If the appliance is on pause at the time set by the timer, the pause continues.

Off-Timer <=> On-Timer Operation

When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is carried out according to the set time.

Sleep Timer Operation

When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appli- ance operation, the operation of the appliance stops.

While the appliance is on pause, the sleep timer mode cannot be input.

While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature increases by 1°C(33.8°F). After another 30 min elapse, it increases by 1°C(33.8°F) again.

When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the low.

When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to the medium.

Chaos Swing Mode

By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are fixed to the desired direction.

While in Chaos Swing mode, the angles of cooling and heating cycle operations are different.

Chaos Natural Wind Mode

When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air- flow mode is operated for 2~15 sec. randomly by the Chaos Simulation.

Jet Cool Mode Operation

While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.

In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.

In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C(64.4°F).

When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.

When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then operated in order that the air outflow could reach further.

Auto Restarting Operation

When the power is restored after a sudden power failure while in appliance operation, the mode before the power failure is kept on the memory and the appliance automatically operates in the mode on the memory.

Service Manual 43

Image 43
Contents Outdoor Unit A3UH363FA0LMU360HE A3UC363FA0LMU360CE Indoor Unit Room Type Art Cool TypeTable of Contents Indoor Unit Model Number NomenclatureOutdoor Unit Combination table Symbols Used in this ManualControl box securely Cuit and breaker Safety PrecautionsInstallation Be sure not to do Be sure to follow the instructionOperation Do not place anything on the power cableBe cautious when unpacking Be sure the installation area does not deteriorate with ageHurricane arrives Nect the power supply cableDo not allow water to run into electric parts Smoke comes from productNot enter the product When the product is soakedInstall the drain hose to ensure that Keep level even when Installing the productNot use harsh detergents, sol OperationalAir flow Vents, etcDo not drink the water drained from the product Ly. Clean the filter every twoWhen cleaning or maintaining Do not step on or put anyting on the product. outdoor unitsIndoor Unit DimensionsSplit Type Indoor Outdoor Unit Indoor Unit Product SpecificationsModel A3UC363FA0LMU360CE A3UH363FA0LMU360HE Outdoor Unit Multiple piping modelsInstallation Parts InstallationInstallation Tools Select the best location Rooftop InstallationsOutdoor unit Multi Piping Type Piping length and elevationFixing Installation PlateStandard Type Drain hose junction Preparing work for Installation Artcool Type OnlyOpen panel front Remove cover pipe and cover sideDrive the fore plastic anchors into drilled points Sticking the installation guide map and fixing Indoor unitPut an Installation Guide Map on the desired surface Drill a hole in the wallFlaring work Flaring Work and Connection of PipingCheck Connecting the PipingIndoor Wrap the insulation material around the connecting por- tion For left rear piping Plastic bands Insulation material Connection Indoor Drive two screws Panel AssemblyArt Cool Type onlyBad case Good caseRemote Control Preparationoptional Outdoor unit OutdoorConnect the cable to the Indoor unit Connecting the Cable between Indoor Unit and Outdoor UnitOutdoor unit Connect the cable to the Outdoor unitHow to connect wiring to the terminals Connection method of the connecting cableExampleConnect the cable to the indoor unit To check the drainage Checking the drainageDrain piping Forming the piping Leakage test Air Purging and EvacuationChecking method PreparationEvacuation Repeat evacuation procedure for each indoor unitFinishing the job Additional ChargingSplit, Art Cool Type Test RunningOperation Cooling Mode OperationSoft Dry Operation Mode Heating Mode OperationFuzzy Operation Defrost ControlHeatingFuzzy Operation for Cooling Fuzzy Operation for Dehumidification On-Timer OperationOff-Timer Operation Airflow Speed SelectionChaos Natural Wind Mode Off-Timer = On-Timer OperationSleep Timer Operation Chaos Swing ModeBuzzer Sounding Operation Forced OperationSplit Type Indoor Unit Function of Indoor UnitDefrostDeice control Heating IndicatorArt Cool Type Indoor Unit OperationFunction of Outdoor Unit Cooling Model , Heat Pump Model Remote Control Operation15 2nd F Button To remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover To remove the Control Box Before removing the Turbo Fan To remove the EvaporatorTo remove the Motor Electronic Control Device Schematic DiagramSplit Type Outdoor Outdoor Unit Schematic Diagram Art Cool Type Indoor Unit Wiring DiagramBottom View Components LocationsArt Cool Type Schematic Diagram Component side Solder side A3UC363FA0LMU360CE Troubleshooting GuideRefrigeration Cycle Diagram A3UH363FA0LMU360HESelf-diagnosis Function Indoor ErrorOutdoor Error Error IndicatorTrouble analysis Cycle Troubleshooting GuideProcedure Specification Remedy Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller Check Point Comp. on Comp. OFF Compressor/Outdoor Fan are dont operateNector Trouble 4 When indoor Fan does not operateTroubleshooting Guide Indoor inlet pipe sensor Error CodeCheck Point Indoor air sensorCommunication line is shorted at GND Power input AC 230V.Outdoor, IndoorError Title Cause of error Check point & Normal condition Pipe sensor Title Cause of error Check point & Normal conditionOutdoor air sensor Condensor pipe sensorWay Valve Liguid Side Way, 3-way ValveSet the liquid side valve to the closed position ProcedurePumping down Air purging of the charge hoseEvacuation Mount the valve caps and the service port capsAll amount of refrigerant leaked Connect the gauge to the charging cylinder Mount the valve stem nuts and the service port nutGas Charging After EvacuationS4, SE chassis Exploded View & Replacement Parts ListS4 chassis SE chassis Parts List S4, SE chassisLMN090HE SP3 Chassis Art Cool Type Filter ASSEMBLY,AIR Cleaner Parts List SP3 chassisA3UC363FA0LMU360CE Code Parts List A3UH363FA0LMU360HE, A3UC363FA0LMU360CEMay No A20474C

