LG Electronics LSU180CE, LSN090CE, LSU120CE, LSU090HE, LSU090CE, LSN180CE, LSN120HE, LSN180HE LSU240HE

Page 82

Replacement Parts List

Parts List (Outdoor)

LOCATION

DESCRIPTION

 

PART No.

 

REMARKS

No.

LSU240CE

LSU180HE

LSU240HE

 

 

 

 

 

 

 

 

137213-1

PANEL ASSEMBLY,SIDE

1A00202F

1A00202F

1A00202F

R

 

 

 

 

 

 

137213-2

PANEL ASSEMBLY,SIDE

3A02284Y

3A02284Y

3A02284Y

R

 

 

 

 

 

 

263230-1

THERMISTOR ASSEMBLY

6323A20002L

6323A20002L

6323A20002L

R

 

 

 

 

 

 

263230-2

THERMISTOR ASSEMBLY

6323A20016A

6323A20016A

6323A20016A

R

 

 

 

 

 

 

430410

BASE ASSEMBLY,OUTDOOR

3041AP2741G

3041AP2741G

3041AP2741G

R

 

 

 

 

 

 

435300

GRILLE,REAR

1A00208D

1A00208D

1A00208D

R

 

 

 

 

 

 

435301

GRILLE,DISCHARGE

3530A20007J

3530A20007J

3530A20007J

R

 

 

 

 

 

 

435511

COVER ASSEMBLY,CONTROL(OUTDOOR)

3551AR7184T

3551AR7184T

3551AR7184T

R

 

 

 

 

 

 

435512

COVER ASSEMBLY,TOP(OUTDOOR)

3H03266H

3H03266H

3H03266H

R

 

 

 

 

 

 

437210

PANEL ASSEMBLY,FRONT(SUB)

1A00197C

1A00197C

1A00197C

R

 

 

 

 

 

 

447910

BARRIER ASSEMBLY,OUTDOOR

4791A30004H

4791A30004H

4791A30004H

R

 

 

 

 

 

 

55211G

TUBE ASSEMBLY,CONDENSER(OUT)

5211A34008B

5211A34008B

5211A34008B

R

 

 

 

 

 

 

552203-1

VALVE,SERVICE

2H02479B

2H02479B

2H02479B

R

 

 

 

 

 

 

552203-2

VALVE,SERVICE

5220A20013C

5220A20013C

5220A20013C

R

 

 

 

 

 

 

546810

MOTOR,UNCLASSIFIED

4681A20008E

4681A20008E

4681A20008E

R

 

 

 

 

 

 

549610

BRACKET ASSEMBLY,MOTOR(OUTDOOR)

2A01035T

2A01035T

2A01035T

R

 

 

 

 

 

 

550140

DAMPER,COMPRESSOR

4H00982E

4H00982E

4H00982E

R

 

 

 

 

 

 

552112

TUBE ASSEMBLY,CONDENSER(IN)

5211A34007A

5211A34007A

5211A34007A

R

 

 

 

 

 

 

552202

VALVE, REVERSE

5220AR3228E

5220AR3228E

5220AR3228E

R

 

 

 

 

 

 

552116

TUBE ASSEMBLY,REVERSE

5211A24108B

5211A24108B

5211A24108B

R

 

 

 

 

 

 

554160-1

COMPRESSOR SET,KOREA

2520UGHK2AA

2520UGHK2AA

2520UGHK2AA

R

 

 

 

 

 

 

554160-2

COMPRESSOR SET,KOREA

2520UGKK2AA

2520UGKK2AA

2520UGKK2AA

R

 

 

 

 

 

 

554031

CONDENSER ASSEMBLY,BENDING

5403A20066F

5403A20066F

5403A20066F

R

 

 

 

 

 

 

566000

SWITCH, PRESSURE

6600L000013

6600L000013

6600L000013

R

 

 

 

 

 

 

559010

FAN ASSEMBLY,PROPELLER

1A00195B

1A00195B

1A00195B

R

 

 

 

 

 

 

567502-1

OVERLOAD PROTECT

6750U-L048A

6750U-L048A

6750U-L048A

R

 

 

 

 

 

 

567502-2

OVERLOAD PROTECT

6750U-L035A

6750U-L035A

6750U-L035A

R

 

 

 

 

 

 

561410

SOLENOID

-

6141AR3733R

6141AR3733R

R

 

 

 

 

 

 

