Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'leau.
Test gauge connections are provided on the front of the millivolt gas control valve (identified OUT for the manifold side and IN for inlet pressure. A 1/8" NPT test gauge connection is provided on the electronic gas control valve adjacent to the outlet to the main burner.
Minimum inlet gas pressure to these appliances is
5.0incheswatercolumn(1.24kPa)fornaturalgas and11incheswatercolumn(2.74kPa)forpropane for the purpose of input adjustment.
Maximum inlet gas supply pressure to these appli- ances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.
Theappliancemustbeisolatedfromthegassupply piping system (by closing its individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa).
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Any safety guard or screen removed for servicing the appliance must be replaced prior to operating the appliance.
WARNING
B-Vent appliances are not designed to operate in negatively pressured environments (pressure within the homeislessthanpressuresoutside). Significant negatively pressured environments caused by weather, home design, or other devices may impact the operation of these appli- ances. Negativepressuresmayresult in poor flame appearance, sooting, damage to property and/or severe personal injury. Do not operate these appliances in negatively pressured environments.
Carbon Monoxide Poisoning: Early signs of carbonmonoxidepoisoningaresimilartotheflu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly.
WARNING
Failure to comply with the installa- tion and operating instructions pro- vided in this document will result in an improperly installed and operat- ing appliance, voiding its warranty. Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appliance can cause serious injury or death form fire, burns, explosion or carbon monoxide poisoning.
WARNING
Children and adults should be alerted to the hazards of high sur- face temperatures. Use caution around the appliance to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.
WARNING
Do not place clothing or other flam- mable materials on or near this appliance.
AVERTISSEMENT
Surveiller les enfants. Garder les vêtements, les meubles, l'essence ou autres liquides à vapeur inflam- mables lin de l'appareil.
OPERATION AND CARE OF YOUR APPLIANCE
Appliance operation may be controlled through a remotely located optional wall switch. Separate switches may provide independent control for the remote controlled fireplace operation (op- tional equipment).
In lieu of remote or remote wall switch operation, the appliance must be operated directly through the controls located on the front of the valve located within the control compartment which is located behind the control compartment access panel below the appliance front glass enclosure panel. See Figure 1.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Control | |
Compartment | Millivolt |
Access Panel |
| Gas Valve |
| Piezo Igniter |
Figure 1 | |
Gas Controls/Control Compartment Access
The gas controls can be found behind the control compartment access panel. To open the control compartment access panel, actuate the spring loaded magnetic catches securing the panel. First, gently depress the upper right top corner of the panel until the magnet catch "pops" the door free. Then, gently pulling the panel forward, disengage the left magnet catch and allow the panel to swing down to open.
Operation of millivolt and electronic gas control systems are different. Before lighting and op- erating your appliance determine if you have a millivolt or electronic appliance. See Figure 1 for access to the control compartment.
Millivolt appliances will be fitted with the gas control valve shown in Figure 3 on Page 4.
Appliances with electronic systems will be fit- ted with the electronic valve shown in Figure 2 on Page 4.
Familiarize yourself with the gas control valve that your appliance uses.
Millivolt Appliances -
To light millivolt appliances refer to the detailed lighting instructions found on Page 18 (English) and Page 19 (French). Millivolt appliance lighting instructions may also be found on the pull-out lighting instruction labels attached to the gas control valve. Refer to Figure 3 on Page
4for the location of the piezo Igniter.
Millivolt appliances may be fitted with an optional burner ON/OFF Rocker Switch. The optional ON/ OFF Rocker switch will be installed in the bracket just beneath the gas control valve. Once the pilot is lit, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions.
3