LG Electronics AMNC093D4A0(LMN090CE) Panel AssemblyArt Cool Type only, Drive two screws

Page 26

Flaring Work and Connection of Piping

Panel Assembly(Art Cool Type only)

1.First, Check the side cover assembly exactly, Fix power cord in the bottom groove of cover side

left.

2.Assemble connecting lead wire with controller and first fix the upper part of panel front, then

match the lower part of panel front

Panel Front

Connector

3. Drive two screws.

26Multi type Air Conditioner

Image 26
Contents Indoor Unit Room Type Art Cool Type Outdoor Unit A3UH363FA0LMU360HE A3UC363FA0LMU360CETable of Contents Outdoor Unit Model Number NomenclatureIndoor Unit Symbols Used in this Manual Combination tableBe sure not to do Be sure to follow the instruction Safety PrecautionsInstallation Control box securely Cuit and breakerBe sure the installation area does not deteriorate with age Do not place anything on the power cableBe cautious when unpacking OperationSmoke comes from product Nect the power supply cableDo not allow water to run into electric parts Hurricane arrivesInstalling the product When the product is soakedInstall the drain hose to ensure that Keep level even when Not enter the productVents, etc OperationalAir flow Not use harsh detergents, solDo not step on or put anyting on the product. outdoor units Ly. Clean the filter every twoWhen cleaning or maintaining Do not drink the water drained from the productSplit Type Indoor DimensionsIndoor Unit Outdoor Unit Product Specifications Indoor UnitOutdoor Unit Multiple piping models Model A3UC363FA0LMU360CE A3UH363FA0LMU360HEInstallation Tools InstallationInstallation Parts Outdoor unit Rooftop InstallationsSelect the best location Piping length and elevation Multi Piping TypeFixing Installation PlateStandard Type Remove cover pipe and cover side Preparing work for Installation Artcool Type OnlyOpen panel front Drain hose junctionDrill a hole in the wall Sticking the installation guide map and fixing Indoor unitPut an Installation Guide Map on the desired surface Drive the fore plastic anchors into drilled pointsFlaring Work and Connection of Piping Flaring workIndoor Connecting the PipingCheck Wrap the insulation material around the connecting por- tion For left rear piping Plastic bands Insulation material Connection Indoor Panel AssemblyArt Cool Type only Drive two screwsGood case Bad caseRemote Control Preparationoptional Outdoor Outdoor unitConnecting the Cable between Indoor Unit and Outdoor Unit Connect the cable to the Indoor unitConnect the cable to the Outdoor unit Outdoor unitConnection method of the connecting cableExample How to connect wiring to the terminalsConnect the cable to the indoor unit Drain piping Checking the drainageTo check the drainage Forming the piping Preparation Air Purging and EvacuationChecking method Leakage testFinishing the job Repeat evacuation procedure for each indoor unitEvacuation Charging AdditionalTest Running Split, Art Cool TypeHeating Mode Operation Cooling Mode OperationSoft Dry Operation Mode OperationFuzzy Operation for Cooling Defrost ControlHeatingFuzzy Operation Airflow Speed Selection On-Timer OperationOff-Timer Operation Fuzzy Operation for DehumidificationChaos Swing Mode Off-Timer = On-Timer OperationSleep Timer Operation Chaos Natural Wind ModeForced Operation Buzzer Sounding OperationFunction of Indoor Unit Split Type Indoor UnitOperation IndicatorArt Cool Type Indoor Unit DefrostDeice control HeatingFunction of Outdoor Unit 15 2nd F Button Remote Control OperationCooling Model , Heat Pump Model Disassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover To remove the Control Box To remove the Motor To remove the EvaporatorBefore removing the Turbo Fan Split Type Schematic DiagramElectronic Control Device Outdoor Outdoor Unit Schematic Diagram Wiring Diagram Art Cool Type Indoor UnitComponents Locations Bottom ViewArt Cool Type Schematic Diagram Component side Solder side A3UH363FA0LMU360HE Troubleshooting GuideRefrigeration Cycle Diagram A3UC363FA0LMU360CEError Indicator Indoor ErrorOutdoor Error Self-diagnosis FunctionCycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Procedure Specification RemedyProduct doesnt operate with the remote controller Compressor/Outdoor Fan are dont operate Check Point Comp. on Comp. OFFTrouble 4 When indoor Fan does not operate NectorTroubleshooting Guide Indoor air sensor Error CodeCheck Point Indoor inlet pipe sensorPower input AC 230V.Outdoor, Indoor Communication line is shorted at GNDError Title Cause of error Check point & Normal condition Condensor pipe sensor Title Cause of error Check point & Normal conditionOutdoor air sensor Pipe sensorWay, 3-way Valve Way Valve Liguid SideAir purging of the charge hose ProcedurePumping down Set the liquid side valve to the closed positionAll amount of refrigerant leaked Mount the valve caps and the service port capsEvacuation After Evacuation Mount the valve stem nuts and the service port nutGas Charging Connect the gauge to the charging cylinderExploded View & Replacement Parts List S4, SE chassisLMN090HE Parts List S4, SE chassisS4 chassis SE chassis SP3 Chassis Art Cool Type Parts List SP3 chassis Filter ASSEMBLY,AIR CleanerA3UC363FA0LMU360CE Parts List A3UH363FA0LMU360HE, A3UC363FA0LMU360CE CodeMay No A20474C