LG Electronics AMNC093D4A0(LMN090CE), AMNH123DEA0(LMN120HE) Outdoor Unit Multiple piping models

Page 14

Product Specifications

Outdoor Unit - Multiple piping models

 

Model

 

A3UC363FA0(LMU360CE)

A3UH363FA0(LMU360HE)

 

 

 

 

 

 

 

 

 

 

Cooling Capacity

 

 

Btu/hr

9,000~36,000

9,000~36,000

 

 

 

 

 

 

 

 

 

W

2637~10,550

2637~10,550

 

 

 

kcal/hr

2267~9071

2267~9071

 

 

 

 

 

 

Heating Capacity

 

 

Btu/hr

-

9,000~36,000

 

 

 

 

 

 

 

 

 

W

-

2637~10,550

 

 

 

kcal/hr

-

2267~9071

Input

Cooling

 

W

1320~3680

1320~3680

 

 

 

 

 

 

 

Heating

 

W

-

1410~3340

Running Current(208/230V)

Cooling

 

A

5.9~16.6

5.9~16.6

 

 

 

 

 

 

 

Heating

 

A

-

6.3~15.0

Power Supply

 

 

Ø,V,Hz

1,208/230,60

1,208/230,60

 

 

 

 

 

 

Max. Number of Connectable Indoor Units

 

3

3

Compressor

Type

 

Rotary

Rotary

(Constant)

Model

 

GK141K

GK141K

 

Motor Type

 

 

2 Pole Induction(PSC)

2 Pole Induction(PSC)

 

 

 

 

 

 

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

1430

1430

 

Oil Charge

cc

350Å }10

350Å }10

 

 

 

 

 

 

 

Oil Type

 

FVC68D

FVC68D

 

 

 

 

 

 

 

Capacitor

 

µF/Vac

35 / 370

35 / 370

 

O.L.P Type(model name)

 

External Type

External Type

Compressor

Type

 

Rotary

Rotary

 

 

 

 

 

 

(Constant)

Model

 

GJ230K

GJ230K

 

Motor Type

 

2 Pole Induction(PSC)

2 Pole Induction(PSC)

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

2370

2370

 

 

 

 

 

 

 

Oil Charge

 

cc

700±10

7000±10

 

Oil Type

 

FVC68D

FVC68D

 

Capacitor

 

µF/Vac

50 / 400

50 / 400

 

 

 

 

 

 

 

O.L.P Type(model name)

 

Internal Type

Internal Type

 

 

 

 

 

 

Refrigerant charge

Charge

 

g(oz)

2400

2400

 

Type

 

R410A

R410A

 

Control

 

L.E.V

L.E.V

 

 

 

 

 

 

Coil

Tube Size (OD)

 

inch(mm)

0.276(7.0)

0.276(7.0)

 

 

 

 

 

 

 

Fins per inch

 

18

18

 

No. of Rows & Column/No.

 

2R,48C

2R,48C

Fan motor

Model

 

ARC286B01 * 2

ARC286B01 * 2

 

Output

 

W

102

102

 

Capacitor

 

µF/Vac

2/370

2/370

Fan

Type

 

Propeller

Propeller

 

No. Used / Diameter

 

EA/inch(mm)

2 / 15.7(400)

2 / 15.7(400)

 

 

 

 

 

 

 

Discharge

 

Side / Top

Side

Side

Air Circulation

Outdoor

 

CMM(CFM)

63(2225)

63(2225)

Noise Level(H/L) at 230V

Sound Press,1m

 

dB(A) 1

51

51

 

 

 

 

 

 

SVC Valve

Liquid

 

inch(mm)

1/4 (6..35) * 3EA

1/4 (6..35) * 3EA

 

 

 

 

 

 

 

Gas

 

 

3/8 (9.52) * 3EA

3/8 (9.52) * 3EA

Dimensions

W*H*D

 

inch(mm)

34.3*41.7*12.6 (870*1060*320)

34.3*41.7*12.6 (870*1060*320)

Net Weight

Outdoor

 

kg(lbs)

80(176)

80(176)

 

 

 

 

 

 

Max. Interunit Piping Length

Total of Each Room

 

m

45

45

 

 

 

 

 

 

 

