If your millivolt appliance is equipped with an optional remote wall switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control.
Electronic Appliances -
To light electronic appliances refer to the detailed lighting instructions found in both English and French on Pages 20 and 21 of these instruc- tions respectively. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.
If your electronic appliance is not equipped with a wall switch or remote control, the main
Variable Flame Height Adjustment | Inlet Pressure Port | |||
| Manifold Pressure Port | |||
|
|
| OUT | IN |
TPTH |
|
|
|
|
T | I | H |
|
|
P |
|
| OFF |
|
|
|
| P | |
|
|
|
| |
|
|
|
| I |
TH | L OW |
| L | |
it | O | |||
|
|
| NO | T |
|
|
|
| |
| P |
|
|
|
| LI |
|
|
|
| TO |
|
|
|
|
|
|
| Piezo Igniter |
|
|
|
| Main Gas |
|
|
|
| Control Knob |
| Piezo Igniter |
| Optional Burner ON/OFF Rocker Switch Location | |
|
|
|
| (One of Two Places) |
Figure 3 |
|
|
| SIT Millivolt Gas Valve |
burner must be turned off and on with the gas control switch. Toggle the switch from ON to OFF to operate the main burner .
Manifold Pressure Port | ON/OFF Switch | ||
CONTROL | OFF ON | N | Inlet |
|
| I | Pressure |
IGNITER |
|
| |
|
| Port | |
|
|
| |
|
| ISP |
|
|
|
| Electronic |
|
|
| Gas Control |
|
|
| Valve |
Honeywell Electronic Gas Valve | |||
Figure 2 |
|
|
|
Variable Flame Height Adjustment ( Millivolt Appliances only)
1.All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation. Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob located on the front of the valve (refer to Figure 3).
2.When lit for the first time, this appliance will emit a slight odor for an hour or two. This is due to the
3.Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean.
4.Always turn off gas to the pilot (millivolt appliances) before cleaning. Before
5.Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
6.Remember, Millivolt appliances have a continuous burning pilot flame. Exercise cau- tion when using products with combustible vapors.
7.Clean the front glass enclosure only when necessary. Wipe surface with clean, dampened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface.
WARNING
Do not use abrasive cleaners. Never clean the glass when it is hot.
CAUTION
Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use.
4