12

11

 

AUTO CLEAN

8

 

 

17

13

 

 

18

 

 

14

 

 

 

15

 

 

16

Flip-up door (opened)

Operation Mode

Cooling Operation

Auto Operation or Auto Changeover

Healthy Dehumidification Operation

Heating Operation

• Cooling Model(), Heat Pump Model( )

1. START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

2. OPERATION MODE SELECTION BUTTON Used to select the operation mode.

3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature.

4. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS.

5. JET COOL

Used to start or stop the speed cooling.(speed cooling operates super high fan speed in cooling mode.)

6. CHAOS SWING BUTTON

Used to stop or start louver movement and set the desired up/down airflow direction.

7.ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping operation. (See page 22)

8.TIME SETTING BUTTONS

Used to adjust the time. (See page 22)

9.TIMER SET/CANCEL BUTTON

Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 22)

10.SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation. (See page 22)

11.AIR CIRCULATION BUTTON

Used to circulate the room air without cooling or heating. (See page 23)

12.ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature.

13.NEO PLASMA(OPTIONAL)

Used to start or stop the plasma-purification function. (See page 20)

14.HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL)

Used to set the desired horizontal airflow direction.

15.RESET BUTTON

Used prior to resetting time.

16.2nd F Button

Used prior to using modes printed in blue at the bottom of buttons. (See page 21)

17.AUTO CLEAN (OPTIONAL) Used to set Auto Clean mode.

18.˚C TO ˚F SWITCHING BUTTON

Used to switch temperature reading from Centigrade to Fahrenheit.

40Room Air Conditioner

Image 40
Contents Room Air Conditioner Table of Contents Safety Precautions InstallationDo not modify or extend the power cord Be sure not to do Be sure to follow the instructionOperation Moisture may condense and wet or damage furnishings Keep level even when installing the product Low refrigerant levels may cause product failureOccupants Salt spray directlySolvents, etc On the product. outdoor unitDo not drink the water drained from the unit DisuseReplace all the batteries in the remote Symbols Used in this Manual DimensionsIndoor Unit Model Btu Series Dimension Mminch 109042.9 30011.8 1787.0 Outdoor Unit 9k, 12k18k, 24k DIMFeatures IntroductionInstallation Parts InstallationInstallation Tools Installation Map Bushing-SleeveConfirm The Refrigerant This Product Contains R-410A RefrigerantRooftop Installations Select The Best LocationIndoor unit Outdoor unitPiping Length And Elevation Evap Moz/ftHow To Mount Installation Plate Drill a Hole In The WallFlaring Work Cut the pipes and the cableBurrs removal Putting nut onIndoor unit installation Connecting The PipingIndoor Wrap the insulation material around the connecting portion Tighten the flare nut with a wrenchInsert the connecting cable into the indoor unit Indoor unit installationConnection Indoor Correct case Incorrect caseConnection Of The Drain Hose Connection Of Piping -OutdoorWiring Diagram Connection Of The CableRoom Air Conditioner Checking The Drainage Drain pipingForming The Piping Seal small openings around pipings with a gum type sealerAir Purging Air purging With Vacuum PumpPreparation Leak testEvacuation Finishing the jobCharging Btu/hPrepare remote control Test RunningSettlement of outdoor unit Evaluation of the performanceCooling Mode Operation Healthy Dehumidification ModeOperation Function of ControlsHeating Mode Operation Defrost ControlSleep Timer Operation Chaos Natural Wind ModeJet Cool Mode Operation C/O Model Jet Cool Mode Operation H/P ModelForced operation Test operationAuto restart Protection of the evaporator pipe from frostingSelf-diagnosis Function Display FunctionHeating Model Remote Control Operations Operation ModeDisassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover Troubleshooting Guide Refrigeration Cycle DiagramCooling Only Models Cooling & Heating ModelsWay, 3-way Valve Way Valve Liquid SideProcedure Pumping DownBalance Refrigerant of the 3-way Valve Vacuum pump Gas Charging After EvacuationMethod of using graph Method of using equationAccording to Indoor & Outdoor Temperature Additional gas chargingCycle Parts Trouble analysisElectronic Parts 9k model Product does not operate at allElectronic Parts 18k model Product is not operate with the remote controller Compressor/Outdoor Fan are unable to drive.9k Model Compressor/Outdoor Fan are unable to drive.18k Model When indoor Fan does not operate NectorWhen Vertical Louver does not operate When a comunication error occurs Phenomena in case of connecting error Indoor UnitOutdoor Unit Schematic Diagram Electric Control DeviceOutdoor 9k, 12k Outdoor 18k, 24k Wiring Diagram Models 9kC/O Models 12kH/P, 12kC/O, H/P Models 18kC/O Models 18kH/P, 24kC/O, H/P Components Location Outdoor9k, 12k Outdoor18k, 24k 6871A20681 6871A20680Product Specifications Cooling OnlyCooling & Heating LS090HE LS120HE LS180HE LS240HEExploded View Outdoor Unit 9k, 12k Btu/h Seriess 435512 Outdoor Unit 18kH/P, 24k Seriess W0CZZ-2Replacement Parts List Parts List IndoorLSN180CE Parts List Outdoor LSU120HEReplacement Parts List LSU240HE No A20462V
Related manuals
Manual 83 pages 52.83 Kb