For One Room

 

m

15

15

Max. Installation

Indoor Unit~Outdoor Unit

 

m

7.5

7.5

Height Difference

Indoor Unit~Indoor Unit

 

m

7.5

7.5

 

 

 

 

 

 

Packing Dimension

W*H*D

 

inch(mm)

41.1*44.9*17.3 (1045*1140*440)

41.1*44.9*17.3 (1045*1140*440)

Stuffing Quantity

 

 

20/40ft

51/111

51/111

Notes: 1. Capacities are based on the following conditions:

Cooling: -Indoor Temperature 26.7°C(80.1°F)DB/19.4°C66.9°F)WB -Outdoor Temperature 35°C(95°F)DB/23.9°C(75°F)WB -Interconnecting Piping Length 7.5m

-Level Difference of Zero.

Heating: -Indoor Temperature 21.1°C(70°F)DB/15.6°C(60.1°F)WB -Outdoor Temperature 8.3°C(46.94°F)DB/6.1°C(42.98°F)WB -Interconnecting Piping Length 7.5m

-Level Difference of Zero.

2.Capacities are Net Capacities.

3.: See the page "Combination Table"

4.Due to our policy of innovation some specifications may be changed without notification.

14Multi type Air Conditioner

Image 14
Contents Indoor Unit Room Type Art Cool Type Outdoor Unit A3UH363FA0LMU360HE A3UC363FA0LMU360CETable of Contents Outdoor Unit Model Number NomenclatureIndoor Unit Symbols Used in this Manual Combination tableBe sure not to do Be sure to follow the instruction Safety PrecautionsInstallation Control box securely Cuit and breakerBe sure the installation area does not deteriorate with age Do not place anything on the power cableBe cautious when unpacking OperationSmoke comes from product Nect the power supply cableDo not allow water to run into electric parts Hurricane arrivesInstalling the product When the product is soakedInstall the drain hose to ensure that Keep level even when Not enter the productVents, etc OperationalAir flow Not use harsh detergents, solDo not step on or put anyting on the product. outdoor units Ly. Clean the filter every twoWhen cleaning or maintaining Do not drink the water drained from the productSplit Type Indoor DimensionsIndoor Unit Outdoor Unit Product Specifications Indoor UnitOutdoor Unit Multiple piping models Model A3UC363FA0LMU360CE A3UH363FA0LMU360HEInstallation Tools InstallationInstallation Parts Outdoor unit Rooftop InstallationsSelect the best location Piping length and elevation Multi Piping TypeFixing Installation PlateStandard Type Remove cover pipe and cover side Preparing work for Installation Artcool Type OnlyOpen panel front Drain hose junctionDrill a hole in the wall Sticking the installation guide map and fixing Indoor unitPut an Installation Guide Map on the desired surface Drive the fore plastic anchors into drilled pointsFlaring Work and Connection of Piping Flaring workIndoor Connecting the PipingCheck Wrap the insulation material around the connecting por- tion For left rear piping Plastic bands Insulation material Connection Indoor Panel AssemblyArt Cool Type only Drive two screwsGood case Bad caseRemote Control Preparationoptional Outdoor Outdoor unitConnecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the Outdoor unit Outdoor unitConnection method of the connecting cableExample How to connect wiring to the terminalsConnect the cable to the indoor unit Drain piping Checking the drainageTo check the drainage Forming the piping Preparation Air Purging and EvacuationChecking method Leakage testFinishing the job Repeat evacuation procedure for each indoor unitEvacuation Charging AdditionalTest Running Split, Art Cool TypeHeating Mode Operation Cooling Mode OperationSoft Dry Operation Mode OperationFuzzy Operation for Cooling Defrost ControlHeatingFuzzy Operation Airflow Speed Selection On-Timer OperationOff-Timer Operation Fuzzy Operation for DehumidificationChaos Swing Mode Off-Timer = On-Timer OperationSleep Timer Operation Chaos Natural Wind ModeForced Operation Buzzer Sounding OperationFunction of Indoor Unit Split Type Indoor UnitOperation IndicatorArt Cool Type Indoor Unit DefrostDeice control HeatingFunction of Outdoor Unit 15 2nd F Button Remote Control OperationCooling Model , Heat Pump Model Disassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover To remove the Control Box To remove the Motor To remove the EvaporatorBefore removing the Turbo Fan Split Type Schematic DiagramElectronic Control Device Outdoor Outdoor Unit Schematic Diagram Wiring Diagram Art Cool Type Indoor UnitComponents Locations Bottom ViewArt Cool Type Schematic Diagram Component side Solder side A3UH363FA0LMU360HE Troubleshooting GuideRefrigeration Cycle Diagram A3UC363FA0LMU360CEError Indicator Indoor ErrorOutdoor Error Self-diagnosis FunctionCycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Procedure Specification RemedyProduct doesnt operate with the remote controller Compressor/Outdoor Fan are dont operate Check Point Comp. on Comp. OFFTrouble 4 When indoor Fan does not operate NectorTroubleshooting Guide Indoor air sensor Error CodeCheck Point Indoor inlet pipe sensorPower input AC 230V.Outdoor, Indoor Communication line is shorted at GNDError Title Cause of error Check point & Normal condition Condensor pipe sensor Title Cause of error Check point & Normal conditionOutdoor air sensor Pipe sensorWay, 3-way Valve Way Valve Liguid SideAir purging of the charge hose ProcedurePumping down Set the liquid side valve to the closed positionAll amount of refrigerant leaked Mount the valve caps and the service port capsEvacuation After Evacuation Mount the valve stem nuts and the service port nutGas Charging Connect the gauge to the charging cylinderExploded View & Replacement Parts List S4, SE chassisLMN090HE Parts List S4, SE chassisS4 chassis SE chassis SP3 Chassis Art Cool Type Parts List SP3 chassis Filter ASSEMBLY,AIR CleanerA3UC363FA0LMU360CE Parts List A3UH363FA0LMU360HE, A3UC363FA0LMU360CE CodeMay No A20474C