A3UH363FA0(LMU360HE), AMNC123DEA0(LMN120CE), AMNC093D4A0(LMN090CE), AMNH123DEA0(LMN120HE), A3UC363FA0(LMU360CE) specifications

LG Electronics is renowned for its innovation in the home appliance sector, particularly in air conditioning systems. Among its diverse range, the AMNC123APM0, A3UC363FA0, AMNH123DEA0, AMNC093D4A0, and AMNC123DEA0 model series stand out for their advanced features and energy efficiency.

The AMNC123APM0, also referred to as LMAN120CNS, offers a powerful air conditioning solution ideal for medium to large spaces. Featuring a sleek design, it combines aesthetics with functionality. This model utilizes LG's inverter technology, which helps maintain a consistent temperature while significantly reducing energy consumption. Additionally, it comes equipped with a dual inverter compressor that operates quietly, making it perfect for residential settings.

The A3UC363FA0, or LMU360CE, is another standout model that caters to the installation needs of multi-zone systems. Its flexibility allows users to connect multiple indoor units, ensuring efficient air distribution across different spaces. This model also features advanced filtration systems that improve indoor air quality by reducing allergens and other harmful particles.

AMNH123DEA0, branded as LMN120HE, introduces enhanced energy efficiency through its intelligent energy management systems. This unit is designed with user-friendly controls and smart technology to optimize performance based on user preferences. Its compact design makes it suitable for smaller spaces while still delivering powerful cooling and heating functions.

The AMNC093D4A0, known as LMN090CE, is perfect for residential applications where space is a consideration. It boasts a high SEER (Seasonal Energy Efficiency Ratio) rating, indicating low energy consumption while still providing optimal cooling. The model is equipped with a variety of operational modes, including dehumidification and fan-only options.

Finally, the AMNC123DEA0, or LMN120CE, rounds out this impressive series by offering versatile installation options and silent operation. This model is particularly noted for its robust cooling capabilities and ease of maintenance, ensuring that homeowners can enjoy year-round comfort with minimal disruption.

In summary, LG Electronics has blended efficiency, performance, and design in its latest air conditioning models. With features like inverter technology, multi-zone capabilities, advanced filtration, and quiet operation, these systems cater to modern home cooling and heating requirements while promoting energy conservation. As such, they represent a significant leap in HVAC technology, providing reliable comfort and improved indoor air quality.