649950

CASE ASSEMBLY,CONTROL(OUTDOOR)

4995A20383L

4995A20383L

4995A20383L

R

 

 

 

 

 

 

668711

PWB(PCB) ASSEMBLY,MAIN(OUTDOOR)

6871A10184F

6871A10184F

6871A10184F

R

 

 

 

 

 

 

W0CZZ-1

CAPACITOR,DRAWING

6120AR2194F

6120AR2194F

6120AR2194F

R

 

 

 

 

 

 

W0CZZ-2

CAPACITOR,DRAWING

3A00988B

3A00988B

3A00988B

R

 

 

 

 

 

 

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request. (GCSC WEBSITE http://biz.LGservice.com)

82Room Air Conditioner

Image 82
Contents Room Air Conditioner Table of Contents Do not modify or extend the power cord Safety PrecautionsInstallation Be sure not to do Be sure to follow the instructionOperation Moisture may condense and wet or damage furnishings Keep level even when installing the product Low refrigerant levels may cause product failureSolvents, etc OccupantsSalt spray directly On the product. outdoor unitDo not drink the water drained from the unit DisuseReplace all the batteries in the remote Symbols Used in this Manual DimensionsIndoor Unit Model Btu Series Dimension Mminch 109042.9 30011.8 1787.0 Outdoor Unit 9k, 12k18k, 24k DIMFeatures IntroductionInstallation Parts InstallationInstallation Tools Installation Map Bushing-SleeveConfirm The Refrigerant This Product Contains R-410A RefrigerantIndoor unit Rooftop InstallationsSelect The Best Location Outdoor unitPiping Length And Elevation Evap Moz/ftHow To Mount Installation Plate Drill a Hole In The WallBurrs removal Flaring WorkCut the pipes and the cable Putting nut onIndoor unit installation Connecting The PipingIndoor Wrap the insulation material around the connecting portion Tighten the flare nut with a wrenchInsert the connecting cable into the indoor unit Indoor unit installationConnection Indoor Correct case Incorrect caseConnection Of The Drain Hose Connection Of Piping -OutdoorWiring Diagram Connection Of The CableRoom Air Conditioner Checking The Drainage Drain pipingForming The Piping Seal small openings around pipings with a gum type sealerPreparation Air PurgingAir purging With Vacuum Pump Leak testEvacuation Finishing the jobCharging Btu/hSettlement of outdoor unit Prepare remote controlTest Running Evaluation of the performanceOperation Cooling Mode OperationHealthy Dehumidification Mode Function of ControlsHeating Mode Operation Defrost ControlJet Cool Mode Operation C/O Model Sleep Timer OperationChaos Natural Wind Mode Jet Cool Mode Operation H/P ModelAuto restart Forced operationTest operation Protection of the evaporator pipe from frostingSelf-diagnosis Function Display FunctionHeating Model Remote Control Operations Operation ModeDisassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover Cooling Only Models Troubleshooting GuideRefrigeration Cycle Diagram Cooling & Heating ModelsWay, 3-way Valve Way Valve Liquid SideProcedure Pumping DownBalance Refrigerant of the 3-way Valve Vacuum pump Gas Charging After EvacuationAccording to Indoor & Outdoor Temperature Method of using graphMethod of using equation Additional gas chargingCycle Parts Trouble analysisElectronic Parts 9k model Product does not operate at allElectronic Parts 18k model Product is not operate with the remote controller Compressor/Outdoor Fan are unable to drive.9k Model Compressor/Outdoor Fan are unable to drive.18k Model When indoor Fan does not operate NectorWhen Vertical Louver does not operate When a comunication error occurs Phenomena in case of connecting error Indoor UnitOutdoor Unit Schematic Diagram Electric Control DeviceOutdoor 9k, 12k Outdoor 18k, 24k Wiring Diagram Models 9kC/O Models 12kH/P, 12kC/O, H/P Models 18kC/O Models 18kH/P, 24kC/O, H/P Components Location Outdoor9k, 12k Outdoor18k, 24k 6871A20681 6871A20680Product Specifications Cooling OnlyCooling & Heating LS090HE LS120HE LS180HE LS240HEExploded View Outdoor Unit 9k, 12k Btu/h Seriess 435512 Outdoor Unit 18kH/P, 24k Seriess W0CZZ-2Replacement Parts List Parts List IndoorLSN180CE Parts List Outdoor LSU120HEReplacement Parts List LSU240HE No A20462V