Installation

PROCEDURE C

1 Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 15. The use of pliers is recommended.

 

7 13/16"

60°

60°

 

Rear Louvers

 

(Top View)

 

FIG. 15

2

If the wall sleeve already has a rear grille, skip

 

to step 4. If the wall sleeve does not have a

rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 26- 1/2" wide and 15-1/2" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

Place the plastic grille

FIG. 16

 

 

3

Fasten the 4 washer screws to secure the

 

grille to the wall sleeve. If you need plastic nuts

to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.

 

or

Fasten the screws

FIG. 17

20Room Air Conditioner

4

Remove the backing from the Horizontal

 

Insulation strip 13/8 x 13/8 x 273/16 and attach

that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 13/8 x 13/8 x 611/2 and attach that to the inside front of the sleeve as shown below.

Around Insulation

Horizontal Insulation

FIG. 18

5

If the depth of your existing sleeve is less than

 

 

or equal to 18”, skip to step 7. Otherwise, cut

 

 

the baffles and the support blocks according to

 

 

Length "A" in the table below.

 

 

 

Depth"D" of the existing

Length "A"

A

 

 

wall sleeve (inches)

(inches)

A

Support

7822

 

19-3/4

D

22

4

FIG. 19

 

18 D

18-5/8

3/4

 

Block

 

 

18-5/8

D

19-3/4

1-3/4

 

Baffle

 

 

 

 

 

 

 

 

-

6

Remove the backing from the support blocks

 

and attach them to the inside of the wall sleeve454

 

as shown FIG 20. Slide the baffle into slots of

(877)

 

the support blocks

 

 

 

 

 

 

 

 

 

Wall

 

 

 

(7

13/16")

SALES

 

 

 

Baffle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

 

Sleeve

 

 

 

 

 

 

 

 

 

Front

 

Support

DIRECTPTAC

 

 

 

 

 

 

Block

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 20

 

Image 20
Contents Room AIR Conditioner Table of Contents Safety Precautions Always install the trim framesDo not use the power cord near flammable Ptac Direct Sales 877Direct Sales 877 Ensure that the outer case is not damaged by age or wear Do not clean the air conditioner with waterDo not block the inlet or outlet Before cleaning it Plant where it will be Be cautious not to touchDamage Unplug the air conditionerCleaning and maintenance ServiceBefore Operation Preparing for operationElectrical Safety Symbols Used in this ManualIntroduction Electrical DataFor 115V modelElectrical Safety Temporary Use of an Adapter Temporary Use of an Extension CordOperating Instructions Controls Cooling OnlyControls Cooling & Heating OperationVentilation Air DirectionHow to Attach Front Grille to Cabinet Care and MaintenanceAir Filter Cleaning 877 InstallationInstallation Requirements Installation HOW to Install Procedure a SalesProcedure B Top ViewPtac Procedure C 7822Attach them as shown below in Fig Normal Operation Maintenance and ServiceTroubleshooting Memo