A3UH363FA0(LMU360HE), AMNC123DEA0(LMN120CE), AMNC093D4A0(LMN090CE), AMNH123DEA0(LMN120HE), A3UC363FA0(LMU360CE) specifications

LG Electronics is renowned for its innovation in the home appliance sector, particularly in air conditioning systems. Among its diverse range, the AMNC123APM0, A3UC363FA0, AMNH123DEA0, AMNC093D4A0, and AMNC123DEA0 model series stand out for their advanced features and energy efficiency.

The AMNC123APM0, also referred to as LMAN120CNS, offers a powerful air conditioning solution ideal for medium to large spaces. Featuring a sleek design, it combines aesthetics with functionality. This model utilizes LG's inverter technology, which helps maintain a consistent temperature while significantly reducing energy consumption. Additionally, it comes equipped with a dual inverter compressor that operates quietly, making it perfect for residential settings.

The A3UC363FA0, or LMU360CE, is another standout model that caters to the installation needs of multi-zone systems. Its flexibility allows users to connect multiple indoor units, ensuring efficient air distribution across different spaces. This model also features advanced filtration systems that improve indoor air quality by reducing allergens and other harmful particles.

AMNH123DEA0, branded as LMN120HE, introduces enhanced energy efficiency through its intelligent energy management systems. This unit is designed with user-friendly controls and smart technology to optimize performance based on user preferences. Its compact design makes it suitable for smaller spaces while still delivering powerful cooling and heating functions.

The AMNC093D4A0, known as LMN090CE, is perfect for residential applications where space is a consideration. It boasts a high SEER (Seasonal Energy Efficiency Ratio) rating, indicating low energy consumption while still providing optimal cooling. The model is equipped with a variety of operational modes, including dehumidification and fan-only options.

Finally, the AMNC123DEA0, or LMN120CE, rounds out this impressive series by offering versatile installation options and silent operation. This model is particularly noted for its robust cooling capabilities and ease of maintenance, ensuring that homeowners can enjoy year-round comfort with minimal disruption.

In summary, LG Electronics has blended efficiency, performance, and design in its latest air conditioning models. With features like inverter technology, multi-zone capabilities, advanced filtration, and quiet operation, these systems cater to modern home cooling and heating requirements while promoting energy conservation. As such, they represent a significant leap in HVAC technology, providing reliable comfort and improved indoor air quality.